Installation Procedure
It is essential to observe minimum wall mounting clearances, as per
Fig. 1
overleaf.
The appliance should be fitted horizontally, with the cable entry at the top
and grille at the bottom. It must be mounted not less than 1.8 metres above
the floor with a clearance of at least 600mm to any shelf or projecting
surface below the heater and not less than 300mm below the ceiling or
other projecting surface. It must also be not less than 250mm from an
adjacent projecting surface. For most effective heating performance, the
heater should be mounted at the minimum height:
i.e. 1.8 metres above the floor.
Care must be taken to ensure that when in use, the air stream is not
obstructed by a high shelf or cabinet.
The appliance is secured to the wall with three screws, two through keyhole
slots and one through a centrally positioned lower hole to hold the appliance
firmly in position (see
Fig. 2
).
1.
Remove the top cover from the appliance by removing the two
screws securing the top cover and hinging it back.
2.
Mark the position of the keyhole slots on the wall and drill and plug
for the two suitable screws.
3.
Partially insert the two screws, then hang the appliance on these
screws and mark the position of the lower centrally positioned screw.
4.
Remove the appliance and drill and plug for the third screw.
5.
Remount the appliance on the wall, ensure that it is horizontal and
fix in position by tightening all three screws.
6.
Feed the supply cord or wires through the inlet at the top rear
of the
appliance leaving sufficient free length to connect to the terminal
block.
7.
Make electrical connections to the terminal block ensuring that the
live connection is made to the terminal marked ‘L’ and the neutral
connection to the terminal marked ‘N’ (see
Fig. 2
exploded view).
8.
Operate the selector switch to provide either 1kW or 2kW output.
9.
Replace the top cover and screws.
The appliance is now ready for use and the electricity supply can be
reinstated.
Fig. 2
Cleaning and User Maintenance
WARNING: BEFORE UNDERTAKING CLEANING OR MAINTENANCE
WORK ON THE APPLIANCE IMMEDIATELY DISCONNECT THE
ELECTRICITY SUPPLY BY SWITCHING OFF AT THE ADJACENT
DOUBLE POLE SWITCH.
The outside can be cleaned by wiping it over with a soft damp cloth and
then dried. Do not use abrasive cleaning powders or furniture polish as
this can damage the surface finish.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should not be
disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for
recycling advice in your country.
After Sales Service
If this product appears damaged when first received or does not
function correctly contact us by e-mail customer.services
@credaheating.co.uk or ring 0844 879 35 88 and we will be able to
help.
For ROI please phone 018424833.
Do Not Return the product in the first instance as this may delay us
providing you with a satisfactory service.
ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE WARRANTY.
Your product is guaranteed for one year from the date of purchase. Within
this period, we undertake to repair this product free of charge provided it
has been installed and operated in accordance with these instructions.
Should you require assistance with this product please go to
www.credaheating.co.uk
and click on “Customer Support” or e-mail us
at
Alternatively ring our contact centre on 0844 879 35 88 (UK only). This is
a Lo-call no. from a BT landline - other providers including mobile
phones may charge you more. For ROI please phone 01 842 4833.
To assist you, we will need the following information: model number and
serial no (these can be found on the product), nature of the fault and date
of purchase.
Please retain your receipt as proof of purchase.
Your
rights under this guarantee are additional to your statutory rights, which
in turn are not affected by this guarantee.
Controls
The heater is fitted with a pull cord
operated ON/OFF switch, a
thermostat, a cut-out, and a thermal
fuse link.
The heater has an internal
adjustable thermostat which can
be adjusted by installer (i.e. the top
cover has to be removed), see
Fig.
3
for controls details with cover
removed.
Temp. range 18°C - 32°C.
Fig. 3
WIRING DIAGRAM
CREDA HEATING
MILLBROOK HOUSE
GRANGE DRIVE
HEDGE END
SOUTHAMPTON
SO30 2DF
1000W
1000W
M
95
2 No.
Slots
Keyhole
188
116
22
72
Exploded view of
Terminal Block
Terminal
Block
L
N
Cable entry
Hole for
3rd Screw
L
C
Mains Cable
'Internal' Adjustable
Thermostat Knob
Selector
Switch
L
N
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC)
EN55014, EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
[c] GDC Group Ltd,
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of GDC Group
Ltd..
TEL: 0844 879 3588
FAX: 0844 879 3583
WEBSITE: www.credaheating.co.uk
ROI: 01 842 4833