background image

Create Flow s.r.o. 

Tel: 00420 722 712 652     

[email protected]

     

www.createflow.cz

     

 

Knob: 

Manually adjust the speed. 

Current regulation: 

Potentiometer used to adjust the size of the drive motor drive current, 

clockwise increase, counterclockwise decrease. 

Subdivision adjustment: 

1: OFF, 2: ON, 3: ON 

J2: communication interface 

For the TTL level, corresponding to the microcontroller serial port 1 foot 

VCC, 2 feet TXD, 3 feet RXD, 4 

When the foot is GND, when connecting the computer, it can be equipped 

with USB to serial cable. 

J3: start and stop, the direction of the interface 

The middle pin is a common terminal, short-circuited with "left", then the 

motor runs counterclockwise, short-circuit with "right" 

Motor running clockwise, you can connect the button switch control. 

J4: speed control knob interface 

Can be connected by external speed control knob

 

Содержание PMD07

Страница 1: ...Create Flow s r o Tel 00420 722 712 652 info createflow cz www createflow cz PMD07 motherboard Manual ...

Страница 2: ...3 PMD07 technical indicators 5 4 PMD07 main board features and features 5 6 product maintenance 7 7 warranty and after sales service 7 1 PMD07 motherboard introduction PMD07 board can control 57 stepper motors is a highly integrated and reliable two phase stepper motor driver board start and stop by the external control and direction 0 9 inch OLED blue screen shows the operating status ...

Страница 3: ...terface Motor Interface As shown above the motor interface corresponds to the green line red line yellow line and blue line of the stepper motor from right to left DC Power Interface DC 24V power supply J5 OLED display interface Connect the OLED display 0 9 the display content is speed running stop status display direction display as shown below ...

Страница 4: ...r the TTL level corresponding to the microcontroller serial port 1 foot VCC 2 feet TXD 3 feet RXD 4 When the foot is GND when connecting the computer it can be equipped with USB to serial cable J3 start and stop the direction of the interface The middle pin is a common terminal short circuited with left then the motor runs counterclockwise short circuit with right Motor running clockwise you can c...

Страница 5: ... 3A power 40W Operating temperature 0 40 Working environment the environment humidity can not be condensation can not have water droplets can not be placed on the side of other heating equipment to avoid dust oil mist corrosive gas and strong vibration place 4 PMD07 main board features and features Power supply voltage DC 9 30 V the maximum output current of 3 3A 232 communication remote control O...

Страница 6: ...Create Flow s r o Tel 00420 722 712 652 info createflow cz www createflow cz 5 PMD07 installation dimensions Unit mm ...

Страница 7: ... be kept clean and dry If the roller surface is not clean it will increase the hose wear and tear reduce hose life and lead to premature damage to the wheel If there is any liquid on it wipe it off with cloth as soon as possible If it is wet for a long time it will cause damage to the roller 7 warranty and after sales service Product warranty for one year excluding pump tube during the warranty pe...