![CREATCOM TB21 Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/creatcom/tb21/tb21_user-manual_2680364059.webp)
U ser Manual
TB2I
C O PYRIG H T ©2016 C reatC omm Technology
8
Logout
C lick the logout button, it will logout the device and return to the login page.
9
FAQ
1.
The device cannot be started after power on.
①
The Ethernet cable between the device and the PO E adaptor is more than 40 meters
long.
②
The Ethernet cable quality is not good enough, and it should be C at 5e or even C at 6
cable.
③
The RJ-45 plugs are not well connected.
2.
Forgot the IP address of the device.
Please manually push the Reset button for 5~10 seconds and wait 2 or 3 minutes, then
the user can log in the device by typing the default IP address
192.168.1.36/192.168.1.35.
3.
H ow to modify the IP address of the device?
Please open the device page, followed by click N etwork - > interfaces - > select Edit
button of the LAN interface - >C ommon C onfiguration - >G eneral S etup ->IPv4 address;
here you can set the IP address according to your own needs. But you should ensure the
IP you edit is different with other devices, so as to avoid IP address conflict. <
C hapter
7.1.1
>
4.
The signal level or the wireless TX/RX rate is low
①
There is a large bunker between C lient and access point. Please remove or bypass
the bunker.
②
The scale plate of the client is not directed at the access point. Please adjust the
client and access point.
③
S witch to other wireless channel cause there are much interferences in this channel.