AC Repair and Adjustment Procedures
FRP 13: Boundary Scan Cable/Wire Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
95
Wire Installation
1.
Determine the location for the replacement boundary scan pin
connector(s).
2. Label both ends of the replacement clock wire.
3. Route the replacement wire assembly in the wiremat.
4.
Ensure that the rail connector where the wire assembly connects is loose
and accessible through the card cage. If it is not, complete
through
of the “Wire Removal” portion of this procedure.
5.
Perform the following steps to insert each replacement wires in the rail
connector:
a. Position the 2-pin connector above the appropriate pin slot in the rail
connector. (Pin slot 1 is marked with red in most cases. Pin slot 2 is
directly across from pin slot 1.) Ensure that the 2-pin connector is
oriented with the pin lock (wavy side) toward the outside of the
connector as shown in
, on Page 98, shows the
process using a wire insertion rod.)
b. Use your fingers or an appropriate tool (such as tweezers, hemostats,
or a wire insertion tool) to gently push the clock pin connector into the
pin slot. Ensure that you do not damage the wires.
Figure 42. Wire Insertion
CAUTION
Ensure that you do not damage the wires when you
insert the connector.
Move the connector
to the appropriate
location.
Gently push the
connector into rail
connector.
Press the top of the
connector to fully
seat it in the rail
connector.
Rail Connector
Step 5