background image

3

Congratulations

!

You are now the proud owner of the Crate RFX120 three-channel guitar amplifier

with Advanced Digital Signal Processing. This rugged amplifier combines outstanding
features with serious clean and distorted sounds. Dual DSP controls provide 15 “Multi”
effects and 15 Delay effects which can be combined for a wide variety of sounds. The
Save/Tap button allows you to manually set the tempo of many of the effects and to
save new DSP presets in the amplifier’s non-volatile memory. A separate Reverb
control adds even more to the array of effects. Front panel RCA CD Input jacks
allow you to play along with your favorite CD or tape. The rear panel Insert Jack allows
you to connect your effects for greater flexibility. Channel switching and DSP may be
controlled by means of a footswitch, which also allows access to two DSP presets on
each of the three channels. The top-mounted electronic tuner lets you get tuned and
stay in tune any time the amplifier is on.

Like all Crate products, your RFX120 amplifier is designed by musicians, and built

using only the best components. Extensive testing confirms that this amplifier is the
absolute best it can be.

In order to get the most out of your new amplifier, we strongly suggest that you read

the information contained in this guide before you begin playing.

And  thank you for choosing 

C

CR

RA

AT

TE

E

.

IMPORTANT SAFETY INSTRUCTIONS

READ, FOLLOW, HEED, AND KEEP ALL INSTRUCTIONS AND WARNINGS.

DO NOT OPERATE NEAR ANY HEAT SOURCE AND DO NOT BLOCK ANY VENTILATION OPENINGS ON THIS APPARATUS. FOR PROPER OPERATION,

THIS UNIT REQUIRES 3” (75mm) OF WELL VENTILATED SPACE AROUND HEATSINKS AND OTHER AIR FLOW PROVISIONS IN THE CABINET.

DO NOT USE THIS APPARATUS NEAR SPLASHING, FALLING, SPRAYING, OR STANDING LIQUIDS.

CLEAN ONLY WITH LINT-FREE DAMP CLOTH AND DO NOT USE CLEANING AGENTS.

ONLY CONNECT POWER CORD TO A POLARIZED, SAFETY GROUNDED OUTLET WIRED TO CURRENT ELECTRICAL CODES AND COMPATIBLE WITH

VOLTAGE, POWER, AND FREQUENCY REQUIREMENTS STATED ON THE REAR PANEL OF THE APPARATUS.

PROTECT THE POWER CORD FROM DAMAGE DUE TO BEING WALKED ON, PINCHED, OR STRAINED.

UNPLUG THE APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME.

ONLY USE ATTACHMENTS, ACCESSORIES, STANDS, OR BRACKETS SPECIFIED BY THE MANUFACTURER FOR SAFE OPERA-

TION AND TO AVOID INJURY.

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK OR FIRE, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.

SERVICE MUST BE PERFORMED BY QUALIFIED PERSONNEL.

OUR AMPLIFIERS ARE CAPABLE OF PRODUCING HIGH SOUND PRESSURE LEVELS. CONTINUED EXPOSURE TO HIGH SOUND PRESSURE LEVELS

CAN CAUSE PERMANENT HEARING IMPAIRMENT OR LOSS. USER CAUTION IS ADVISED AND EAR PROTECTION IS RECOMMENDED IF UNIT IS

OPERATED AT HIGH VOLUME.

• WARNING: THIS UNIT REQUIRES A SAFETY GROUNDED OUTLET WIRED TO CURRENT ELECTRIC CODES HAVING THE LINE SUPPLY VOLTAGE,

POWER, AND FREQUENCY IDENTIFIED ON THE REAR OF THE UNIT. THE OUTLET MUST REMAIN ACCESSIBLE TO DISCONNECT THE UNIT IF A

FAULT SHOULD ARISE WHILE IN USE. THIS UNIT SHOULD BE UNPLUGGED WHEN NOT IN USE.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOIS-
TURE. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT
REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

"IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL"

“ES NECESARIO QUE EL USUARIO SE REFIERA AL MANUAL DE INSTRUCCIONES.”

"REFERREZ-VOUS AU MANUAL D'UTILISATION"

EXPLANATION OF GRAPHICAL SYMBOLS:

EXPLICACION DE SIMBOLOS GRAFICOS:

EXPLICATION DES SYMBÔLES GRAPHIQUES:

"DANGEROUS VOLTAGE"

“VOLTAJE PELIGROSO”

"DANGER HAUTE TENSION"

=

=

PRECAUCION

RIESGO DE CORRIENTAZO

NO ABRA

PRECAUCION: PARA REDUCIR EL RIESGO DE INCENDIOS O DESCARGAS
ELECTRICAS, NO PERMITA QUE ESTE APARATO QUEDE EXPUESTO A LA
LLUVIA O LA HUMEDAD. PARA DISMINUOIR EL RIESGO DE CORRIENTAZO.
NO ABRA LA CUBIERTA. NO HAY PIEZAS ADENTRO QUE EL USARIO PUEDO
REPARAR DEJE TODO MANTENIMIENTO A LOS TECHNICOS CALIFICADOS.

ATTENTION

RISQUE D'ELECTROCUTION

NE PAS OUVRIR

ATTENTION: PROTÉGEZ CET APPAREIL DE LA PLUIE ET DE L'HUMIDITÉ
AFIN D'ÉVITER TOUT RISQUE D'INCENDIE OU D'ÉLECTROCUTION. POUR
REDUIRE D'ELECTROCUTION NE PAS ENLEVER LE COUVERCLE. AUCUNE
PIECE INTERNE N'EST REPRABLE PAR L'UTILISATEUR. POUR TOUTE
REPARATION, S'ADRESSER A UN TECHNICIEN QUALIFIE.

Guitar Amplifier

Содержание RFX120 RetroFex

Страница 1: ...Guitar Amplifier with Digital Effects User s Guide...

Страница 2: ...41 Fax 314 569 0175 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable...

Страница 3: ...BEING WALKED ON PINCHED OR STRAINED UNPLUG THE APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME ONLY USE ATTACHMENTS ACCESSORIES STANDS OR BRACKETS SPECIFIED BY THE MANUFACTUR...

Страница 4: ...active only when the Solo Rhythm Clean switch 13 is depressed 7 RHYTHM LED This LED illuminates when the Rhythm channel is selected 8 GAIN Use this control to adjust the amount of distortion produced...

Страница 5: ...atus indicator for certain DSP activities see page 8 NOTE For some of the DSP effects the Save Tap LED remains illuminated The Save Tap LED does not illuminate when the DSP knobs are set to the Bypass...

Страница 6: ...peaker is connected 29 DSP A B FOOTSWITCH Use this jack to connect one of the footswitch cables to the three button footswitch supplied This allows you to select between two presets for each of the th...

Страница 7: ...d 05 1 second Phaser HI Phaser w high feedback speed 2 cycle tap tap period 05 1 second Vibrato LO Vibrato w low depth speed 1 cycle tap tap period 05 1 second Vibrato MID Vibrato w medium depth speed...

Страница 8: ...The Save Tap button is used to set the tempo of an effect by pressing it twice within a one second time frame The time between the two taps sets the timing of the effect If the Save tap button is pres...

Страница 9: ...accessible when the footswitch is connected to the amplifier When the footswitch is not connected only DSP Bank A is accessable 3031613 EXTENSION SPEAKER INSERT FOOTSWITCH DSP BANK A BANK B CHANNEL CL...

Страница 10: ...E SINGLE TAPE TAPE REVERB REVERB MULTI MULTI DELAY DELAY DSP DSP SAVE TAP SAVE TAP CHORUS CHORUS FLANGE FLANGE PHASER PHASER VIB VIB O O T T R R EFX EFX ECHO ECHO SINGLE SINGLE TAPE TAPE REVERB REVERB...

Страница 11: ...APE TAPE REVERB REVERB MULTI MULTI DELAY DELAY DSP DSP SAVE TAP SAVE TAP CHORUS CHORUS FLANGE FLANGE PHASER PHASER VIB VIB O O T T R R EFX EFX ECHO ECHO SINGLE SINGLE TAPE TAPE REVERB REVERB MULTI MUL...

Страница 12: ...CHO SINGLE SINGLE TAPE TAPE RHYTHM SOLO VOLUME SHAPE GAIN LOW MID HIGH LEVEL LOW MID HIGH LEVEL GAIN REVERB REVERB MULTI MULTI DELAY DELAY SOLO RHYTHM CLEAN SOLO RHYTHM CLEAN DSP DSP SAVE TAP SAVE TAP...

Страница 13: ...LE TAPE TAPE RHYTHM SOLO VOLUME SHAPE GAIN LOW MID HIGH LEVEL LOW MID HIGH LEVEL GAIN REVERB REVERB MULTI MULTI DELAY DELAY SOLO RHYTHM CLEAN SOLO RHYTHM CLEAN DSP DSP SAVE TAP SAVE TAP CHORUS CHORUS...

Страница 14: ...TI DELAY DELAY DSP DSP SAVE TAP SAVE TAP CHORUS CHORUS FLANGE FLANGE PHASER PHASER VIB VIB O O T T R R EFX EFX ECHO ECHO SINGLE SINGLE TAPE TAPE REVERB REVERB MULTI MULTI DELAY DELAY DSP DSP SAVE TAP...

Страница 15: ...RB BUFFER MIX AMP CLEAN DAMPING CIRCUIT POWER AMP EXTENSION SPEAKER SPEAKERS SOLO RHYTHM INSERT SOLO GAIN SOLO LEVEL SWITCHING CIRCUIT RHYTHM LEVEL SOLO RHYTHM RHYTHM GAIN RTHM SOLO SOLO RHYTHM MID LO...

Страница 16: ...Hz Mid Control 15dB range 800Hz High Control 40dB range 10kHz Power Requirements 120 VAC 60Hz 95VA 100 115VAC 50 60Hz 95VA 230VAC 50 60Hz 95VA Size and Weight 21 H x 27 1 2 W x 11 1 4 D 50 lbs The RFX...

Отзывы: