background image

Page 14

6" & 8" Bear Cat Chipper Operator’s Manual

Handle pressurized hydraulic fluid carefully. Escaping

pressurized hydraulic fluid can have sufficient force to

penetrate your skin causing serious injury. This fluid may

also be hot enough to burn. Serious infection or reactions

can develop if proper medical treatment is not

administered immediately.

Premium hydraulic fluids containing high quality rust,

oxidation, and foam inhibitors are required. These include

premium turbine oils, API CD engine oils per SAE J183,

M2C33F or G automatic transmission fluids meeting

Allison C-3 or Caterpillar TO-2, and certain specialty

agricultural tractor fluids.

5.11  PUMP  COMPONENT  LOCA-

TIONS  (MODELS  72620  &  74824)

5.12 HYDROSTATIC PUMP START UP

PROCEDURE  (MODELS  72620  &

74824)

5.10  HYDRAULIC  FLUID  (MODELS

72620  &  74824)

Service and Maintenance

NOTE

A motor fitting may have to be loosened and oil bled to

remove air from the system (use same procedures as

steps 3-5).

    

 WARNING

Do not start engine unless pump is in neutral position on

the cable.

NOTE

Hydrostatic pressure controlled by the crossover relief

valve is factory set at 1750 PSI.

Follow this start-up procedure when starting a new

installation or when restarting an installation in which the

hydrostatic pump has been removed from the system.
1. Before starting the hydrostatic pump, make sure all

system components (reservoir, fittings, etc.) are clean.

2. Fill the reservoir with recommended hydraulic fluid, which

should be filtered before entering the reservoir.

3. The inlet line leading from the reservoir to the charge

pump must be filled before start-up. Loosen the fitting

on this inlet line until oil bleeds out.

4. Start the engine and run at the lowest possible RPM.

5. As air is purged from the unit, the oil level in the reser-

voir will drop and bubbles may appear in the fluid. Refill

the reservoir as necessary.

6. Run the unit and move the control arm in both direc-

tions for several minutes until any remaining air is purged

from the unit. Refill the reservoir as necessary.

7. Check to ensure feed roller stops when control arm is in

the neutral position.  Adjust the cable clevis or anchor if

the feed roller doesn't stop.

8. Shut down the engine, check for and correct any fluid

leaks, and check the reservoir level. Add fluid if neces-

sary. The hydrostatic pump is now ready for operation.

Fig. #9

Содержание 71620

Страница 1: ...Industries 237 12th St NW P O Box 849 West Fargo ND 58078 0849 701 282 5520 FAX 701 282 9522 www bearcatproducts com OWNER OPERATOR S MANUAL 6 and 8 Chipper Models 74824 8 24 HP Chipper with Hydrauli...

Страница 2: ...THER STATES OPERATING OUTDOOR POWER EQUIPMENT Under California Law and under the laws of several other states you are not permitted to operate an internal combustion engine using hydrocarbon fuels on...

Страница 3: ...misuse accidents or lack of proper maintenance This includes belts pulleys and chipper blades Regular routine maintenance of the unit to keep it in proper operating condition is the responsibility of...

Страница 4: ...LOCATIONS MODELS 72620 74824 9 SERVICE MAINTENANCE 10 5 1 SHARPENING CHIPPER BLADES 10 5 2 SETTING CHIPPER BLADE CLEARANCE 11 5 3ADJUSTING DRIVE BELTS 11 5 4 REPLACING DRIVE BELTS 12 5 5 CLEARING PLUG...

Страница 5: ...perator s Manual and on your machine to alert you to potential hazards Whenever you see this symbol read and obey the safety message that follows it Failure to obey the safety message could result in...

Страница 6: ...chine 8 Set up your work site so you are notendangeringtrafficandthepub lic Take great care to provide ad equate warnings 9 Ensure debris does not blow into traffic parked cars or pedestrians 10 Check...

Страница 7: ...ly when towing 1 7 BATTERY SAFETY 1 Improper use and care of the bat tery on electric start models can result in serious personal injury or property damage Always observe the following safety precauti...

Страница 8: ...m 6 Attach the blower discharge tube to the mounting flange on the chipper frame Half of the mounting clamp is already attached to the tube Slide the tube into the flange and tighten the bolts to secu...

Страница 9: ...urs Temperature under 60 F 3 amperes for 6 Hours 7 Place charged battery in battery box on chipper shred der 8 Remove key from engine ignition 9 Install the positive battery cable to the positive batt...

Страница 10: ...ve Belts and Shield Never remove shields when in use 5 Chipper Chute Feed materials to be chipped through the chute CAUTION The chipper rotor may continue to rotate even with the engine stopped Do not...

Страница 11: ...ear heavy boots gloves pants and shirt Use common sense and practice safety to protect yourself from branches sharp objects and other harmful objects 3 Depress foot clutch pedal down this will disenga...

Страница 12: ...SLOW position 2 Depress foot clutch pedal NOTE The heavy rotor will continue to turn for some time after the engine has been shut off You can tell that the rotor has stopped when no noise or machine v...

Страница 13: ...on 4 6 CONTROL ARM OPERATION MODELS 72620 74824 4 7 HYDRAULIC FEED COMPONENT LOCATIONS MODELS 72620 74824 WARNING Please read and follow all safety instructions in this manual Failure to operate the c...

Страница 14: ...n working on the rotor assembly use the lock mechanism at all times Remove plastic bearing cover under chipper chute There is a hole in the rotor jack shaft and a matching hole in the bracket mounted...

Страница 15: ...the anvil and use one of the other three edges Adjust for correct measurement Service and Maintenance 5 3 SETTING CHIPPER BLADE CLEARANCE 5 3 ADJUSTING DRIVE BELTS Check the condition of the drive bel...

Страница 16: ...needed Service and Maintenance 5 4 REPLACING DRIVE BELTS 5 5 CLEARING PLUGGED ROTOR Feeding too large or too much chipable material at once may plug the chipper To clear plugged rotor proceed as foll...

Страница 17: ...REPLACING RO TOR BEARINGS WARNING The rotor assembly has a lock mechanism When work ing on the rotor assembly use the lock mechanism at all times To use remove plastic bearing cover under the chipper...

Страница 18: ...e crossover relief valve is factory set at 1750 PSI Follow this start up procedure when starting a new installation or when restarting an installation in which the hydrostatic pump has been removed fr...

Страница 19: ...harge pump must be filled before start up Loosen the fitting at the pump on the inlet line until oil bleeds out 4 Start the engine and run at the lowest possible RPM 5 Loosen the motor fittings until...

Страница 20: ...redder more evenly Green material will not discharge Alternately feed dry material or allow material to dry Plugged rotor Clear rotor Loose or worn belts Adjust belt tension or replace belts if needed...

Страница 21: ...air splined coupling etc Pump low on fluid Refill reservoir Purge air from transmission Loose belt between engine and pump Tension drive belt replace if necessary Pump low on fluid Refill reservoir Pu...

Страница 22: ...eel 4 Reversible Tool Steel Rotor Speed 1500 RPM 1500 RPM 1500 RPM Rotor Size 30 Dia X 1 25 30 Dia x 1 25 30 Dia X 1 25 Rotor Weight 275 lbs 275 lbs 275 lbs Rotor Shaft Diameter 1 75 1 75 1 75 Dischar...

Страница 23: ...are with the same strength bolt Torque figures indicated above are valid for non greased or non oiled threads and heads unless otherwise specified Therefore do not grease or oil bolts or capscrews unl...

Страница 24: ...he United States of America by Crary Company Crary Company A Division of TerraMarc Industries 237 12th St NW P O Box 849 West Fargo ND 58078 0849 701 282 5520 FAX 701 282 9522 www bearcatproducts com...

Страница 25: ...tters Kawasaki Strimmers Lawn Mowers Scarifiers Lawn Tractors Leaf Blowers Leaf Vacuums Petrol Chainsaws Petrol Hedge Cutters Ride on lawn mowers Ride on mowers Rotary Mowers Rotavators Ryobi Strimmer...

Отзывы: