Crane Weinman ULL - 7181 Скачать руководство пользователя страница 7

7

Item No.

Name Of Part

1
2
9

14

*26

32
40
53
57
59
71

*73
*89

208
212
215
216
217
218
219
220
221
223
224
226

*227

228
229
230
231

*233

240
245
264

*270

271

*283

Casing
Impeller
Suction Cover
Shaft Sleeve
Impeller Screw
Impeller Key
De

fl

 ector

Base
Suction Elbow
Handhole Cover
Adapter - Seal Head
Gasket
Shaft Seal
Pipe Plug
Cap Screw
Cap Screw
Pipe Plug
O-ring
Cap Screw
Cap Screw
O-ring
Cap Screw
Handhole Cover
Cap Screw
Cap Screw
Gasket
Motor
Washer
Seal Retainer
Pipe Plug
Gasket
Pipe Plug
Machine Screw
Pipe Plug
Impeller Washer
Pipe Nipple
Gasket (Set)

(*) Recommended Spare Parts

Figure ULL

Figure ULL-VM 

Содержание Weinman ULL - 7181

Страница 1: ...ems Inc constant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 119981 Rev E Series ULL and ULL VM Section 1420 Man...

Страница 2: ... discharge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slid...

Страница 3: ...er to Lubrication for proper lubrication of the shaft seal and motor bearings Pumps may be installed on any sufficiently solid support since pump and motor are rigidly aligned The Fig 7171 7172 series pumps may be mounted in a vertical position with the motor above the pump liquid end if vertical mounting is preferred PIPING Suction and discharge piping should be direct with as few fittings as pos...

Страница 4: ...p To completely dismantle the pump follow to order listed below or select sections applicable to make required repairs All gaskets and o rings should be replaced with new parts at reassembly DISASSEMBLY A To inspect or replace impeller and suction cover impeller or suction cover rings if furnished Remove drain plugs and any external piping Fig ULL 1 Remove capscrews 215 and suction cover 9 2 Remov...

Страница 5: ...g certain that end of sleeve is seated against shoulder of motor shaft Note This operation must be done rapidly without allowing the shaft sleeve to cool Do Not allow the sleeve to stop before it is properly seated 6 Hold shaft sleeve snug against the shaft shoulder until shrink begins Allow the sleeve to cool below 100ºF before proceeding with pump assembly 7 Replace deflector 40 on the motor sha...

Страница 6: ... or foot valve to see that it is not plugged or buried in mud or sediment When installing in pond or lake support the suction line so that it will be submerged in water but nut imbedded in mud or sediment A strainer with greater screen area may be required d Add sufficient pipe to keep the submerged end well below the water surface e If caused by suction pipe friction increase the size of the pipe...

Страница 7: ...Impeller Screw Impeller Key Deflector Base Suction Elbow Handhole Cover Adapter Seal Head Gasket Shaft Seal Pipe Plug Cap Screw Cap Screw Pipe Plug O ring Cap Screw Cap Screw O ring Cap Screw Handhole Cover Cap Screw Cap Screw Gasket Motor Washer Seal Retainer Pipe Plug Gasket Pipe Plug Machine Screw Pipe Plug Impeller Washer Pipe Nipple Gasket Set Recommended Spare Parts Figure ULL Figure ULL VM ...

Страница 8: ...formance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATI...

Страница 9: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Страница 10: ...__ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ___________________ Do protection devices comply with pump and motor Amp rating YES___ NO___ Are all electrical and panel entry connections tight YES___ NO___ Is the interior of the panel dry YES___ NO___ Liquid le...

Страница 11: ...s installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO___ Additional Comments ____________________________________________________________________________ ____________________________________________________________________________ ___________________________...

Страница 12: ...Notes ...

Отзывы: