background image

10

FIGURE 3

Содержание Prosser Hymergible 3HPV

Страница 1: ...ult of Crane Pumps Systems Inc constant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 101188 Rev F Model 3HPV Manu...

Страница 2: ...D VIEW Fig 3 10 PARTS LIST 11 RETURNED GOODS POLICY 11 WARRANTY 13 START UP REPORT 14 WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT DIELECTRIC TESTER Other brand and product names are trademarks or registered trademarks of their respective holders HYMERGIBLE is a registered trademark of Crane Pumps Systems Inc PROSSER is a registered trademark of Crane Pumps Systems Inc 1997 1998 2002 2 06 9 0...

Страница 3: ...ways wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as t...

Страница 4: ...RTANT 1 PUMP MAY BE OPERATED DRY FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND OR SEALS 2 THIS PUMP IS APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS LOCATIONS 3 THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS 4 INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE...

Страница 5: ...minutes running dry not pumping water without damage DO NOT allow pump to be buried in mud or sand IMPORTANT Pump should have strainer affixed at all times Inspect and clean the pump strainer periodically for maximum efficiency and performance C 2 Discharge Discharge hose is recommended If rigid pipe is used install so that there is no weight or strain on the pump Install a short pipe nipple into ...

Страница 6: ...ler to gradually slow to a stop Blocking this flow will cause damage to the hydraulic motor and pump seal 1 4 way open center directional valve must be operated in forward direction only or use check valve 4 to prevent reversing 2 Valve quick disconnect coupling 3 Hydraulic motor driving submersible pump 4 Check valve Recommended 5 Flow control Recommended if hydraulic flow is greater than flow re...

Страница 7: ... 2 1 Oil Reservoir 2 Suction strainer 3 Fixed displacement hydraulic pump 4 Diesel or gas engine 5 Pressure gauge 6 Pilot controlled system relief valve 7 Vent valve On Off 8 Valved quick disconnect coupling 9 Fixed displacement hydraulic motor 10 Return filter with by pass valve 11 Hydraulic oil cooler ...

Страница 8: ...ance may be required if a Pump discharge volume is inadequate b Oil leakage from pump is present SECTION F SERVICE AND REPAIR NOTE All item numbers in refer to Figure 3 WARNING Hydraulic power to the pump must be disconnected to prevent personnel danger before any service work is done to the pump CAUTION Always wear eye protection when working on pumps F 1 Disassembly Remove cap screws 12 from top...

Страница 9: ...rform maintenance recommendations If operating problems persist the following chart may be of assistance in identifying and correcting them MATCH CAUSE NUMBER WITH CORRELATING CORRECTION NUMBER NOTE Not all problems and corrections will apply to each pump model PROBLEM CAUSE CORRECTION Pump delivers insufficient capacity 1 Supply pressure flow too low 2 Excessive inflow or pump not properly sized ...

Страница 10: ...10 FIGURE 3 ...

Страница 11: ...rew Socket Hd 6 1 Cone Washer 7 1 Impeller 9 1 Shaft Seal Assembly 10 1 O Ring Top Cover 11 1 Top Cover 12 6 Hex Hd Cap Screw 3 8 6 Lockwasher 13 1 O Ring Motor 14 1 Pipe Plug 15 2 Hex Hd Cap Screw 2 Lockwasher 16 1 Handle 17 1 Hydraulic Coupling Male H T M A 18 1 Hydraulic Coupling Female H T M A 19 1 Nipple 20 1 Elbow 21 2 Hex Hd Cap Screw 2 Lockwasher 22 1 Hydraulic Motor 23 1 Elbow 24 1 Nipple...

Страница 12: ...rformance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUAT...

Страница 13: ...ent To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pump...

Страница 14: ...14 Notes ...

Отзывы: