background image

  

EXTERNAL COMMUNICATION INTERFACE FEATURES: 

 
MDB INTERFACE 

 

Country Code = 1784h 

 

Decimal Place = 2 

 

Scaling Factor = 100 

 

Bill Types Credit : 
 

Currency 

Note 

Note Value (AED) 

USD 

$1 

  3 AED 

USD 

$5 

15 AED 

USD 

$10 

30 AED 

USD 

$20 

60 AED 

GBP 

£5 

25 AED 

GBP 

£10 

51 AED 

EUR 

€5 

21 AED 

EUR 

€10 

43 AED 

EUR 

€20 

86 AED 

 
DIP SWITCHES SETTING*: 

 

SW. #1 

ON state 

OFF state 

Default 

Setting 

SW1.1 

5 USD Disable 

5 USD Enable 

OFF 

SW1.2 

10 USD Disable 

10 USD Enable 

OFF 

SW1.3 

20 USD Disable 

20 USD Enable 

OFF 

SW1.4 

5 GBP Disable 

5 GBP Enable 

OFF 

SW1.5 

10 GBP Disable 

10 GBP Enable 

OFF 

SW1.6 

5 EUR Disable 

5 EUR Enable 

OFF 

SW1.7 

10 EUR Disable 

10 EUR Enable 

OFF 

SW1.8 

20 EUR Disable 

20 EUR Enable 

OFF 

SW. #2 

ON state 

OFF state 

 

SW2.1 

High Security 

High Acceptance 

OFF 

SW2.2 

Override rules disabled 

Override rules enabled 

OFF 

SW2.3 

Reserved 

Reserved 

OFF 

SW2.4 

Service Mode 

To work with a “Host 

Machine Controller” 

OFF 

 

 

 

 

*1 USA and 5, 10, 20 AED are always enable. 
 
 
 
 
 
 

RECYCLING CASSETTE CONTROLS: 
The Recycling Cassette controls are shown on the drawing below. 

RECYCLING CASSETTE DIP SWITCHES SETTING: 

 

Switch 

ON state 

OFF state 

Default Setting 

SW1 

Assign for 10 AED 

Assign for 5 AED 

OFF 

SW2 

Cassette setup mode 

Normal operation 

OFF 

 
RECYCLING CASSETTE INDICATOR: 
After power on Recycling cassette indicator shows control firmware version: 

F1 -> 21 

After initialization indicator shows number of bills inside of the recycling cassette.   
In case of an error it will start flashing showing consequently number of bills and one 
of the following error codes: 

E0h    

– there was a hardware error detected 

E1h    – 

no communication with Coin Changer. In this case device will emulate Coin 

Changer with 1 tube (5 AED or 10 AED). 

 
FEED/UNLOAD BUTTONS: 

The Feed button is used for setting a Loading mode. This mode makes the 

entered bills of a selected denomination to be loaded into the recycling cassette. To 
cancel a loading mode, the Feed button must be pressed again. If bills do not enter 
within 20 seconds, the loading mode will be canceled automatically. 
By pressing the unload button one bill will be dispensed from the recycling cassette 
through the entry channel. If the feed and unload buttons are pressed simultaneously 
then all bills will be unloaded from the recycling cassette into the drop cassette.  

 

RECYCLING CASSETTE SETUP MODE: 
Recycling Cassette setup mode allows user to adjust recycling cassette feed and unload 
levels (maximal number of bills accepted into the cassette and number of bills to be left 
in the cassette during unload operation correspondingly) without need of special 
equipment. In order to enter the setup mode set SW2 to ON. The cassette indicator will 
start blinking “FL”(Fill level) or “UL”(unload level) and the set level consequently.   
  

DIP Switches

Unload button

Feed button

LCD display

Отзывы: