EXTERNAL COMMUNICATION INTERFACE FEATURES:
MDB INTERFACE
•
Country Code = 1784h
•
Decimal Place = 2
•
Scaling Factor = 100
•
Bill Types Credit :
Currency
Note
Note Value (AED)
USD
$1
3 AED
USD
$5
15 AED
USD
$10
30 AED
USD
$20
60 AED
GBP
£5
25 AED
GBP
£10
51 AED
EUR
€5
21 AED
EUR
€10
43 AED
EUR
€20
86 AED
DIP SWITCHES SETTING*:
SW. #1
ON state
OFF state
Default
Setting
SW1.1
5 USD Disable
5 USD Enable
OFF
SW1.2
10 USD Disable
10 USD Enable
OFF
SW1.3
20 USD Disable
20 USD Enable
OFF
SW1.4
5 GBP Disable
5 GBP Enable
OFF
SW1.5
10 GBP Disable
10 GBP Enable
OFF
SW1.6
5 EUR Disable
5 EUR Enable
OFF
SW1.7
10 EUR Disable
10 EUR Enable
OFF
SW1.8
20 EUR Disable
20 EUR Enable
OFF
SW. #2
ON state
OFF state
SW2.1
High Security
High Acceptance
OFF
SW2.2
Override rules disabled
Override rules enabled
OFF
SW2.3
Reserved
Reserved
OFF
SW2.4
Service Mode
To work with a “Host
Machine Controller”
OFF
*1 USA and 5, 10, 20 AED are always enable.
RECYCLING CASSETTE CONTROLS:
The Recycling Cassette controls are shown on the drawing below.
RECYCLING CASSETTE DIP SWITCHES SETTING:
Switch
ON state
OFF state
Default Setting
SW1
Assign for 10 AED
Assign for 5 AED
OFF
SW2
Cassette setup mode
Normal operation
OFF
RECYCLING CASSETTE INDICATOR:
After power on Recycling cassette indicator shows control firmware version:
F1 -> 21
After initialization indicator shows number of bills inside of the recycling cassette.
In case of an error it will start flashing showing consequently number of bills and one
of the following error codes:
E0h
– there was a hardware error detected
E1h –
no communication with Coin Changer. In this case device will emulate Coin
Changer with 1 tube (5 AED or 10 AED).
FEED/UNLOAD BUTTONS:
The Feed button is used for setting a Loading mode. This mode makes the
entered bills of a selected denomination to be loaded into the recycling cassette. To
cancel a loading mode, the Feed button must be pressed again. If bills do not enter
within 20 seconds, the loading mode will be canceled automatically.
By pressing the unload button one bill will be dispensed from the recycling cassette
through the entry channel. If the feed and unload buttons are pressed simultaneously
then all bills will be unloaded from the recycling cassette into the drop cassette.
RECYCLING CASSETTE SETUP MODE:
Recycling Cassette setup mode allows user to adjust recycling cassette feed and unload
levels (maximal number of bills accepted into the cassette and number of bills to be left
in the cassette during unload operation correspondingly) without need of special
equipment. In order to enter the setup mode set SW2 to ON. The cassette indicator will
start blinking “FL”(Fill level) or “UL”(unload level) and the set level consequently.
DIP Switches
Unload button
Feed button
LCD display