background image

 

GENERAL SAFETY INSTRUCTIONS 

 

WARNING!

  

Read and understand all instructions.  Failure to follow all instructions 

listed below may result in electric shock, fire or serious personal injury.  The warnings, 

cautions, and instructions discussed in this instruction manual cannot cover all possible 

conditions and situations that may occur.  It must be understood by the user that 

common sense and caution are a factor which cannot be built into this product, but must 

be supplied by the user. 

 

Do not let your child play with this appliance.  

Serious injury and 

electrocution might be possible.  This humidifier has to be operated by an adult only. 

Children should be supervised to ensure that they do not play with the humidifier. 

 

SAVE ALL INSTRUCTIONS!

 

 

CAUTION:

 A short Power Supply Cord is provided to reduce the risk of personal 

injury resulting from becoming entangled in or tripping over a longer cord.  Extension 

cords are available from local hardware stores and may be used if care is exercised in 

their use.  If an extension cord is required, special care and caution is necessary.  Also 

the extension cord must be (1) marked with an electrical rating of 125 V and at least 13 

A., 1625 W., and (2) the cord must be arranged so that it will not drape over the 

countertop or tabletop where it can be pulled on by children or accidently tripped over. 

 

ELECTRIC POWER 

If the electric circuit is overloaded by other appliances, your humidifier and/or 

appliances may not operate properly. The humidifier should be operated on a separate 

electrical circuit from other operating appliances.  

 

POLARIZED PLUG 

This humidifier has a polarized plug (one blade is wider than the 

other).  As a safety feature to reduce the risk of electrical shock, this 

plug is intended to fit in a polarized outlet only one way.  If the plug 

does not fit fully in the outlet, reverse the plug.  If it still does not fit, 

contact a qualified electrician.  Do not attempt to defeat this safety 

feature. 

 

SAFETY WARNING 

Although your humidifier is easy to operate, for your safety, the below warnings must be 

followed: 

1.

 

Do not place the humidifier near a heat source. 

2.

 

Never leave the humidifier unattended while connected to the electrical outlet. 

3.

 

To avoid any accidents, never cover the Mist Lid when the humidifier is in operation.  

4.

 

Use the humidifier on a smooth, flat, lint-free, non-metallic, waterproof, and level 

surface away from water. 

5.

 

Do not unplug from the wall socket by pulling on the supply cord. 

6.

 

The humidifier must be unplugged: 

A.

 

Before either filling or emptying the Water Base and/or Water Tank. 

B.

 

Before any cleaning or maintenance is performed. 

C.

 

After each use. 

D.

 

If it appears to be faulty. 

 

THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY. 

 

 

 

Содержание EE-6902

Страница 1: ...DIGITAL ULTRASONIC COOL WARM MIST HUMIDIFIER ITEM EE 6902 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFCTIVE USE OF THIS APPLIANCE ...

Страница 2: ...Parts Technical Specifications P 4 Humidifier Features P 5 Operation and Use P 5 Digital Control Panel Instructions P 6 Assembly P 7 Maintenance P 8 Trouble Shooting P 9 Customer Care P 10 Warranty P 11 For information about all CRANE Humidifiers please visit http www crane usa com ...

Страница 3: ...to avoid electric shock 7 Never operate the unit with a damaged cord or plug 8 Always place the unit on a smooth flat lint free non metallic waterproof and level surface and position unit away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move the unit 9 Do not add medicat...

Страница 4: ...tertop or tabletop where it can be pulled on by children or accidently tripped over ELECTRIC POWER If the electric circuit is overloaded by other appliances your humidifier and or appliances may not operate properly The humidifier should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This humidifier has a polarized plug one blade is wider than the other...

Страница 5: ...ist 110W Water Tank Capacity 1 3 Gallon Run Time Per Tank Up to 24 hours Humidifying Capacity Up to 500 sq ft 46 m2 1 Adjustable Mist Output Slot 2 Mist Lid 3 Digital Control Panel 4 Water Tank Handle 5 Water Tank 6 Water Tank Cap 7 Water Base 8 Fan Vent 9 Nebulizer 10 Water Level Sensor Float 7 4 1 2 5 6 8 9 10 3 ...

Страница 6: ...ncy much like the element in a high frequency stereo speaker to create mist An ultrasonic humidifier is whisper quiet and produces a fine mist into the room REMOTE CONTROL This Digital Humidifier includes a Remote Control that can be used to operate your device Simply pull the small plastic tab before use to activate OPERATION AND USE BEFORE EACH USE CHECK HUMIDIFIER PLACEMENT Place the Humidifier...

Страница 7: ...N MIST CONTROL Press this button to change the mist output to Low Medium or High SET HUMIDITY LEVEL Press this button to set desired humidity level You can set the humidity level between 40 80 The recommended humidity level is between 40 60 COOL WARM MIST SELECTOR When humidifier is on cool mist will automatically start To select warm mist press this button and the warm mist setting will activate ...

Страница 8: ...by using the Control Knob 5 Use the Digital Control Panel to select the mode of your choice The blue Power Indicator Light will illuminate In a few seconds mist will start emitting 6 Use the Digital Control Panel to adjust the intensity of the mist output SET THE CORRECT HUMIDITY OUTPUT Adjust the Digital Control Panel so that the mist rises up to be absorbed by the room air Do not set the mist ou...

Страница 9: ...et and empty water from tank base daily 2 Allow tank base to air dry 3 Leave cap off the tank until ready for next use WEEKLY MAINTENANCE 1 Turn off unplug from outlet and empty water from tank base 2 Fill the water tank halfway with warm water Add 2 Tablespoons of white vinegar Shake vigorously and let sit for 30 min Empty tank rinse with plain water TIP Use crushed ice or wire brush to help scru...

Страница 10: ...in a cool place The digital display is on but there is no mist Unplug and re plug into power source Check that there is water in the tank Check for possible mineral deposits on the nebulizer Make sure that nothing blocks the mist output slot Check that the fan vent on bottom of humidifier is not blocked Empty the humidifier and rinse the water base with cool tap water and allow to dry for 30 minut...

Страница 11: ...ne usa com Website www crane usa com NOTE Spare Parts can also be purchased online at www crane usa com ENVIRONMENTAL PROTECTION If the humidifier should no longer operate please be sure to dispose of the unit in an environmentally friendly way by taking it into a public collection point Please do not place broken humidifiers with your regular household waste In the event of a malfunction please s...

Страница 12: ...pplies only to the original purchaser and does not extend to subsequent owners of the product Liability under this warranty is limited to repair or replacement In no event shall liability exceed the purchase price paid by the purchaser of the product Under no circumstances shall there be liability for any loss direct indirect or incidental or consequential damage arising out of or in connection wi...

Отзывы: