INHALER KIT* ASSEMBLY & USE 

(Optional Part Available. Sold Separately)

 

 

1.

 

Make sure Mist Chamber is removed from the base and fill the base with cool water only 
to just below the max indicator.

 

DO NOT

 fill water all the way to the rim. 

DO NOT

 add any medication, essential oils, or salt to the water. 

DO NOT

 use the inhaler without the vent assembly in place.  Steam may cause burns. 

2.

 

Place the Vent Assembly securely onto the base.  The power will not turn on if the Vent 
Assembly is not properly placed on the base.

 

3.

 

Attach the Inhaler Mask by lining up the triangular notch on the mask with the triangular 
notch on the front of the vent assembly.  

DO NOT USE WITHOUT INHALER MASK ATTACHED.

 

4.

 

Plug the power cord into a wall socket and press the power button.  The power light will 
illuminate the mist icon in green when powered on.  

Note:

  It will take 3-5 minutes for the 

water to heat & mist to begin to rise.  

5.

 

Always begin with the vent levers at minimum (all the way to the left).  Rest your face 
gently on the mask.  

Do not press hard

 as the soft plastic may bend allowing steam to 

escape or the inhaler to tip & spill boiling water. 

 

ADJUST THE MIST INTENSITY:

 

by sliding the Vent Lever clockwise to allow more steam/increase 

the temperature or counterclockwise for lower steam flow/lower temperature.  If the steam is 
still uncomfortably warm, lift your face 1-2 inches above the mask.  Breathe normally through 
your nose and mouth, inhaling steam into your nasal and throat passages.

 

 

6.

 

When desired vapor treatment is complete, press the power button to turn off.

 

Note:

 After 20 minutes the unit will automatically shut off to indicaate the end of a full 

treatment cycle.  For another 20 minute treatment cycle, press the power button to start 
again.  When finished with use, disconnect the plug from the outlet and allow time to 
cool before moving or refilling.

 

7.

 

When the base runs out of water, the  power light will illuminate red and mist output will 
stop as a safety feature.  Turn the power off, unplug and allow time to cool before 
refilling the base.  Make sure to use two hands to remove the vent assembly. Do not 
remove vent assembly by lifting from the inhaler mask 

 

NOTE:

  The vent assembly has 2 slots one on each side which can be used with compatible 

Crane Vapor Pads (HS-1950).  

 

*KIT-5202H available at www.crane-usa.com 

 

IHALER KIT MAINTENANCE 

 

AFTER EACH USE 

1.

 

Remove Inhaler Mask and Vent Assembly by lifting vent assembly with two hands.  
Wipe both parts dry with a clean cloth.

 

2.

 

If any water is left in the base, empty and wipe base dry with a clean cloth.

 

NEVER IMMERSE BASE IN WATER. 

 

WEEKLY MAINTENANCE 

If your Inhaler is used 10 or more times a week (or mineral scale builds up in the base) 
follow the weekly maintenance for the humidifier base on 

page 9

1.

 

Wash the Inhaler Mask with mild soap and warm water.  Carefully rinse with fresh, 
clean water to remove soap and dry with a clean cloth. 

2.

 

Wipe the Vent assembly dry with a clean cloth.   

 

WHEN STORING HUMIDIFIER OR INHALER, LET ALL PARTS DRY COMPLETELY BEFORE 
STORING AWAY IN A COOL, DRY PLACE UNTIL NEXT USE. 

Содержание EE-5202H

Страница 1: ...AVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS HUMIDIFIER If you have any questions about the operation of your warm mist humidifier or inhaler please contact Crane Customer Care Toll Free 1 888 599 0992 Email customer service crane usa com ...

Страница 2: ...2 SAVE YOUR DATED PROOF OF PURCHASE You will need this in case of warranty ...

Страница 3: ...ITY Crane USA is dedicated to your environment both inside and outside your home We know if cleaned and maintained properly our products last for years helping to reduce unnecessary use of resources and emissions making new products The Crane manual you are holding is from recycled materials with no added finishes or harmful dyes If the humidifier should no longer operate please be sure to dispose...

Страница 4: ... or plug 12 Always place the unit on a smooth flat lint free non metallic waterproof and level surface and position unit away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move the unit 13 DO NOT add essential oils vapor pads or medication of any type into the Water Basin ...

Страница 5: ...hat it will not drape over the countertop or tabletop where it can be pulled on by children or accidently tripped over ELECTRIC POWER If the electric circuit is overloaded by other appliances your humidifier and or appliances may not operate properly The humidifier should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This humidifier has a polarized plu...

Страница 6: ...ter Tank Cap 9 Medicine Cup 10 Vapor Pad Slot 11 Includes 1 Vapor Pad HS 1950 Fig 3 Inhaler Kit Optional Part Sold Separately 12 Vent Assembly 13 Vent Lever 14 Inhaler Mask 15 Vapor Pad Slots KIT 5202H available at www crane usa com The steam inhaler kit provides a steady flow of warm steam directly to the nose and throat for quick relief of nasal sinus and chest congestion 1 2 3 4 5 6 7 8 9 11 12...

Страница 7: ...r DO NOT PLACE ON CARPET OR TOWEL The fan vent is located on the bottom of the humidifier base The fan vent MUST NOT be obstructed DO NOT PLACE ON WOOD SURFACE or near furniture that can be damaged by too much moisture CAUTION DO NOT attempt to operate the humidifier without water in the Water Tank DO NOT plug or unplug the Power Cord with wet hands as electric shock could occur CHECK WATER LEVEL ...

Страница 8: ...ce and the water tank is not properly placed on the base 3 Plug the power cord into a wall socket and press the power button The power light will illuminate one green water droplet for low Press the power button again to change the mist output to high the light will illuminate 2 green water droplets Press the power button a third time to power off the humidifier Note It will take 3 5 minutes for t...

Страница 9: ...ch may inhibit the output efficiency as well as void the warranty If water remains in the Water Tank for more than a day or two bacterial growth is possible DAILY MAINTENANCE 1 Turn off unplug from outlet and empty water from tank base daily 2 Allow tank base to air dry 3 Leave cap off the tank until ready for next use WEEKLY MAINTENANCE 1 Turn off unplug from outlet and empty water from tank base...

Страница 10: ...ing steam into your nasal and throat passages 6 When desired vapor treatment is complete press the power button to turn off Note After 20 minutes the unit will automatically shut off to indicaate the end of a full treatment cycle For another 20 minute treatment cycle press the power button to start again When finished with use disconnect the plug from the outlet and allow time to cool before movin...

Страница 11: ...f you are pregnant breastfeeding or have asthma consult a doctor before use DO NOT USE if you suffer from epilepsy pads may irritate skin and eyes In case of irritation on skin or contact with eyes rinse with plenty of water and seek medical advice If accidentally ingested seek medical advice immediately In case of any discomfort stop usage and seek medical advice DO NOT place in microwave DO NOT ...

Страница 12: ...t stays red Remove the water level sensor cap with a flathead screwdriver and wash both cap and water level float with warm soapy water Wipe the peg and around the base of the peg with a wet cloth Replace the float then cap and tighten the screw to secure If light does not turn green call Crane Customer Care If there is a strange odor Clean the Water Tank with the water and vinegar solution and ri...

Страница 13: ... This warranty does not apply to normal wear and tear or commercial use In no event shall liability exceed the purchase price paid by the purchaser of the product Under no circumstances shall there be liability for any loss direct indirect or incidental or consequential damage arising out of or in connection with the use of this product This warranty is valid only in the 48 contiguous states plus ...

Страница 14: ...14 ...

Отзывы: