REPLACING THE FILTER 

 

When the Filter Reset indicator is flashing, it is an indication to replace the filter. Once 
you have replaced the filter, press the Filter Reset icon down for 3 seconds to reset 
the system. The filter indicator light will turn off when it has Reset. On average, the 
Filter needs to be replaced 6 months. Filter life will depend on air quality and usage. 

 

1.

 

ALWAYS turn off and unplug the air purifier from power outlet before 
replacing the filter. 

 

2.

 

Remove the back cover by pressing the groove of the back cover with finger, 
then pull out the back cover slightly and lift the cover off the back of the unit. 

 

3.

 

Use the PULL TAB on the filter to remove the filter from the unit. Discard the old 
filter. DO NOT attempt to wash the filter. Insert the new filter into the unit. 

 

4.

 

Once you have replaced the filter, align the back cover and the fixed grooves, 
insert the cover into the grooves on the bottom. Gently push the top of the 
cover into place to secure it to the back on the unit. Press the FILTER RESET 
button down for 3 seconds to reset the system. 

 

NOTE: 

Replacement HEPA Filter

 #HS- 1951 

can be purchased online at 

 

www.crane-philippines.com 

 

 

REPLACING THE UV BULB 

 

WARNING 

 

Always make sure that the air purifier is turned OFF and UNPLUGGED from power 
outlet before replacing UV bulb. Always use caution when handling the UV bulb to 

prevent accidental breaking of the bulb. NEVER touch the glass part of the bulb. 

 

Oil from fingers will reduce the performance of the UV bulb. Always use gloves or 
handle the bulb only by the metal area on the bulb. Failure to do so may risk shock, 

fire hazard or damage the unit and replacement lamp. 

 

Carefully turn the UV bulb towards the air purifier unit to open the release for the UV 
bulb. Lift the UV bulb out of the air purifier unit. Insert a new UV bulb into the openings 

and gently turn the UV bulb to lock into the air purifier unit. 

 
 

DO NOT 

use a vacuum to pick up broken bulb glass or handle broken bulb with your

 

hands. Sweep debris into a plastic bag and dispose properly. Contact your local waste 

management authority for instruction regarding recycling and the proper disposal of 
the old bulb(s). 

 
 

The UV bulb is designed to provide approximately one year continuous operation. After one 
year the UV bulb

’s effectiveness is greatly 

reduced. For maximum protection, replace after a 

year or if the blue UV bulb does not illuminate when the UV switch is ON. 

 
 
 
 
 
 

 

Содержание EE-5072

Страница 1: ...about the operation of your purifier please contact Crane Customer Care Email customercare keywestinternationale com ph Email Sales crane philippines com Website www crane philippines com PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PURIFIER ...

Страница 2: ...SAVE YOUR DATED PROOF OF PURCHASE You will need this in case of warranty PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PURIFIER ...

Страница 3: ...ated to your environment both inside and outside your home We know if cleaned and maintained properly our products last for years helping to reduce unnecessary use of resources and emissions making new products The Crane manual you are holding is from recycled materials with no added finishes or harmful dyes If the purifier should no longer operate please be sure to dispose of it in an environment...

Страница 4: ...air purifier is not in use before cleaning inserting or removing parts or before moving to another location 9 NEVER run air purifier until it is fully assembled 10 NEVER drop or insert bars metal objects or any objects into any openings 11 Use appliance only for the intended household use as described in this manual Do not use outdoors 12 Never use the power cord to pick up carry drag pull or lift...

Страница 5: ...s and situations that may occur It must be understood by the user that common sense and caution are a factor which cannot be built into this product but must be supplied by the user THIS AIR PURIFIER IS NOT A TOY Do not let your child play with this product Serious injury and electrocution might be possible This air purifier has to be operated by an adult only Children should be supervised to ensu...

Страница 6: ... to the electrical outlet 3 To avoid any accidents never cover the air grill when the purifier is in operation 4 Use the purifier on a stable surface away from water 5 Do not unplug from the wall socket by pulling on the supply cord 6 The purifier must be unplugged A Before any cleaning or maintenance is performed B After each use C If it appears to be faulty THIS PRODUCT IS INTENDED FOR HOUSEHOLD...

Страница 7: ...tlet 3 Air Quality Indicator 3 Fig 2 Back 4 Back Cover 5 Smart Sensor 5 6 4 6 3 in 1 HEPA Filter 7 UV Light Bulb 7 Fig 3 Control Panel 8 UV Light Indicator Filter Reset 9 Child Lock 10 Timer 11 Sleep 12 Fan Speed AUTO LO MED HI 13 Power ON OFF 13 8 9 10 11 12 5 ...

Страница 8: ...n for the filter Level 2 HEPA Filter HEPA stands for High Efficiency Particulate Air The inlet grill of your air purifier draws in dirty air Crane s air purifier true HEPA filter removes at least 99 97 of all particles as small as 0 3 microns Microns are used to measure the size of these microscopic airborne particles Allergens such as pollen smoke animal dander mold spores and dust get trapped in...

Страница 9: ...ht function will work for a 20 minute cycle and then shut off automatically NOTE The UV Light function will run for a 30 minute cycle every 24 hours when the unit is left on continually It is not recommended to use the UV function more than 30 minutes a day in a non medical place 4 Press the Sleep icon to turn on the sleep more In sleep mode all lights will turn off and the fan will run in the LOW...

Страница 10: ...can be purchased online at www crane philippines com REPLACING THE UV BULB WARNING Always make sure that the air purifier is turned OFF and UNPLUGGED from power outlet before replacing UV bulb Always use caution when handling the UV bulb to prevent accidental breaking of the bulb NEVER touch the glass part of the bulb Oil from fingers will reduce the performance of the UV bulb Always use gloves or...

Страница 11: ... may be cleaned by wiping with a lightly damp cloth DO NOT ALLOW WATER TO GET INTO THE INTAKE AND OUTLET GRILLS DO NOT USE GASOLINE POLISH OR ANY CHEMICAL SOLUTION TO CLEAN AIR PURIFIER 3 The intake grill and outlet grill can be cleaned of dust with a small soft brush 4 If you wish to lightly clean the inside of the air purifier please remove filter and ONLY use a dry soft cloth to lightly wipe do...

Страница 12: ...k of the unit Make sure the air purifier fan speed is on Low Medium or High In the AUTO fan function the fan If the air purifier does will only run when the air quality is poor not operate Make sure the power cord is plugged into a working power outlet If the above solutions do not work please contact Crane Customer Care Make sure that the intake and outlet grills are not blocked and are free of d...

Страница 13: ...the product This warranty does not apply to normal wear and tear or commercial use In no event shall liability exceed the purchase price paid by the purchaser of the product Under no circumstances shall there be liability for any loss direct indirect or incidental or consequential damage arising out of or in connection with the use of this product This warranty is valid all over the Philippines Th...

Страница 14: ...11 ...

Страница 15: ......

Отзывы: