13
CHART ‘H’
MODEL NO
.
SIZE
IMP
. DIA.
INCHES
(MM)
HP
V
O
LT
PH
HZ
RPM
NEMA ST
AR
T
CODE
FULL LO
A
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED RO
T
O
R
AMPS
DRIVER FRAME
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
7366N-663-1K-32N
6DL
8.07 (205)
15
208
3
60
1750
E
51.8
1.2
59.0
206.6
3
125498
8/4 - 18/4
1.12 ±.02
.084 - .337
230
46.9
1.2
54.3
3
125498
8/4 - 18/4
1.12 ±.02
460
23.4
1.2
27.2
103.3
3
125497
12/4 - 18/4
.87 ±.02
7366N-663-75-32N
6DL
8.07 (205)
15
575
3
60
1750
E
18.7
1.2
21.7
82.6
3
125497
12/4 - 18/4
.87 ±.02
.510
7366N-663-1L-32N
6DL
8.47 (215)
20
230
3
60
1750
J
53.7
1.2
59.0
383.9
3
125498
8/4 - 18/4
1.12 ±.02
.084 - .337
460
26.9
1.2
29.9
3
125497
12/4 - 18/4
.87 ±.02
7366N-663-76-32N
6DL
8.47 (215)
20
575
3
60
1750
J
21.5
1.2
23.9
153.5
3
125497
12/4 - 18/4
.87 ±.02
.510
7366N-663-62-32N
6DL
8.66 (220)
25
460
3
60
1750
G
33.2
1.2
38.9
191.9
3
125499
8/4 - 18/4
1.12 ±.02
.337
7366N-663-77-32N
6DL
8.66 (220)
25
575
3
60
1750
G
26.6
1.2
31.1
153.5
3
125497
12/4 - 18/4
.87 ±.02
.510
7366N-663-63-32N
6DL
8.86 (225)
30
460
3
60
1750
F
38.9
1.2
45.9
191.9
3
125499
8/4 - 18/4
1.12 ±.02
.337
7366N-663-78-32N
6DL
8.86 (225)
30
575
3
60
1750
F
31.1
1.2
36.7
153.5
3
125499
8/4 - 18/4
1.12 ±.02
.510
7366N-664-1H-32N
6DL
8.66 (220)
7.5
208
3
60
1150
J
24.9
1.2
29.6
137.6
3
125496
12/4 - 18/4
.87 ±.02
.329
230
24.0
1.2
27.6
3
125496
12/4 - 18/4
.87 ±.02
460
12.0
1.2
13.8
68.8
3
125497
12/4 - 18/4
.87 ±.02
1.315
7366N-664-73-32N
6DL
8.66 (220)
7.5
575
3
60
1150
J
9.6
1.2
11.0
55.0
3
125497
12/4 - 18/4
.87 ±.02
1.960
7366N-664-1J-32N
6DL
8.86 (225)
10
208
3
60
1150
F
32.9
1.2
41.0
137.6
3
125498
8/4 - 18/4
1.12 ±.02
.329
230
30.2
1.2
35.8
3
125498
8/4 - 18/4
1.12 ±.02
460
15.1
1.2
17.9
68.8
3
125497
12/4 - 18/4
.87 ±.02
1.315
7366N-664-74-32N
6DL
8.86 (225)
10
575
3
60
1150
F
12.1
1.2
14.3
55.0
3
125497
12/4 - 18/4
.87 ±.02
1.960
▲
CORD SOLD SEP
ARA
TEL
Y.
IMPOR
TANT !
1.) MOISTURE
AND
TEMPERA
TURE
SENSORS
MUST
BE CONNECTED
T
O
V
ALIDA
TE
THE CSA
LISTING.
2.)
A
SPECIAL
MOISTURE SENSOR RELA
Y
IS REQUIRED IN
THE CONTROL
P
ANEL
FOR PROPER OPERA
TION OF
THE MOISTURE SENSORS.CONT
ACT
CP&S
FOR INFORMA
TION
CONCERNING MOISTURE SENSING RELA
YS FOR CUST
OMER SUPPLIED CONTROL
P
ANELS.
3.)
THESE PUMPS
ARE CSA
LISTED FOR PUMPING W
A
TER
AND W
ASTEW
A
TER.
DO NOT USE T
O
PUMP
FLAMMABLE LIQUIDS
. NOT
SUIT
ABLE FOR ENVIRONMENTS
CONT
AINING GASOLINE OR HEXANE.
4.)
INST
ALLA
TIONS SUCH
AS DECORA
TIVE FOUNT
AINS OR W
A
TER FEA
TURES PROVIDED FOR VISUAL
ENJOYMENT
MUST
BE INST
ALLED IN
ACCORDANCE
WITH
THE
NA
TIONAL
ELECTRIC CODE
ANSI/NFP
A
70
AND/OR
THE
AUTHORITY
HA
VING JURISDICTION.
THIS PUMP
IS NOT
INTENDED FOR USE IN SWIMMING PO
OLS, RECREA
TIONAL
W
A
TER P
ARKS, OR INST
ALLA
TIONS IN WHICH HUMAN CONT
ACT
WITH PUMPED MEDIA
IS
A
COMMON OCCURRENCE.
5.)
WINDING RESIST
ANCE ± 7.5%. WINDING RESIST
ANCE MEASURED IN OHMS @ 25°C (BETWEEN LINES)
A
T
MOT
OR LEADS.
6.)
PUMP
RA
TED FOR OPERA
TION
A
T
± 10% VOL
TAGE
A
T
MOT
OR.
7.)
CORD SUFFIX: XF - 50 FEET
, XJ - 75 FEET
, OR XL
- 100 FEET
. CORD SOLD SEP
ARA
TEL
Y.
Содержание Deming 7366N-410-1H-32N
Страница 23: ...23 FIGURE 9 Cross Section ...
Страница 24: ...24 FIGURE 10 Exploded View ...
Страница 47: ...47 Notes ...
Страница 48: ...48 Notes ...