Engineering the Future of Payment Solutions
2720 Steeles Avenue West, Unit 2-3
Concord, ON Canada L4K 4S3
phone 905 303 8874 fax 905 303 8875
4. Inspection
a. Self Test Functionality:
CashCode’s MSM Bill Validator is equipped with a self-diagnostic feature to aid in repair and
maintenance. When the power to the Bill Validator is restore, the unit begin its self-diagnostic
operation. If the self-diagnostic test is passed, then the status light will turn green. If an error is detected,
then the status light on the front of the Bill Validator will blink red. Please refer to the Diagnostic section of
the manual for a complete list of error codes and corrective actions.
b. Visual Inspection:
Open the guide assembly to access the bill path
Ensure:
No scratches present on the guides and optical sensors
No dirt or cracks present on the surface of the transport rollers and rubber o-rings.
No dirt on the surface of the optical sensors
The entire bill path is clean of paper debris or residue
5. Cassette Maintenance with locking features installed.
It is recommended to check and tighten locks of both the inside and outside security lock every four (4)
months by tightening the screw and nut as showed on below procedure.
Needed Tools
Phillips screwdriver
15mm socket and driver
Optional: Torque screwdriver to accommodate Philips screwdriver bit and 15mm socket (torque 12kg-
cm/11in-lbs for the M3 screw, and 20kg-cm/18in-lbs for the nut)