MODEL NO
HP
VOLT/PH
Hz
RPM
(Nom)
NEMA
START
CODE
INSUL.
CLASS
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
CORD
SIZE
CORD
TYPE
CORD
O.D
inch (mm)
WINDING RESISTANCE
Emerson
Main-Start
Franklin
Main-Start
G.E.
Main-Start
4SE914L
0.9
120/1
60
1750
A
B
11.6
21.3
14/3
SJTOW
0.373 (9.5)
1.51-16.10
4SE924L
0.9
240/1
60
1750
C
B
5.9
14.9
14/3
SOW
0.530 (13.5)
3.38-9.30
5.69-18.74
4SE994L
0.9
200-240/3
60
1750
C/F
B
3.2/3.0
9.8/11.0
14/4
SOW
0.570 (14.5)
10.20
13.00
4SE944L
0.9
480/3
60
1750
E
B
1.5
5.3
14/4
SOW
0.570 (14.5)
40.80
52.00
4SE954L
0.9
600/3
60
1750
C
B
1.0
3.4
14/4
SOW
0.570 (14.5)
77.60
89.76
4SE1474L
1.4
200-240/1
60
1750
A/D
F
7.4/7.0 21.5/25.8
14/3
SOW
0.530 (13.5)
1.86-10.20
2.74-10.56
4SE1494L
1.4
200-240/3
60
1750
B/E
B
4.8/4.5 13.7/15.4
14/4
SOW
0.570 (14.5)
5.49
6.28
4SE1444L
1.4
480/3
60
1750
E
F
2.2
7.7
14/4
SOW
0.570 (14.5)
21.96
24.51
4SE1454L
1.4
600/3
60
1750
F
B
1.5
7.2
14/4
SOW
0.570 (14.5)
34.36
36.60
4SE1974L
1.9
200-240/1
60
1750
A/B
F
8.8/8.3 21.5/25.8
14/3
SOW
0.530 (13.5)
1.86-10.20
2.74-10.56
4SE1994L
1.9
200-240/3
60
1750
A/B
B
5.3/5.1 13.7/15.4
14/4
SOW
0.570 (14.5)
5.49
6.28
4SE1944L
1.9
480/3
60
1750
B
B
2.5
7.7
14/4
SOW
0.570 (14.5)
21.96
24.51
4SE1954L
1.9
600/3
60
1750
C
B
1.9
7.2
14/4
SOW
0.570 (14.5)
34.36
36.60
4SE914DS
0.9
120/1
60
1750
A
B
11.6
21.3
14/3
SJTOW
0.373 (9.5)
1.51-16.10
4SE924DS
0.9
240/1
60
1750
C
B
5.9
14.9
14/3
SOW
0.530 (13.5)
3.38-9.30
5.69-18.74
4SE994DS
0.9
200-240/3
60
1750
C/F
B
3.2/3.0
9.8/11.0
14/4
SOW
0.570 (14.5)
10.20
13.00
4SE944DS
0.9
480/3
60
1750
E
B
1.5
5.3
14/4
SOW
0.570 (14.5)
40.80
52.00
4SE954DS
0.9
600/3
60
1750
C
B
1.0
3.4
14/4
SOW
0.570 (14.5)
77.60
89.76
4SE1474DS
1.4
200-240/1
60
1750
A/D
F
7.4/7.0 21.5/25.8
14/3
SOW
0.530 (13.5)
1.86-10.20
2.74-10.56
4SE1494DS
1.4
200-240/3
60
1750
B/E
F
4.8/4.5 13.7/15.4
14/4
SOW
0.570 (14.5)
5.49
6.28
4SE1444DS
1.4
480/3
60
1750
E
F
2.2
7.7
14/4
SOW
0.570 (14.5)
21.96
24.51
4SE1454DS
1.4
600/3
60
1750
F
F
1.5
7.2
14/4
SOW
0.570 (14.5)
34.36
36.60
4SE1974DS
1.9
200-240/1
60
1750
A/B
F
8.8/8.3 21.5/25.8
14/3
SOW
0.530 (13.5)
1.86-10.20
2.74-10.56
4SE1994DS
1.9
200-240/3
60
1750
A/B
F
5.3/5.1 13.7/15.4
14/4
SOW
0.570 (14.5)
5.49
6.28
4SE1944DS
1.9
480/3
60
1750
B
B
2.5
7.7
14/4
SOW
0.570 (14.5)
21.96
24.51
4SE1954DS
1.9
600/3
60
1750
C
F
1.9
7.2
14/4
SOW
0.570 (14.5)
34.36
35.60
Winding Resistance ± 5%, measured from terminal block. Pump Rated for Operation at ± 10% Voltage at Motor.
OPTIONAL - Temperature sensor cord for 3 phase models is 14/3 SOW, 0.530 (13.5mm) O.D.
OPTIONAL - Moisture sensor cord is 18/5 SOW, 0.470 (12mm) O.D.
OPTIONAL - Moisture & Temperature sensor cord for 3 phase models is 18/5 SOW, 0.470 (12mm) O.D.
If current through the temperature sensor exceeds the values
listed, an intermediate control circuit relay must be used to
reduce the current or the sensor will not work properly.
TEMPERATURE SENSOR ELECTRICAL RATINGS
Volts
Continuous
Amperes
Inrush
Amperes
110-120
3.00
30.0
220-240
1.50
15.0
440-480
0.75
7.5
600
0.60
6.0
C-4.3) Moisture Sensors - DS Models: (Optional)
A normally open (N/O) detector is installed in the pump
seal chamber which will detect any moisture present. It is
recommended that this detector be connected in series to an
alarm device or the motor started coil to alert the operator that
a moisture detect has occurred. In the event of a moisture
detect, check the individual moisture sensor probe leads for
continuity, (∞ resistance = no moisture) and the junction box/
control box for moisture content. The above situations may
induce a false signal in the moisture detecting circuit. If none
of the above tests prove conclusive, the pump(s) should be
pulled and the source of the failure identifi ed and repaired.
IF A MOISTURE DETECT HAS OCCURRED SCHEDULE
MAINTENANCE AS SOON AS POSSIBLE.
C-4.4) Wire Size:
Consult a qualifi ed electrician for proper wire size if additional
power cable length is required. See table for electrical
information.
SECTION: D START-UP OPERATION
D-1) Check Voltage and Phase:
Before operating pump, compare the voltage and phase
information stamped on the pump identifi cation plate to the
available power.
D-2) Check Pump Rotation:
Before putting pump into service for the fi rst time, the motor
rotation must be checked. Improper motor rotation can result
in poor pump performance and can damage the motor and/
or pump. To check the rotation, suspend the pump freely,
momentarily apply power and observe the “kickback”.
“Kickback” should always be in a counter-clockwise direction
as viewed from the top of the pump motor housing.
Содержание BARNES 4SE-DS Series
Страница 15: ...15 FIGURE 15 CONTIUED ...
Страница 17: ...17 FIGURE 16 4SE L Series Single Seal ...
Страница 18: ...18 FIGURE 17 4SE L Series Single Seal ...
Страница 19: ...19 FIGURE 18 4SE DS Series Double Seal ...
Страница 20: ...20 FIGURE 19 4SE DS Series Double Seal ...
Страница 24: ...24 Notes ...