TROUBLE SHOOTING

CAUTION !

 Always disconnect the pump from the electrical power source before handling.

If the system fails to operate properly, carefully read instructions and perform maintenance recommendations.

If operating problems persist, the following chart may be of assistance in identifying and correcting them:

MATCH “CAUSE” NUMBER WITH CORRELATING “CORRECTION” NUMBER

.

NOTE:

 Not all problems and corrections will apply to each pump model.

PROBLEM

CAUSE

CORRECTION

Pump will not run

1.

 Poor electrical connection, blown fuse, 

tripped breaker or other interruption of power, 

improper power supply.

2.

 Motor or switch inoperative (to isolate 

cause, go to manual operation of pump).

2a.

 Float movement restricted.

2b.

 Switch will not activate pump or is defective.

2c.

 Defective motor

3.

 Insufficient liquid level.

1. Check all electrical connections for 

security. Have electrician measure current 

in motor leads, if current is within ±20% 

of locked rotor Amps, impeller is probably 

locked. If current is 0, overload may be 

tripped. Remove power, allow pump to cool, 

then recheck current.

2a. Reposition pump or clean basin as 

required to provide adequate clearance for 

float.

2b. Disconnect level control. Set ohmmeter 

for a low range, such as 100 ohms full scale 

and connect to level control leads. Actuate 

level control manually and check to see that 

ohmmeter shows zero ohms for closed switch 

and full scale for open switch. (Float Switch).

2c. Check winding insulation (Megger Test) 

and winding resistance. If check is outside 

of range, dry and recheck. If still defective, 

replace per service instructions.

3. Make sure liquid level is at least equal to 

suggested turn-on point.

4. Recheck all sizing calculations to 

determine proper pump size.

5. Check discharge line for restrictions, 

including ice if line passes through or into 

cold areas.

6. Remove and examine check valve for 

proper installation and freedom of operation.

7. Open valve.

8. Check impeller for freedom of operation, 

security and condition. Clean impeller and 

inlet of any obstruction.

9. Loosen union slightly to allow trapped air 

to escape.Verify that turn-off level of switch 

is set so that the suction is always flooded. 

Clean vent hole.

10. Check rotation. If power supply is three 

phase, reverse any two of three power supply 

leads to ensure proper impeller rotation..

11. Repair fixtures as required to eliminate 

leakage.

12. Check pump temperature limits & fluid 

temperature.

13. Replace portion of discharge pipe with 

flexible connector.

14. Turn to automatic position.

15. Check for leaks around basin inlet and 

outlets.

16. Inspect motor shaft runout. Inspect 

bearings. Replace as necessary.

Pump will not turn off

2a. Float movement restricted.

2b. Switch will not activate pump or is defective.

4. Excessive inflow or pump not properly sized 

for application.

9. Pump may be airlocked

14. H-O-A switch on panel is in “HAND” position

Pump hums but does not run

1. Incorrect voltage

8. Impeller jammed or loose on shaft, worn or 

damaged, impeller cavity or inlet plugged.

Pump delivers insufficient capacity

1. Incorrect voltage.

4. Excessive inflow or pump not properly sized 

for application.

5. Discharge restricted.

6. Check valve stuck closed or installed backwards.

7. Shut-off valve closed.

8. Impeller jammed or loose on shaft, worn or 

damaged, impeller cavity or inlet plugged.

9. Pump may be airlocked.

10. Pump running backwards

Pump cycles too frequently or runs 

periodically when fixtures are not in use

6. Check valve stuck closed or installed 

backwards.

11. Fixtures are leaking.

15. Ground water entering basin.

Pump shuts off and turns on indepen

-

dent of switch, (trips thermal overload 

protector). 

CAUTION!

  Pump may start 

unexpectedly. Disconnect power supply.

1. Incorrect voltage.

4. Excessive inflow or pump not properly sized 

for application.

8. Impeller jammed, loose on shaft, worn or 

damaged, impeller cavity or inlet plugged.

12. Excessive water temperature. 

(internal protection only)

Pump operates noisily or vibrates 

excessively

5. Debris in impeller cavity or broken impeller

10. Pump running backwards

13. Piping attachments to buiding structure too 

rigid or too loose.

16. Worn bearings, motor shaft bent.

Содержание Barnes 3SE-L Series

Страница 1: ...rane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Brampton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 133410 Rev H Series 3SE L 3HP Vertical Discharge 3450RPM 60Hz 3SE L 3HP Vertical Discharge 1750RPM 60Hz 3SEH L 3HP Horizontal Disc...

Страница 2: ... 3SE L 3450RPM 18 19 CROSS SECTION 3SE L 1750RPM Fig 11a 11b 20 21 EXPLODED VIEW 3SE L 1750RPM Fig 12 22 PARTS LIST 3SE L 1750RPM 23 24 WARRANTY 27 WARRANTY REGISTRATION 28 RETURNED GOODS POLICY 28 SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT see parts list PRESSURE GAUGE KIT see parts list Other brand and product names are trademarks or registered trademark...

Страница 3: ...OT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufact...

Страница 4: ...uirrel Cage Induction Insulation Class B THREE PHASE 200 230 460 60Hz is Tri voltage motor 575V Requires overload protection to be included in control panel OPTIONAL EQUIPMENT Seal Material Impeller Trims Additional Cord SECTION A PUMP SPECIFICATIONS 3450RPM 21 78 553 6 34 161 2 13 54 11 05 281 3 29 84 14 68 373 7 32 186 3 00 N P T DISCHARGE 21 78 553 3 43 84 13 25 336 8 00 203 10 50 267 3 00 125 ...

Страница 5: ...48 Class 30 VOLUTE Cast Iron ASTM Class 30 SEAL PLATE Cast Iron ASTM Class 30 IMPELLER Design 2 Vane Semi open with Pump out vanes on Back side Dynamically balanced ISO G6 3 Material Cast Iron Class 30 SHAFT 416 Stainless Steel SQUARE RINGS Buna N HARDWARE 300 Series Stainless Steel PAINT Air dry enamel top coat SEAL Design Single Mechanical in oil filled reservoir Material Rotating Faces Carbon S...

Страница 6: ... basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage effluent or other nonexplosive or noncorrosive wastewater and shall NOT be installed in locations classified as Class I Division 1 hazardous in accordance with the National Electrical Code NEC ANSI NFPA 70 or The Canadian Electrical Code Never install the pump in a trench ditch or hole with a dirt b...

Страница 7: ...the values listed an intermediate control circuit relay must be used to reduce the current or the sensor will not work properly TEMPERATURE SENSOR ELECTRICAL RATINGS Volts Continuous Amperes Inrush Amperes 220 240 1 50 15 0 440 480 0 75 7 5 575 600 0 60 6 0 C 4 4 Wire Size Consult a qualified electrician for proper wire size if additional power cable length is required See table for electrical inf...

Страница 8: ...7 4 1 40 3SE3044L 3 0 460 3 60 1750 D F 9 0 28 0 14 4 SOOW SOW 57 14 5 6 30 3SE3054L 3 0 575 3 60 1750 E B 5 9 23 0 14 4 SOOW SOW 57 14 5 9 90 HORIZONTAL Series 3SEH3032L 3 0 230 3 60 3450 B F 16 4 40 0 12 4 SOOW SOW 68 17 4 2 30 3SEH3042L 3 0 460 3 60 3450 B F 8 2 20 0 14 4 SOOW SOW 57 14 5 9 10 3SEH3052L 3 0 575 3 60 3450 B F 6 5 16 0 14 4 SOOW SOW 57 14 5 14 10 3SEH3024L 3 0 230 1 60 1750 A F 2...

Страница 9: ...lling with oil To locate the leak perform a pressure test as per section F 1 4 After leak is repaired refill with new oil as per section F 1 3 F 1 3 Replacing Oil Motor Housing Set unit upright and refill with new cooling oil as per Table 1 see parts list for amount Fill to just above motor as an air space must remain in the top of the motor housing 2 to compensate for oil expansion see Figures 2 ...

Страница 10: ... Figure 9 and 10 F 2 2 Reassembly To install impeller 28 apply a thin film of oil to motor shaft and slide impeller straight onto shaft keeping keyways lined up Drive key 33 into keyway Locate washer 35 apply thread locking compound to shaft threads thread hex nut 34 to shaft and torque to 40 ft lbs Rotate impeller to check for binding Position square ring 42 on volute flange and position impeller...

Страница 11: ...tationary members chips and scratches on either seal face DO NOT interchange seal components replace the entire shaft seal 46 If replacing seal remove stationary 46a from seal plate 25 by prying out with flat screwdriver Bearing Examine bearing 47 and replace if required If replacement is required remove bearing 47 from motor shaft using a wheel puller Washer 9 retaining ring 30 and conduit bushin...

Страница 12: ... in paragraph F 1 4 Make wire connections as outlined in paragraph F 3 3 Insert female end of cord plug into housing bore aligning timing mark with hole in terminal block 27 see Figure 5 Compress cord plug with compression flange 10a by tightening cap screws 24 into the motor housing 2 Torque to 132 in lbs SECTION G REPLACEMENT PARTS G 1 ORDERING REPLACEMENT PARTS When ordering replacement parts A...

Страница 13: ...13 FIGURE 10 ...

Страница 14: ...urity and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 ...

Страница 15: ...11 12 48 23 1 47 14 2 25 46 17 28 16 42 9 30 29 21 27 34 35 33 49 18 OPTIONAL SENSOR CABLE ASSEMBLY OIL LEVEL 44 OPTIONAL SENSOR 7 6 4 43 TERMINAL BLOCK FIGURE 11a CROSS SECTION 3SE L 3450RPM VERTICAL DISCHARGE ...

Страница 16: ...1 12 48 23 1 47 14 2 25 46 17 28 16 42 9 30 29 21 27 34 35 33 49 18 OPTIONAL SENSOR CABLE ASSEMBLY OIL LEVEL 44 OPTIONAL SENSOR 7 6 4 43 TERMINAL BLOCK FIGURE 11b CROSS SECTION 3SE L 3450RPM HORIZONTAL DISCHARGE ...

Страница 17: ...17 26A 24 43 42 34 35 44 28 39 49 16 17 46 25 42 47 33 9 14 30 1 29 21 18 23 22 19 20 2 5 45 7 4 6 43 12 48 27 8 10 4 6 43 11 26B FIGURE 12 EXPLODED VIEW 3SE L 3450RPM ...

Страница 18: ...or Housing 14 1 053749 Conduit Bushing 16 1 062641 Pull Washer 17 1 061829 Exclusion Seal Buna N 18 1 016660 Self Tap Screw 19 4 20 14 1 3 8 Lock washer SS 20 4 15 23 1 3 8 16 Hex Nut SS 21 1 105111B Ground Wire 12AWG x 8 00 LG 230V 3 Phase 1 105111 Ground Wire 14AWG x 8 00 LG 460 575V 3 Phase 22 1 625 02117 Fiberglass Sleeve 460 575V 3 Phase 2 625 02117 Fiberglass Sleeve 230V 3 Phase 23 1 See BOM...

Страница 19: ...1 026989 Shim 010 use as required 3 028121 Shim 030 use as required TABLE 2 POWER AND SENSOR CORD SETS MODEL NUMBER 30 FT POWER 50 FT POWER 100 FT POWER TERMINAL BLOCK POWER 3SE3032L 109492XC 109492XF 109492XL 103586 3SE3042L 103742XC 103742XF 103742XL 103583 3SE3052L 103742XC 103742XF 103742XL 103583 3SEH3032L 109492XC 109492XF 109492XL 103586 MODEL NUMBER 30 FT SENSOR 50 FT SENSOR 100 FT SENSOR ...

Страница 20: ...CTION 3SE L 1750RPM VERTICAL DISCHARGE FIGURE 13a 10 OIL LEVEL OPTIONAL SENSOR OPTIONAL SENSOR CABLE ASSEMBLY TERMNAL BLOCK 7 6 8 12 27 4 43 30 47 46 17 16 49 42 33 28 44 35 34 11 6 15 48 3 18 21 1 2 9 14 25 4 43 ...

Страница 21: ...TION 3SE L 1750RPM HORIZONTAL DISCHARGE FIGURE 13b 10 OIL LEVEL OPTIONAL SENSOR OPTIONAL SENSOR CABLE ASSEMBLY TERMNAL BLOCK 7 6 8 12 27 4 43 30 47 46 17 16 49 42 33 28 44 35 34 11 6 15 48 3 18 21 1 2 9 14 25 4 43 ...

Страница 22: ...22 26A 46 24 42 34 35 28 49 39 17 16 25 42 47 9 14 30 33 1 3 15 21 18 19 20 2 5 7 4 6 12 27 48 8 10 11 4 6 43 44 22 45 43 43 26B FIGURE 14 EXPLODED VIEW 3SE L 1750RPM ...

Страница 23: ...029034 Oil Motor Housing 14 1 053749 Conduit Bushing 15 1 133495 Bracket Capacitor 16 1 062641 Pull Washer 17 1 061829 Exclusion Seal 18 1 016660 Self Tap Screw 19 4 20 14 1 3 8 Lock washer SS 20 4 15 23 1 3 8 16 Hex Nut SS 21 1 105111A Ground Wire Green 10AWG x 8 00 LG 230V 1 Phase 1 105111B Ground Wire Green 12AWG x 8 00 LG 230V 3 Phase 1 105111 Ground Wire Green 14AWG x 8 00 LG 460 575V 3 Phase...

Страница 24: ...equired 2 028120 Shims 010 use as required 50 1 027269 Square Ring 7 50 TABLE 3 POWER AND SENSOR CORD SETS MODEL NUMBER 30 FT POWER 50 FT POWER 100 FT POWER TERMINAL BLOCK POWER 3SE3024L 103769XC 103769XF 103769XL 103760 3SE3034L 109492XC 109492XF 109492XL 103586 3SE3044L 103742XC 103742XF 103742XL 103583 3SE3054L 103742XC 103742XF 103742XL 103583 3SEH3024L 103769XC 103769XF 103769XL 103760 3SEH30...

Страница 25: ...25 Notes ...

Страница 26: ...26 Notes ...

Страница 27: ...TION Your product is covered by a warranty www cranepumps com downloadables CATALOGS_OIPMs Warranty 24MonthWarranty pdf If you have a claim under the provisions of the warranty contact your local Crane Pumps Systems Inc Distributor ...

Отзывы: