Crane Barnes 1100EXP Series Скачать руководство пользователя страница 7

7

TROUBLE SHOOTING

CAUTION !

 Always disconnect the pump from the electrical power source before handling.

If the system fails to operate properly, carefully read instructions and perform maintenance recommendations.
If operating problems persist, the following chart may be of assistance in identifying and correcting them:

MATCH “CAUSE” NUMBER WITH CORRELATING “CORRECTION” NUMBER

.

NOTE:

 Not all problems and corrections will apply to each pump model.

PROBLEM

CAUSE

CORRECTION

Pump will not run

1.

 Poor electrical connection, blown fuse, 

tripped breaker or other interruption of power, 
improper power supply.

2.

 Motor or switch inoperative (to isolate 

cause, go to manual operation of pump).

2a.

 Float movement restricted.

2b. Switch will not activate pump or is defec-
tive.

3.

 Insuffi cient liquid level.

1. Check all electrical connections for 
security. Have electrician measure current 
in motor leads, if current is within ±20% 
of locked rotor Amps, impeller is probably 
locked. If current is 0, overload may be 
tripped. Remove power, allow pump to cool, 
then recheck current.
2a. Reposition pump or clean basin as 
required to provide adequate clearance for 
fl oat.
2b. Disconnect level control. Set ohmmeter 
for a low range, such as 100 ohms full scale 
and connect to level control leads. Actuate 
level control manually and check to see that 
ohmmeter shows zero ohms for closed switch 
and full scale for open switch. (Float Switch).
3. Make sure liquid level is at least equal to 
suggested turn-on point.
4. Recheck all sizing calculations to 
determine proper pump size.
5. Check discharge line for restrictions, 
including ice if line passes through or into 
cold areas.
6. Remove and examine check valve for 
proper installation and freedom of operation.
7. Open valve.
8. Check cutter for freedom of operation, 
security and condition. Clean cutter and inlet 
of any obstruction.
9. Loosen union slightly to allow trapped air 
to escape.Verify that turn-off level of switch 
is set so that the suction is always fl ooded. 
Clean vent hole.
10. Remove & examine for damage. Replace 
pump stator if required.
11. Repair fi xtures as required to eliminate 
leakage.
12. Check pump temperature limits & fl uid 
temperature.
13. Replace portion of discharge pipe with 
fl exible connector.
14. Turn to automatic position.
15. Check for leaks around basin inlet and 
outlets.

Pump will not turn off

2a. Float movement restricted.
2b. Switch will not activate pump or is defec-
tive.
4. Excessive infl ow or pump not properly sized 
for application.
9. Pump may be airlocked.
14. H-O-A switch  on panel is in “HAND” posi-
tion

Pump hums but does not run

1. Incorrect voltage
8. Cutter jammed or loose on shaft, worn or 
damaged, inlet plugged.

Pump delivers insuffi cient capacity

1. Incorrect voltage.
4. Excessive infl ow or pump not properly sized 
for application.
5. Discharge restricted.
6. Check valve stuck closed or installed 
backwards.
7. Shut-off valve closed.
8. Cutter jammed or loose on shaft, worn or 
damaged, inlet plugged.
9. Pump may be airlocked.
10. Pump stator damaged/torn.

Pump cycles too frequently or runs 
periodically when fi xtures are not in use

6. Check valve stuck closed or installed 
backwards.
11. Fixtures are leaking.
15. Ground water entering basin.

Pump shuts off and turns on indepen-
dent of switch, (trips thermal overload 
protector). 

CAUTION!

  Pump may start 

unexpectedly. Disconnect power supply.

1. Incorrect voltage.
4. Excessive infl ow or pump not properly sized 
for application.
8. Cutter jammed, loose on shaft, worn or 
damaged, inlet plugged.
12. Excessive water temperature.

Pump operates noisily or vibrates 
excessively

4. Operating at too high a pressure.
5. Discharge restricted.
8. Cutter broken.
13. Piping attachments to buiding structure too 
rigid or too loose.

Содержание Barnes 1100EXP Series

Страница 1: ...rogram product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 094685 Rev E Series 1100EXP 1148EXP 1 3 HP 1750 RPM 60 Hz Class I Group D Class II Groups...

Страница 2: ...Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT re...

Страница 3: ...m NEMA START CODE FULL LOAD AMPS LOCKED ROTOR AMPS A DIM B DIM C DIM 1 1100EXP 1 3 115 230 1 60 1750 P 6 4 32 0 34 56 878 24 06 611 18 00 457 1148EXP 1 3 115 1 60 1750 M 6 4 32 0 58 56 1487 48 06 1221 42 00 1067 IMPORTANT 1 PUMP MAY BE OPERATED DRY FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND OR SEALS 2 THIS PUMP IS APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS ...

Страница 4: ...ton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location These pumping units are self contained and are recommended for use in a sump or basin This pump is designed to pump effluent or wastewater nonexplosive and noncorrosive liquids that are free of solids and abrasives They are for use in hazardous residential light industrial sump applications Class l Group D Class ll Groups E F G The sump ...

Страница 5: ...prong individually If the reading is other than infinity a leakage through stator insulation or moisture in the windings is occurring and the stator must be removed dried out and rechecked A reading at zero indicates a dead short and the stator will have to be replaced DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS C 4 Operation 1 Close disconnect switch to motor 2 Briefly operat...

Страница 6: ... 3 SERIAL NUMBER The Serial Number block will consist of a six digit number which is specific to each pump and may be preceded by a alpha character which indicates the plant location This number will also be suffixed with a four digit number which indicates the date the unit was built Date Code EXAMPLE A012345 0490 Serial Number A012345 Date Code 0490 April of 1990 60 Hz Testing is performed with ...

Страница 7: ... cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits flu...

Страница 8: ...8 ...

Страница 9: ...5 1148EXP 10 1 09373 Float Copper 11 1 09354 A Volute Housing 12 3 20553 Collet 13 1 09355 A Base 14 5 08169 Cap Screw 1 4 20 x 50 Lg Bronze 15 1 23148 21 88 Column Assy 21 88 1100EXP 1 23148 45 88 Column Assy 45 88 1148EXP 16 2 23143 Bearing 17 2 23147 Pin 18 4 21236 Cap Screw 3 8 16 x 1 Lg 19 1 23208 Float Rod Bracket 20 1 09356 C Impeller 21 1 23103 A Adapter 22 1 23239 Switch Bracket 25 1 15 5...

Страница 10: ...formance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATI...

Страница 11: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Страница 12: ...Notes ...

Отзывы: