Power Safety

-

The unit is supplied with an external power supply and suitable mains lead. Only use the
supplied external power supply, however if you decide to use a mains lead of your
choice, bear in mind the following:

-

Refer to the rating label of the unit and always use a suitable mains cords.

-

The unit should ALWAYS be earthed with the earth on the IEC socket.

-

Please use compliant 60320 C13 TYPE SOCKET. When connecting to supply
outlets ensure that appropriate sized conductors and plugs are used to suit local
electrical requirements.

-

Maximum cord length should be 4.5m (15’)

-

The cord should bear the approval mark of the country it is to be used.

-

Connect only to an AC power source that contains a protective earthing (PE) conductor.

-

Only connect unit to single phase supplies with the neutral conductor at earth potential.

GB

The apparatus shall be connected to mains socket outlets with a protective earthing

connection.
DEN Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til
stikproppens jord.
FIN

Laite on lilettävä sojamaadoituskoskettimilla varustettuun pistorasiaan.

NOR Apparatet må tilkoples jordet stikkontakt.
SWE Apparaten skall anslutas till jordat uttag.

ATTENTION: Un-earthed metal parts may be present inside the enclosure. No
user serviceable parts inside - to be serviced only by qualified personnel.
When servicing, disconnect all power sources before removing any panels.

CE Certification

This unit is CE compliant. Note that any cables supplied with Cranborne Audio
equipment may be fitted with ferrite rings at each end. This is to comply with the
current regulations and these ferrites should not be removed.

FCC Certification

-

Do not modify this unit! This product, when installed as indicated in the instructions
contained in the installation manual, meets FCC requirements.

-

Important: this product satisfies FCC regulations when high quality shielded cables are
used to connect with other equipment. Failure to use high quality shielded cables or to
follow the installation instructions may cause magnetic interference appliances such as
radios televisions and will void your FCC authorisation to use this product in the USA.

-

This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and if not installed and used in accordance with the instruction
manual may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at their own expense.

500R8

Quick Start Guide

Rev02

-Page 11-

©2021 Cranborne Audio Ltd

Содержание 500R8

Страница 1: ...een carefully considered to ensure that every nuance of your 500 series module is translated into the best possible digital signal to be processed We employ converters with specifications that rival that of the best standalone units whilst being governed by our master reference grade clock featuring less than 0 5 picoseconds of jitter Cranborne Audio for us means so much more than metal boxes with...

Страница 2: ...10 General Safety 10 Installation notes 10 Power Safety 11 CE Certification 11 FCC Certification 11 RoHS Notice 12 Instructions for disposal of WEEE by end users in the European Union 12 Electromagnetic Compatibility 12 Note Before using 500R8 the correct USB output assignment must be configured within your operating system Please follow the Software Setup section of this manual to correctly assig...

Страница 3: ...s into the Blend controls for Aux and Monitor busses DAW 2 is accessed using USB outputs 29 30 or DAW 2 Jack inputs on the rear panel 5 Power Switch Safely powers on and off 500R8 as well as any inserted 500 series module Tap to power on press and hold to power off 13 Monitor Level Control Adjusts the main level of the Monitor Bus to both Monitor Headphones and Speaker Outputs 6 Level Meter Displa...

Страница 4: ...ck facility Phantom power is always ON Dynamic or Condenser mics can be used 5 ADAT I O Interfaces 16 in 16 out ADAT optical lightpipe channels directly into 500R8 s USB interface 14 Power Provides 500R8 with power via the provided external 24v 5A DC power supply No other power supply should be used 6 S PDIF I O Interfaces 2 in 2 out S PDIF and AES3 directly into 500R8 s USB interface 15 C A S T l...

Страница 5: ...ere s more to 500R8 s rack ears than meets the eye 500R8 s rack ears can be repositioned in 3 ways to suit particular applications and offer greater protection during transport Standard Standard rack ear configuration where the rack ears are mounted flush to the front panel of 500R8 Recessed Protective rack ear configuration where 500R8 is set backwards into its rack ears to protect front panel co...

Страница 6: ...fore continuing 2 Firmly touch the metal chassis of 500R8 to discharge any built up static electricity 3 Carefully pick up your 500 series module and locate its conductive edge into the backplane connector of 500R8 4 Once located push the module into place and secure the module into the rack using the supplied 4 40 screws be careful not to over tighten and strip the screw or thread Removing Module...

Страница 7: ...On 500R8 using a brief tap of the Power button Then Power On your studio monitors 5 Configure the front panel monitor controls to match the provided diagram The Aux and Monitor Blend controls should be set to 12 o clock and the DAW Select switch should be set into the up position Note Once 500R8 is connected to your speakers the Monitor Level control may seem sensitive with small movements causing...

Страница 8: ...drop down menu and select Default Device Once configured press play in any of your applications including Spotify Tidal iTunes or similar and the audio will be sent directly into 500R8 s DAW return and Monitor Outputs Increase the Monitor Level control for more volume Note If you are still unable to hear audio through 500R8 please ensure that the Speaker B Mute and Dim keys are switched off on the...

Страница 9: ...er keymat If the LED meter is indicating signal please check that the downstream connections are correct and the speakers are switched on Sample Rate Selection in MacOS Audio MIDI Setup for macOS enables you to adjust the Sample Rate settings of 500R8 when it is playing audio from Spotify Youtube and iTunes Simply select the Format drop down menu to display the possible Sample Rates from 44 1 to 1...

Страница 10: ...ong periods of time Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Do NOT modify this unit altercations may affect perf...

Страница 11: ...l When servicing disconnect all power sources before removing any panels CE Certification This unit is CE compliant Note that any cables supplied with Cranborne Audio equipment may be fitted with ferrite rings at each end This is to comply with the current regulations and these ferrites should not be removed FCC Certification Do not modify this unit This product when installed as indicated in the ...

Страница 12: ...e may be some potential safety hazard if the apparatus is operated at altitude exceeding 2000m Evaluation of apparatus based on the temperate climate conditions only There may be some potential safety hazard if the apparatus is operated in tropical climate conditions Electromagnetic Compatibility EN 55032 2015 Class B EN 55016 2 1 2009 A1 2011 EN 55016 2 3 2010 A1 2010 EN 55035 2017 EN 61000 4 2 2...