3. Installation Preparation.

page 3

4. Hanging Bracket Installation.

ON

OFF

ON

OFF

Vaulted ceiling 
angle is not to 
exceed 25 degrees.  

downrod

installation

flushmount

installation

7 feet

(2.13 m) (76 cm)

30 

inches

12 ft. - 20 ft.

(3.66 m - 6.1 m)

(3.66 m - 6.1 m)  

blade edge

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 7 feet (2.13m) from the floor and 
30 in (76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 400 square 
feet (37.2 square meters).

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling.  The 
hanging length can be extended by purchasing 
a longer downrod (0.5in. /1.27cm diameter). 
Other installation, such as

 flushmount

, is 

not

 

available for this fan.

12 f

t.

 - 20 f

t.

hanging bracket

spring washers

outlet box screws

flat washers

Turn off circuit breakers to current fixture from 
breaker panel and be sure operating light switch is 
turned to the OFF position. 

WARNING: 

Failure to disconnect power supply prior 

to installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be 

sure the outlet box is securely attached to the 
building structure and can support the full weight of 
the fan. Ensure outlet box is clearly marked "Suitable 
for Fan Support." If not, it must be replaced with an 
approved outlet box. Failure to do so can result in 
serious injury.

CAUTION

: Be sure outlet box is grounded properly 

and that a ground wire (

GREEN

 or bare) is present.

Install hanging bracket to outlet box using original 
screws, spring washers and flat washers provided 
with new or original outlet box.

If installing on a 

vaulted ceiling, face opening of hanging bracket 
towards high point of ceiling. Arrange electrical 
wiring around the back of the hanging bracket 
and away from the bracket opening.

*Note

: It is very important that you use the proper 

hardware when installing the hanging bracket as 
this will support the fan. 

Содержание MIDORO MO56

Страница 1: ...rol Assembly pg 9 Automated Learning Process Activating Code pg 10 Remote Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacements pg 11 net weight of fan 26 84 lb 12 2 kg READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE E192641 Federal regulations require ceiling fans with light kits manufactured or imported after January 1 2009 to limit total wat...

Страница 2: ...your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CUL Canada or UL USA listed and marked suitable for use with the model fan you are installing Switches must be CU...

Страница 3: ...ll control 2 pieces q plate 1 piece r remote control cover 1 piece s faceplate 3 pieces t hardware packs page 2 Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that all parts hav...

Страница 4: ...utlet box screws flat washers Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and can sup...

Страница 5: ...usly removed Tighten yoke set screws and nuts securely Refer to diagram 2 Slide yoke cover and canopy over downrod Refer to diagram 3 Thread safety cable and wires through hanging ball then slide hanging ball over downrod the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of downrod and raise hanging ball Be sure stop...

Страница 6: ...l slot until it lines up with the hanging bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or death Tip Seek the help of another person to hold the stepladder in place and to help lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will...

Страница 7: ...onnector separately with electrical tape as an extra safety measure Gently push wires and taped wire connectors into outlet box Install one 12 volt battery included in wall control IMPORTANT Wall control will not function unless battery is installed Since this fan comes with incandescent bulbs the dimmer switch labeled DIM and ON has been pre set to the ON position DIM If you do not wish to have d...

Страница 8: ... can be set on each blade screw prior to installing blades Locate 15 blade attachment screws and washers in hardware pack Slide blade through one of the narrow rectangular openings on motor housing aligning holes in blade with holes in blade arm located on the underside of the motor housing refer to drawing at right Insert 3 blade attachment screws along with washers with fingers first and then ti...

Страница 9: ...emoved and securely tighten all 3 screws with a Phillips screwdriver Refer to diagram 2 IMPORTANT Be careful when attaching threaded rod assembly that the wiring does not get pinched or caught under the metal edges Allow wires to come through corresponding openings in plate on threaded rod assembly Install 2 candelabra base 60 watt max bulbs included Important When replacing bulb s please allow bu...

Страница 10: ... have dimming capability please move the switch to the OFF position ON OFF Refer to diagram 2 Attach black faceplate to front of wall control press down firmly Refer to diagram 3 Align holes in wall control with posts located on inside of TOP part of remote control cover and press together firmly Place wall control into BOTTOM part of remote control cover aligning posts in top of remote control co...

Страница 11: ...ion ON OFF slider switch turns wall control ON or OFF switch not functional on handheld remote HIGH button turns fan to HIGH speed MED button turns fan to MEDIUM speed LOW button turns fan to LOW speed OFF button turns fan OFF L1 button not applicable for this fan L2 button turns light kit ON OFF when pressed once dims light kit when pressed and held down REV button used to REVERSE blade direction...

Страница 12: ...ly 2 Check that wires in canopy are wired properly 3 Replace defective bulb with same type of bulb 4 Verify that molex connections in light kit fitter are connected properly Problem Fan and light fail to operate with wall control optional and or handheld remote control Solutions 1 Check battery power in handheld remote control 2 Learning process between fan handheld remote control and if applicabl...