Fig.6-26 Simple PLC operation diagram
Code
Name
Setting Range
FA.35
Simple PLC status saving after power off
0
~
1
【
0
】
0:Power loss without memory
1:Power loss memory
PLC record the running stage and frequency when power loss.
Code
Name
Setting Range
FA.36
Simple PLC restart selection
0
~
1
【
0
】
0: Restart from step 0
If the inverter stops during running (due to stop command or fault),it will run from step
0 when it restarts.
1:Continue from interrupted step
If the inverter stops during running (due to stop command or fault), it will record the
running time of current step. When inverter restarts,it will resume from interrupted time
automatically.
Code
Name
Setting Range
FA.37
Time unit
0
~
1
【
0
】
0:Seconds