Страница 1: ...Before using this product read this manual and follow all its Safety Rules and Operating Instructions Safety Instructions Installation Operation Maintenance Storage Troubleshooting Guide Parts List Sears Brands Management Corporation Hoffman Estates IL 60179 U S A www sears com craftsman 9 08 2011 Part No 101 3344 ...

Страница 2: ...or workmanship Defective product will receive free repair or free replacement if repair is unavailable For warranty coverage details to obtain repair or replacement visit the web site www craftsman com This warranty does not cover the air filter or drive belt which are expendable parts that can wear out from normal use within the warranty period This warranty is void if this product is ever used w...

Страница 3: ... amps available a larger circuit must be used Always use more air hose before utilizing extension cords All exten sion cords used must be 12 gauge with a maximum length of 25 ft The circuit fuse type must be a time delay Low voltage could cause damage to the motor If the air compressor is in operation all guards and covers should be attached or installed correctly If any guard or cover has been da...

Страница 4: ...he tank develops a leak then replace the air compressor Never use the air com pressor after a leak has been found or try to make any modifications to the tank Never modify the air compressor s factory settings which control the tank pressure or any other function Specifications Pump Oil Free Direct Drive Motor 1 5 HP Bore 2 48 Stroke 0 87 Voltage Single Phase 120 VAC Minimum Circuit Requirement 15...

Страница 5: ...coming from the air tank is controlled by the regulator To increase the pressure turn the knob clockwise and to decrease the pressure turn the knob counter clockwise Pressure Switch This controls the power to the motor and also the cut in cut out pressure settings This switch serves as the Auto On Off positions for the unit F I Pressure Relief Valve The pressure relief valve located on the side of...

Страница 6: ...h a qualified electrician or service personnel if these instructions are not completely understood or if in doubt as to whether the tool is properly grounded Plug Grounded Outlet Grounding Pin _l_fdAVlhV e Improper installation of the grounding plug will result in a risk of electric shock If repair or replace ment of the cord or plug is necessary do not connect the grounding wire to either flat bl...

Страница 7: ...hen shut off automatically 7 Adjust the regulator to a PSi setting that is needed for your application and be sure it is within the safety standards required to perform the task if using a pneumatic tool the manufacturer should have recommendations in the manual for that particular tool on operating PSi settings 8 The air compressor is now ready for use Daily Shut Down Procedures 1 Set the Auto Of...

Страница 8: ...Off switch in the on position To ensure efficient operation and longer life of the air compressor unit a routine maintenance schedule should be followed The following schedule is geared toward a consumer whose compressor is used in a normal working environ ment on a daily basis _e Y llji e _Vl From time to time the air filter needs to be removed and cleaned 1 Turn the air compressor off 2 Unplug t...

Страница 9: ... minimal pressure loss during initial use of the tool Move the Auto Off lever to the Off position If the unit doesn t shut off unplug it from the power source and contact a service technician Make sure power cord is plugged in and the switch is on Inspect for the proper size fuse in your circuit box If the fuse was tripped reset it and restart the unit If repeated tripping occurs replace the check...

Страница 10: ...Craftsman Air Compressor Model 921 164710 Exploded View s_ 6_ 10 ...

Страница 11: ...Craftsman Air Compressor Model 921 164710 Exploded View 454 11 ...

Страница 12: ...pple 1 4 mnpt x 2 35mm 15 7 E104779 Shroud MotorEnd Cap 16 7 Motor Pump F2 17 3 7 Assy Eccentric and Bearing 6203ZC3 18 3 7 Screw SHCS M6 X 1 X 35mm 19 2 7 Nut M5 X 0 8 20 2 7 Screw SHCS M5 X 0 8 X 25ram 21 2 7 Rod Connector 22 2 7 Ring Piston 23 2 7 Cap Piston 24 2 7 Screw M5 X 0 8 X 15ram 25 4 Fan Pump Cooling 26 4 Washer Flat M6 27 4 Washer Lock M6 28 4 Screw SHC M6 x 1 0 x 16ram Left Hand Thre...

Страница 13: ... 1 4 2 70 9 Ferrule 1 4 2 1 71 E101362 Valve Check 90 Degree Left 72 Bolt HFH M8 X 1 25 X 25MM Note Any part kit number field without a number is not available Descriptions are provided for reference only The Kit column represents that the part being offered is available in a kit One of each part per kit will be offered Kit number and parts that are included are as follows Part No Description Refe...

Страница 14: ......

Страница 15: ...to lea este manual y siga sus reglas e instruc clones de seguridad Instrucciones y pautas de seguridad importantes Instalaci6n y ensamblaje Procedimientos de operaci6n MantenimientoyAImacenamiento Diagn6stico y correcci6n de fallas Lista de las piezas Sears Brands Management Corporation Hoffman Estates IL 60179 ETA TS UNIS www sears com craftsman ...

Страница 16: ...era repare gratuitement ou remplace sans aucuns frais s il est impossible de le reparer Pour obtenir de plus amples details au sujet de la couverture de la garantie savoir comment obtenir une reparation ou un remplacement visitez le site web www craftsman com Cette garantie ne couvre pas le filtre air ou la courroie d entrainement qui sont des pieces consomptibles qui peuvent s user Iors d une uti...

Страница 17: ... de mayor capacidad Si es necesario antes de emplear una extension electrica aSada una manguera de aire mas larga Las extensiones electricas deben set de calibre 12 y tener una Iongitud maxima de 7 6 metros El fusible del circuito debe ser de accion retardada Un voltaje demasiado bajo puede daSar el motor Antes de operar el compresor todos los protectores y cubiertas deben estar instalados correct...

Страница 18: ...izacion Si el tanque tiene una fuga reemplace el compresor No utilice el compresor si se ha detectado una fuga ni trate de modificar el tanque Nunca modifique los ajustes de fabrica del compresor que controlan la presi6n del tanque y demas funciones Especificaciones Bomba Sin aceite De impulsi6n directa Motor 1 5 HP Di_metro 63 mm Carrera 22 mm Voltaje monofasico 120 VAC Capacidad minima del circu...

Страница 19: ...pot el regulador Para aumentar la presiOn gire la perilla en direcciOn de las manecillas para disminuirla gire la perilla en direcciOn contraria alas manecillas Interruptor de presion Controla el suministro electrico en el motor y tambien los ajustes de presiOn de arranque y presi6n de parada Este inter ruptor sirve como posiciOn de autoencendido y apagado Auto On Off de la unidad I Valvula de ali...

Страница 20: ...un electricista o agente de servicio calificado si no entiende completamente estas instrucciones o si tiene dudas sobre la correcta puesta a tierra de la herramienta Clavija Terminal de tierra Tomacorrientes con conexidn a tierra _ _fe rJ l l V t Una conexi6n a tierra inadecuada puede provocar una descarga electrica Si necesita reparar o cambiar el cable o la clavija no conecte el alambre de tierr...

Страница 21: ...ire en el tanque hasta Ilegar a la presi6n de apagado momento en el cual se apagar de manera autom_tJca 7 Ajustar el regulador a un valor de bar psi que sea necesario para el uso previsto y verfficar que est_ dentro de los est ndares de segurJdad requeridos para realizar la tarea Si se utiliza una herramienta neum tica el fabricante debe haber incluido en el manual de dicha herramienta valores rec...

Страница 22: ...miento del filtro de aire 5 Haga pasar el aire comprimido a traves del filtro de aire durante 10 15 segundos Asuntos para verificar cambiar Revisar la valvula de seguridad del tanque Revisar visualmente el aspecto general de la unidad Drenar el tanque Verificar el nivel del aceite Antes de cada uso o diariamente X X X X NOTA El motor reiniciara automaticamente sin la advertencia si la unidad es de...

Страница 23: ...o Si la unidad no se apaga desconectela del tomacorriente y comuniquese con un tecnico de servicio Compruebe que el cable de corriente esta enchufado y que el interruptor esta encendido Compruebe que el fusible de la caja de circuitos sea de la capaci dad adecuada Si se ha disparado restablezcalo y rearranque la unidad Si el fusible se dispara con frecuencia revise la valvula de retencion o Ilame ...

Страница 24: ...Compresor de aire Modelo 921 164710 Vista esquematica 24 ...

Страница 25: ...Compresor de aire Modelo 921 164710 Vista esquematica 47 4 55 54 25 ...

Страница 26: ...42 0 8 X 25 mm E104273 E104272 E100300 E103967 E101490 E103744 E102822 E101073 E101800 E100971 E100594 Tornillo SHC M6 x 1 0 x 16 mm rosca a izquierdas Capacitor de funcionamiento motor 50 pF 250 VCA montura de soporte Capacitor de arranque motor 250 pF 125 VCA montura de soporte N A N A Guardera trasera completa Mango Empufiadura de la manija Manometro de 2 pulgadas carcasa negra esfera blanca Co...

Страница 27: ...tro de aire 4 67 8 Tapa del filtro de aire 2 68 9 Tubo de desahogo de 1 4 de pulgada de cobre estampado F2 en 400 MM vert 10 69 9 Tuerca comp de 1 4 de pulgada 8 70 9 Ferula de 1 4 de 1 pulgada 71 E101362 Wlvula de retencion 1 90 grades a la izquierda 1 72 Perno HFH M8 X 1 25 1 X 25 MM 64 Nota Cualquiercampopara los nt_meros juegos de piezasque notenganun ntJmem especfficode pieza indicaque no est...

Страница 28: ...ms lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytime day or night U S A on y www sears com To purchase a protection agreement on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada ii Parapedir serviciode reparaci6n Au Canada pourservice en fran_ais a domicilio y paraordenar piezas 1 800 LE FO...