19 - ENG
PrOBLeM
CAUSE
CORRECTION
Pressure read-
ing on the regu-
lated pressure
gauge drops
when an acces-
sory is used.
It is normal for "some"
pressure drop to occur.
If there is an excessive
amount of pressure drop when
the accessory is used, adjust
the regulator following the
instructions in the
Description
of Operation
paragraph in the
Operation
section.
NOTE:
Adjust the regulated
pressure under flow
conditions (while accessory is
being used).
Knocking Noise. Possible defect in safety
valve.
Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.
Defective check valve.
Replace check valve.
Compressor is
not supplying
enough air
to operate
accessories.
Prolonged excessive use of
air.
Decrease amount of air usage.
Compressor is not large
enough for air requirement.
Check the accessory air
requirement. If it is higher than
the SCFM or pressure sup-
plied by your air compressor,
you need a
larger com-
pressor.
Hole in hose.
Check and replace if required.
Check valve restricted.
Replace check valve.
Air leaks.
Tighten fittings.
Restricted air intake filter.
Clean or replace air intake
filter. Do not operate the
air compressor with the fil-
ter removed. Refer to the
Air Filter paragraph in the
Maintenance
section.
Regulator knob
has continuous
air leak.
Damaged regulator.
Replace.
Regulator will
not shut off air
outlet.
Damaged regulator.
Replace.
Содержание 919.167551
Страница 21: ...21 NOTES NOTAS ...
Страница 41: ...45 NOTES NOTAS ...
Страница 42: ...46 NOTES NOTAS ...