background image

Содержание 580.323602

Страница 1: ... and Operating instructions PRECAUC_ON Antes de utilizar el producto lea este manual y siga todas las Reglas de Seguridad e Instrucciones de Uso Sears Roebuck and Co Hoffman Estates _L 60179 U S A Visit our Craftsman website www craftsmamcom Part No 193353GS Draft9 07192005 o Safety o AssemNy o Operation o Maintenance o Parts o EspaSoN ...

Страница 2: ...set alternator or engine or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading over speeding improper maintenance repair or storage so as in SEARS s judgment to adversely affect its performance and reliability NORMAL WEAR As with all mechanical devices engines need periodic parts service and replacement to perform well This...

Страница 3: ...marine applications Failure to use the appropriate U S Coast Guard approved generator could result in bodily injury and or property damage Hazard Symbols and Meanings Electrocution Electrical Shock Electrical Shock Explosion Fire Toxic Fumes Hot Surface Kickback WARNING Operate generator ONLY outdoors Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other...

Страница 4: ...dequate cooling maintenance and servicing In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lands If you equip the muffler with a spark arrester it must be maintained in effective working order You can order a spark arrester through your authorized Sears service dealer...

Страница 5: ...240 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Protects engine by filtering dust and debris out of intake air CircuEt Breakers Each receptacle socket is protected against electrical overload with push to reset circuit breakers Fuel Tank Tank holds 4 U S gallon of unleaded fuel Spark Attester Muffler Grounding Fastener Grounding Fastener If requ...

Страница 6: ...3mm sockets a 15 16 wrench and a needle nose pliers to install this kit Install the Wheel Kit as Follows 1 Place bottom of generator cradle on a flat surface 2 Place axle stud through wheel retainer on cradle frame as shown below 3 Use 15 16 wrench to secure axle stud to frame with 5 8 18 jam nut 4 Install other axle stud in same manner NOTE Be sure to install wheel with raised hub inboard 5 Tip u...

Страница 7: ... check oil level NOTE You may not need to use all the supplied oil 6 Replace and tighten dipstick NOTE Check oil often during engine break in Add Fue WARNING WHEN ADDING FUEL Turn generator OFF and let it coo at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fil fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion Keep fue away from sparks ...

Страница 8: ...und circuit fault interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or othep vise damaged DO NOT operate generator in the rain DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT al...

Страница 9: ...ils to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil rotection device WARNING DO NOT touch hot surfaces Allow equipment to coo before touching The generator must be at bast 5 feet from structures having combustible wails and or other combustible materials Keep at least 3 feet of c...

Страница 10: ...ase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current 120 240 Volt AC 20 Amp Receptacle This is a full capacity receptacle it can supply the generator s full rated output from this sole outlet The outlet is protected by two 15 Amp push to reset circuit breakers 4 Wire Cord Set J Neutral Y Hot X Hot NEMA L14 20 _7 Ground Green A NEMA L14 20 plug is used with this 240 V...

Страница 11: ...or a more permanent shelter build a structure that wiJl enclose three sides and the top of the generator 7 Make sure entire muffler side of generator is exposed as shown previously IMPORTANT The generator must be at least 5 ft 152 cm from structures having combustible walls and or other combustible materials Leave at least 3 ft 92 cm all around generator including overhead for adequate cooling mai...

Страница 12: ... is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 a...

Страница 13: ...ric pressure humidity fuel engine lubrication maximum governed engine speed individual engine to engine variability design of the particular peice of power equipment the manner in which the engine is operated engine run in to reduce friction and clean out of combustion chambers adjustments to the valves and carburetor and other factors The power ratings may also be adjusted based on comparisons to...

Страница 14: ...MiSSiON CONTROL Maintenance replacement or repair of the emission control devices and systems may be performed by any non road engine repair establishment or individual GENERATOR MAINTENANCE Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooli...

Страница 15: ...ent plug 5 Install spark plug and tighten firmly NOTE You can purchase a new spark plug by calling 1 800 366 PART Service Air Cleaner Your engine will not run properly and may be damaged if you run it with a dirty air cleaner Replace the air cleaner every 25 hours of operation or once each year whichever comes first Replace more often if operating under dirty or dusty conditions To service the air...

Страница 16: ...ral lawsapply on federal lands If you equip the mufflerwith a spark arrester it must be maintainedin effectiveworking order if you use your generator on any forest covered brush covered or grass covered unimproved land it must have a spark attester The spark attester must be maintained in good condition by the owner operator Clean and inspect the spark attester as follows 1 To remove muffler heat ...

Страница 17: ...e in tank Drain fuel tank outdoors Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke Protect Fuel System 1 Remove all gasoline from fuel tank to prevent gum deposits from forming on these parts and causing possible malfunction of engine 2 Run engine until engine stops from lack of fuel Change OH While engine is still warm drain oi...

Страница 18: ...ity Set switch to On Turn fuel valve to Open position 3 Dirty air cleaner 4 Out of gasoline 5 Stale gasoline 3 Clean or replace air cleaner 4 Fill fuel tank 5 Drain gas tank and carburetor fill with fresh fuel Engine lacks power to spark plug 7 Bad spark plug 8 Water in gasoline Spark plug wire not connected 9 Flooded 6 Connect wire to spark plug 7 Replace spark plug 8 Drain gas tank and carbureto...

Страница 19: ...PI 2 P_ER 10blYO_ 22 15A IP zzpi 4 C_2 19 ...

Страница 20: ...CRAFTSMAN 3600 Watt AC Generator 580 323602 Main Unit _ Exploded View 4 52 58 25 24 1 22 4 I0 7 900 15 31 2O ...

Страница 21: ... 5 16 24 x 3 4 SEMS HHCS 5 16 24 x 7 7 8 Lg KIT Muffler Bracket w Hardware GASKET Exhaust MUFFLER SHCS M6 1 0 x 20 SCREEN Spark Arrest DECAL Ground KIT Vibration Mount SCREW Wing M6 1 0 x 16 SCREW 10 16 x 3 4 Self Drill SHIELD Heat CAP TAPTFE M5 0 8 x 10 Lg DECAL Caution Hot Muffler COVER Bearing Carrier with Cap KIT Hose Fuel HHCS 12 14 x 7 8 Self Driller KIT Fuel Tank Hardware KIT Valve Tank ASS...

Страница 22: ...5 16 22694GS 17 Description KIT Cover Control Panel CONTROL PANEL Compact OUTLET 120V 20A Duplex NUT Palnut Pushnut 5 32 CAP Circuit Breaker BREAKER Circuit OUTLET 120 240V Locking 20A NUT Palnut Pushnut 3 16 SCREW Phillips Head M3 0 5 x 18 BAR Retaining COVER Back Control Panel SCREW Self Tapping 3 x 18 HOUSING Receptacle SCREW 3 5 x 14 z Items without part numbers are common fasteners and are av...

Страница 23: ... 13 8 Part 186059GS 191685GS 191686AGS 186060GS 86308GS 91825GS 66849GS 22694GS 81917GS 193428AGS 194274GS Description ADAPTER Mounting Alternator ROTOR STATOR RBC with O Ring p n 189197GS HHCS M6 1 0x 115 SEMS ASSY Holder Rectifier Brush TAPT TE M5 0 8 x 16 RECEPTACLE 6 pin PIN Roll 4mm x 10 ASSY Wire Ground HARNESS Wire Power 23 ...

Страница 24: ...dle Includes item 11 2 94034GS LEG Mounting 3 52858GS NUT Locking Hex M8 1 25 4 HHCS M8 1 25 x 45 5 93728GS AXLE 6 197061GS WHEEL 7 87005AGS PIN 8 WASHER Flat M12 9 94222QGS NUT 518 18 Jam Lock 10 HHCS M8 1 25x20 11 189718GS GRIP Handle _ items without part numbers are common fasteners and are available at local hardware stores 24 ...

Страница 25: ...ENGINE_ 7 0 HP Briggs and Stratton 120312 Exploded View 40 35 238 36_ 83O 746 742_ _ 24_ 332 Y 522 2_ 22 21 o 718 25 ...

Страница 26: ... HP Bdggs and Stratton 120312 Exploded View 163 633 95 _ 51 365 977 CARBURETOR GASKET SET 276 51 163_ _ 633A 633 12t 0 CARBURETOR OVERHAUL KUT 633A 633 276 445 161 968 425_ _ 358 ENGUNE GASKET SET 12 1022 868 26 ...

Страница 27: ...ENGINE_ 7 0 HP Briggs and Stratton 120312 Exploded View 604 286 364 347_ 584_ 564A 37 23 455 332_ 334_ 1305 ss_ t211 55 6_ 1095 VALVE GASKET SET 10 51 27 ...

Страница 28: ...d 868 692044 118 695042 Jet Main High Altitude 914 699481 121 696998 Kit Carburetor Overhaul 9 4A 692557 122 693749 Spacer Carburetor 914B 691686 125 698810 Carburetor 968 698811 130 691203 Valve Throttle 971 690370 133 398187 Float Carburetor 975 493640 134 398188 Valve Float Needle 977 696997 137 693981 Gasket Float Bowl 993 694088 146 690979 Key Timing 1005 692592 155 698214 Plate Cylinder Head...

Страница 29: ...29 ...

Страница 30: ... days if you have any questions regarding your warranty rights and responsibilities you should contact a Sears Service Representative at 1 800 469 4663 Sears Emission Controt Defects Warranty Provisions The following are specific provisions relative to your Emission Control Defects Warranty Coverage 1 Warranted Parts Coverage under this warranty extends only to the parts listed below the emission ...

Страница 31: ...the Emissions Durability Period of an engine with an intermediate rating would equate to 10 to 12 years The Air hdex is a calculated number describing the relative level of emissions for a specific engine family The lower the Air Index the cleaner the engine This information is displayed in graphical form on the emisions labe Emissions Compliance Period On Engine Emissions Compliance Label After J...

Страница 32: ...ntenimiento y servicio normal y no se aplica a generadores altemadores motores o partes que hayan sido sujetos a instalaciones o modificaciones incorrectas o no autorizadas mal uso negligencia accidente sobrecarga exceso de velocidad mantenimiento reparacion o almacenamiento incorrecto que a juicio de SEARS afecte negativamente su funcionamiento y confiabilidad DESGASTE NOR VIAL Como con todos los...

Страница 33: ... un generador no homologado por cuerpo de guardacostas de EE UU puede provocar lesiones y daffos materiales Sirnbolos de Peligro y Significados Electrocutamiento Descarga Electrica Descarga Electrica Explosi6n Fuego Gases T6xicos Superficie Caliente Retroceso ADVERTENCIA Opere et generador SOLAMENTE al aire libre AsegQrese de que los gases de escape no puedan entrar por ventanas puertas tomas de a...

Страница 34: ...e 92 cm 3 pies atrededor de ta carcasa del generador para facilitar la ventilaci6n y et mantenimiento del generador En el estado de California es obtigatorio segOn ta ley et uso de apagachispas Secci6n 4442 det C6digo de Recursos POblicos de California Otros estados pueden tener teyes similares Las leyes federales se aptican en tierras federates Si equipa el silenciador con un apagachispas este de...

Страница 35: ...n funcionamiento Palanca del Cebador o Usada cuando se esta dando arranque a un motor frio Silenciador Apagachispas El silenciador disminuye el ruido de motor y esta equipado con una pantalla apagachispas Tape del Dep6sito del Aceite Liana ei motor con aceite aquL Vea la pagina 37 para las recomendaciones del aceite Silenciador Apagachispas Tuerca Mariposa de Conexion A Tierra Tanque de Combustibl...

Страница 36: ...a 15 16 llave inglesa y unas pinsas de punta para instalar el juego de ruedas Instale emJuego de Ruedas Como Sigue 1 Coloque e fondo de la camilla de generador en una superficie plana 2 Coloque sementa de eje por iguala de rueda en el marco de curia 3 Uso 15 18 la Ilave inglesa asegurar el semental de eje para encuadrar con nuez de mermelada 5 8 18 4 Instale el otro semental de eje en la misma man...

Страница 37: ...vise el aceite frecuentemente durante e despegue del motor Agregue Combustible ADVERTENCIA CUANDO ANADA COMBUSTIBLE Apague el generador posici6n OFF y dejelo enfriar al menos pot 2 minutos antes de remover la tapa de la combustible Afloje ta tapa lentamente para dejar que la presi6n salga del tanque Llene et dep6sito de combustible a ta intempede NO Ilene demasiado et tanque Permita al menos espac...

Страница 38: ... sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o receptacutos NO use un generador con cables et6ctricos que est6n malgastados rotos pelados o da_ados de cuatquier forma NO opere et generador bajo la Ituvia NO maneje el generador o cables electricos mientras est6 parado en agua descatzo o cuando las manos y los pies est6n mojados NO pe...

Страница 39: ...ancador pero no sigue funcionando o si la unidad se para en funcionamiento asegOrese de que la unidad esta en una superficie plana y compruebe que el nivel de aceite del cigOefial es correcto La unidad puede equiparse con un dispositivo de protecci6n de bajo nivel de aceite ADVERTENCIA NO toque las superficies catientes Permita que el equipo se enfrie antes de tocado El generador debe estar situad...

Страница 40: ...e requieran hasta 2 400 vatios 2 4 kW a 20 Amperios de corriente i Tomacorriente de 120 240 Vo tios AC 20 Arnperios Este es un tomacorriente de capacidad total Io que significa que usted puede tomar e vatiaje nominal total de este solo tomacorriente Este es una tomacorriente tipo NEMA L14 20 La toma esta protegida por dos cortacircuitos de 20 Amperios con dispositivo de reposici6n _go de Cable de ...

Страница 41: ...n mas permanente construya una estructura que rodee los tres lados y la parte superior de generador 7 AsegOrese de que quede expuesto e lado completo del silenciador del generador como se muestra MPORTANTE El generador debe estar situado a un m nimo de 152 cm 5 pies de toda estructura con muros combustibles y o otras materias combustibles Mantenga un m nimo de 92 cm 3 pies alrededor del generador ...

Страница 42: ...gas como se describe a continuaci6n 1 Sin tener nada conectado al generador encienda el motor de la manera descrita en este manual 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la proxima carga 5 De nuevo permit...

Страница 43: ...axima controlada de motor variaciones entre distintos motores del mismo modelo disefio del equipo mecanico utilizado manera de hacer funcionar el motor rodaje de motor para reducir la friccion y limpiar las camaras de combusti6n ajustes de las valvulas y el carburador etc Los valores de potencia nominal tambien se puede ajustar en funcion de las comparaciones con otros motores similares utilizados...

Страница 44: ...duo especializado en la reparacion de motores que no sean de automoci6n puede encargarse deJ mantenimiento la sustitucion y la reparaci6n de los dispositivos y sistemas de control de emisiones Mantenimiento de Generador El mantenimiento del generador consiste en conservar la unidad limpia y seca Opere y almacene la unidad en un ambiente limpio y seco donde no sera expuesta al polvo suciedad humeda...

Страница 45: ...amente y puede darharse si usted Io hace funcionar con un depurador de aire sucio Suministre servicio al depurador de aire una vez cada 25 horas de operaci6n o una vez pot afio Io que suceda primero Suministre servicio mas frecuentemente si la unidad funciona bajo condiciones de mucha suciedad o polvo Los repuestos se encuentran disponibles en su centro de servicio local Sears Para dar servicio al...

Страница 46: ...ordenar et apagachispas a trav6s de su distribuidor de servicio autorizado Sears NOTA Usted puede comprar los apagachispas a traves nuevos I amando al 1 800 366 PART El generador tendra que tener un apagachispas si Io usa en terrenos no tratados cubiertos de monte maleza o pasto El apagachispas debera set mantenido en buenas condiciones por parte de propietario operador Limpie e inspeccione eJ apa...

Страница 47: ... salga del tanque Vacie el dep6sito de combustible a ta intemperie Mantenga la combustible alejada de chispas llamas abiertas pilotos calory otras fuentes de igniciSn NO encienda un cigarriito o fume Proteja el Sistema de CombustiMe Retire toda la combustible de tanque de combustible para evitar que se formen dep6sitos de goma en estas partes y causen posible real funcionamiento del motor Haga fun...

Страница 48: ...n la Planta de Servicio de Sears 1 Coloque el interruptor en On En 2 Gire la v lvula del combustible a la posicion On 3 Limpie o reemplace e depurador de aire 4 Llene el tanque de combustible 5 Drene el tanque de combustible 116nelo con combustible fresco 6 Conecte el alambre a la bujia 7 Reemplace la bu a 8 Drene el tanque de combustible 116nelo con combustible fresco 9 Exceso de cebado 10 Mezcla...

Страница 49: ...49 ...

Страница 50: ...onable_ que no exceder_ de 30 d as Si tiene alguna pregunta con respecto a sus derechos y responsabilidades para la garanga_ p6ngase en contacto con un representante de servicio Sears a 1 800 469 4663 Disposiciones de la garant a de Sears contra defectos en et control de emisiones Las siguientes son disposiciones espec ficas relacionadas con la cobertura de la garantfa contra defectos en el contro...

Страница 51: ... clasificaci6n intermedia equivaldria a 10 12 aSos El indice de Aire es un valor calculado que indica el nivel relativo de emisiones de una gama concreta de motores Cuanto menor es el indice de Aire mas limpio es el motor Esta informacion se presenta en forma gr fica en la etiqueta de emisiones Periodo de Cump_imiento de _a Normativa de Emisiones en ia Etiqueta de CumpHmiento de Emisiones dem Moto...

Страница 52: ...ke vacuums lawn equipment and electronics call or go on line for the nearest Sears Parts Repair Center 1 800 488 1222 Anytime dayor night U S A only www sears com To purchase a protection agreement U S A or m intenanc agreement Canada on a pro uct terviced by Sears 1 800 827 6 55 U S A 1 800 361 6665 Canada Para pedir servicio der paraci6n AuCanada poos rvice f an ais a domicilio y para ordenar pi...

Отзывы: