background image

 

OPERATING INSTRUCTIONS 

Power 

1.  The meter is powered by one (1) 9V battery. 

IR Measurements 

1.  Hold the meter by its handle and point it toward the surface to be measured. 
2.  Pull and hold the trigger to turn the meter on and begin testing. The temperature reading, the 

flashing ‘SCAN’ icon, the emissivity, the unit of measure and other icons as shown in the 
Display Description will appear. Note: Replace the meter’s 9V battery if the display does not 
switch on. 

3.  Release the Trigger and the reading will hold for approximately 8 seconds (HOLD will appear on 

the LCD) after which the meter will automatically shut off. 

Temperature units 

With the trigger pressed, press the ºF/ºC button to select the temperature units. 

Backlight/Laser Pointer 

With the trigger pressed:

 

1.  Press the 

  button once to change the state of the backlight (On or Off). When the laser is 

on the laser icon will appear in the display.

 

2.   Press the 

  button again to change the state of the backlight (On or Off).

 

IR Measurement Notes 

1.  The object under test should be larger than the spot (target) size calculated by the field of view 

diagram (printed on the side of the meter and in this guide). 

2.  Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 
3.  If an object's surface is highly reflective, apply masking tape or flat black paint to the surface 

before measuring. Allow time for the paint or tape to adjust to the temperature of the surface it is 
covering. 

4.  Measurements through transparent surfaces such as glass may not be accurate. 
5.  Steam, dust, smoke, etc. can obscure measurements. 
6.  The meter automatically compensates for deviations in ambient temperature. However, it can 

take up to 30 minutes for the meter to adjust to extremely wide changes. 

7.  To find a hot spot, aim the meter outside the area of interest then scan across (in an up and 

down motion) until the hot spot is located. 

Содержание 50455

Страница 1: ...er MODEL 50455 Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com craftsman 081611 CAUTION Read understand and follow Safety Rules and Operating Instructions in this manual before using this product Safety Operation Maintenance Español ...

Страница 2: ...cations 3 Controls 4 Display Description 4 Battery Installation 4 Operating Instructions 5 Power 5 Non Contact IR Temperature Measurements 5 Temperature Units 5 Backlight and Laser Pointer 5 IR Measurement Notes 5 Field Of View 6 Troubleshooting 6 Service and Parts 6 ...

Страница 3: ...r beam is on DO NOT point the beam toward anyone s eye or allow the beam to strike the eye from a reflective surface DO NOT use the laser near explosive gases or in other potentially explosive areas SPECIFICATIONS Range 4 to 500 F 20 to 260 C Resolution 0 1 Accuracy 4 to 20 F 20 C to 7 C 7 5 F 4 C 20 to 500 F 7 C to 260 C 3 of reading or 5 F 2 5 C whichever is greater Note Accuracy is specified fo...

Страница 4: ...rigger is depressed 2 Displays HOLD when trigger is released 3 Laser pointer ON 4 Emmisivity setting 0 95 5 Temperature units 6 Low battery 7 Max Min display 8 Temperature display BATTERY INSTALLATION When the low battery symbol appears on the LCD replace the meter s battery 9V The battery compartment is located in the rear of the handle Open the compartment by carefully pulling the panel down The...

Страница 5: ...the laser is on the laser icon will appear in the display 2 Press the button again to change the state of the backlight On or Off IR Measurement Notes 1 The object under test should be larger than the spot target size calculated by the field of view diagram printed on the side of the meter and in this guide 2 Before measuring be sure to clean surfaces that are covered with frost oil grime etc 3 If...

Страница 6: ... light In addition the spot size may be so large that it encompasses surface areas not intended to be measured TROUBLESHOOTING There may be times when your meter does not operate properly Here are some common problems that you may have and some easy solutions to them Meter Does Not Operate 1 Always read all the instructions in this manual before use 2 Check to be sure the battery is properly insta...

Отзывы: