background image

5

!

•  Should a hydraulic hose ever rupture, burst or

need to be disconnected, immediately shut off the
pump and release all pressure. Never attempt to
grasp a  leaking pressurized hose with your
hands. The force of escaping hydraulic fluid can
inflict injury.

• Do not subject the hose to potential hazard such

as fire, sharp objects, extreme heat or cold, or
heavy impact.

• Do not allow the hose to kink, twist, curl, crush,

cut or bend so tightly that the fluid flow within the
hose is blocked or reduced. Periodically inspect
the hose for wear, because any of these
conditions can damage the hose and possibly
result in personal injury.

• Do not pull, position or move setup by the hose.

Doing so can damage the hose and possibly
cause personal injury.

• Hose material and coupler seals must be

compatible with hydraulic fluid used. Hoses also
must not come in contact with corrosive materials
such as battery acid, creosote-impregnated
objects and wet paint. Hose deterioration due to
corrosive material can  result in personal injury.
Never paint a coupler or hose.

• The user must be a qualified operator familiar with

the correct operation, maintenance, and use of
rams. Lack of knowledge in any of these areas
can lead to personal injury.

• Use only approved accessories and approved

hydraulic fluid.

• Do not exceed the rated capacity of the ram.
• Inspect each ram and coupler before each use to

prevent unsafe conditions from developing.

• Do not use rams if they are damaged, altered or

in poor condition.

• Do not use rams with bent or damaged coupler or

damaged threads.

• Under certain conditions, the use of an extension

with a hydraulic ram may not be advisable and
could present a dangerous condition.

• Avoid pinch points or crush points that can be

created by the load or parts of ram.

• To help prevent material fatigue if the ram is to

be used in a continuous application, the load
should not exceed 85% of the rated capacity.

• Ram must be on a stable base which is able

to support the load while pushing or lifting.

• Ensure ram is fully engaged into/onto adapters,

extension accessories.

• To help prevent personal injury, use shims, friction

material or constraints to prevent slippage of the
base or load.

• Do not off-center loads on a ram. The load can tip

or the ram can "kick out" and cause personal
injury.

• As the load is lifted, use blocking and cribbing to

guard against a falling load.

• Never allow personnel to work on, under or around

a load before it is properly supported by appropri-
ate  mechanical means. Never rely on hydraulic
pressure alone to support load.

• All personnel must be clear before lowering.
• Never try to disassemble a hydraulic cylinder,

Refer repairs to qualified, authorized personnel.

IMPORTANT

• Keep ram clean at all times.
• When the ram is not in use, keep the piston(s)

fully retracted.

• Use an approved, high-grade pipe thread sealant

to seal all hydraulic connections. Teflon tape can
be used if only one layer of tape is used and it is
applied  carefully (two threads back) to prevent the
tape from being introduced into hydraulic system.
A piece of tape could travel through the system
and obstruct the flow of fluid and adversely affect
function.

• Never attach  ANY component not authorized by

Sears.

KNOW YOUR SYSTEM

Your ram, hose(s), couplings and pump all must be
rated for the same maximum operating pressure,
correctly connected and compatible with the
hydraulic fluid used. An improperly matched system
can cause the system to fail and possibly cause
serious injury. If you are in doubt, consult Sears.

!

Center loads on ram

!

WARNING

!

WARNING

SAFETY INSTRUCTIONS (cont.)

© Sears, Roebuck and Co.

Содержание 50347

Страница 1: ...y Operation Maintenance Parts CAUTION Before using this product read this manual and follow all its Safety Rules and Operating Instructions ATENCIÓN Leer comprender y seguir las instrucciónes antes de utilizar el aparato El manual de instrucciónes y la información de seguridad deben estar comunicado en lengua del operador antes del uso No seguir estas indicaciónes puede causar daños personales o m...

Страница 2: ...s product is authorized Make certain that the operator thoroughly understands the inherent dangers associated with the use and misuse of the product If any doubt exists as to the safe and proper use of this product as outlined in this manual remove from service immediately Inspect before each use Do not use if broken bent cracked or otherwise damaged parts are noted If any component of this produc...

Страница 3: ...ctions provided with and on this device before use 2 Inspect before each use Do not use if bent broken leaking or damaged components are noted 3 Ensure that product and application are compatible 4 Check to ensure that all parts of your kit are included see illustration and parts list 5 Carefully remove the dust covers and plugs from hose coupler and ram coupler 6 Connect hose coupler to ram coupl...

Страница 4: ...served to help prevent personal injury Do not exceed rated capacity Use only on hard level surfaces capable of sustaining rated capacity loads Do not open oil filler screw unless ram is fully retracted Wear protective clothing and safety goggles to reduce the risk of injection Do not wear sandals and jewelry when operating this equipment Do not use as a vehicle lifting device or as a vehicle suppo...

Страница 5: ...ch points or crush points that can be created by the load or parts of ram To help prevent material fatigue if the ram is to be used in a continuous application the load should not exceed 85 of the rated capacity Ram must be on a stable base which is able to support the load while pushing or lifting Ensure ram is fully engaged into onto adapters extension accessories To help prevent personal injury...

Страница 6: ...ause failure of the pump and the potential for sudden and immediate loss of load Adding oil 1 With ram fully lowered set pump unit in its normal level position Locate and remove oil filler screw see Figure 1 2 Fill until oil is within 3 8 6 mm of the hole opening reinstall oil filler screw Changing oil For best performance and increased system life replace the complete fluid supply at least once p...

Страница 7: ...ure release valve tightly closed Remedy overload condition Ensure release valve tightly closed Replace ram and or pump Ensure proper fluid level Ensure proper fluid level With ram fully retracted remove oil filler screw to let pressurized air escape then reinstall oil filler screw Poor performance Ram will not lower after unloading Reservoir overfilled Ram damaged Drain fluid to proper level Repla...

Страница 8: ...040 40002 000 Combination Head 1 14 F040 42000 000 Hydraulic Spreader 1000 lb capacity 1 15 F040 20012 000 Dust Cover Hose 1 16 F040 34000 000 Dust Cover Ram 1 17 F040 22201 000 Hose Coupler Male 1 18 F040 90009 K02 Ram Coupler Assy Female 1 19 F040 30000 000 Ram Assembly 1 20 F040 21000 000 Release Valve Knob 1 21 F040 90009 K03 Pump Handle 1 22 F040 22000 000 Hose Assembly with coupler 1 23 F040...

Страница 9: ...Sears Roebuck and Co Hoffman Estates IL 60179 Visit our Craftsman website www sears com craftsman ...

Страница 10: ...ars PartsDirectSM 1 800 366 PART 6 a m 11 p m CST 7 days a week 1 800 366 7278 U S A only www sears com partsdirect To purchase or inquire about a Sears Service Agreement or Sears Maintenance Agreement 1 800 827 6655 U S A 1 800 361 6665 Canada 7 a m 5 p m CST Mon Sat 9 a m 8 p m EST M F 4 p m Sat Para pedir servicio de reparación a domicilio y para ordenar piezas 1 888 SU HOGARSM 1 888 784 6427 A...