Страница 1: ...Save ThisManual Far FutureReference CRAFTSMAN Professional Model No 390 305001 CRAFTSMAN Professional CRAFTSMAN Professional Model No 390 304790 1 3 HP Model No 390 305790 1 2 HP I RRFTJ MRN SUBMERSIBLE SUMP PUMP Safety Instructions Installation Electrical Maintenance Repair Parts Sears Roebuck and Co Hoffman Estates IL 60179 U S A Form No F642 9812 Rev 3 22 05 ...

Страница 2: ...mps normally give many years of trouble free service when correctly installed maintained and used However unusual circumstances interruption of power to the pump dirt debris in the sump flooding that ex ceeds the pump s opacity electrical or mechanical failure in the pump etc may prevent your pump from functioning normally To prevent possible water damage due to flooding consult your local Sears s...

Страница 3: ...This pump is supplied with a grounding conductor and grounding type attachment plug Be certain that it is connected only to a properly grounded ground ing type receptacle Where a 2 prong wall receptacle is encountered it must be replaced with a properly grounded 3 prong receptacle installed in accordance with the National Electrical Code and local codes and ordinances 15 Protect electrical cord fr...

Страница 4: ...ct the pump and switch from the electrical power source before doing any maintenance Follow instructions below to install pump with factory mounted switch 1 Be sure automatic float can swing freely through its entire arc without interference from pump piping sump wall or any other object 2 Plug the automatic switch cord into a properly grounded outlet see Electrical Connections Page 4 Plug the pum...

Страница 5: ...jured and the pump damaged if it starts when you are working on it DO NOT attempt to repair a non operational surnp pump Take it to Sears for service by a qualified technician Generator Sizing Below is the minimum Engine Generator Watt rating required to power this pump motor Any additional loads such as lights must be added to the listed load and the generator sized ac cordingly Generators are av...

Страница 6: ...ge it c Be sure vertical distance from pump discharge outlet to discharge pipe outlet does not exceed maximum vertical pumping distance shown in Specifications below d Be sure discharge pipe is not plugged or frozen TEATHERED SWITCH REPLACEMENT NOTICE Teathered float must be able to swing through its complete arc without interference from sidewall of sump plumbing or any other object 1 Remove pump...

Страница 7: ...re pin holds float rod in switch CAUTION housing otherwise pump will not shut off To check switch operation run pump through one com plete cycle after installation A WARNINGj Risk of electrical shock Can burn or kilL Plug puLmp and switch into a grounded electrical outlet only 7 ...

Страница 8: ...ute 15 Cap Screws 16 Cap Screw 1 1 4x1 1 2 Reducer Bushing 390 305001 PS117 144P U30 955PS CC0030 13 PS117 54 TSU 390 304790 PS17 85 PS19 20SS U30 955PS 2 Req PS28 17 PS28 18 PS19 21 RP0005248 U30o539SS PW117 281 TSU PS17 46P 390 305790 PS17 85 PS19 20SS U30 955PS 2 Req PS28 17 PS28_18 PS19 21 RP0005248 U30 539SS PW117 237 TSU PS17 46P PS1 28P U30 920SS 3 Rap PS5 22P PS20 19 PS3 29P U30 934ZP 8 Re...

Страница 9: ...9 ...

Страница 10: ...ment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytime day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparaci6n a domicilio y para ordenar piezas 1 888 SU HOGAR _ 1 8...