• Plug a 2-strand wire connector into
each unit as shown in Figure 6. Insert
the connector and push until you
hear a click. The white tab on the
sensor should be flush with the back
of the connector.
• Run wires from both sensors to the opener as shown
in Figure 7. Use insulated stapies to secure the wire
to the wall and ceiling.
• Connect both sets of wires to the opener terminals by
color, white/black to black and white to white.
• Plug in the opener. Make sure the Lock Feature is
off. Green indicator lights in both the sending and
receiving eyes will
glow if wiring connections and
aiignment are correct.
If the indicator light is
off in the receiving eye
(and
the invisible light beam path is not obstructed),
alignment is required.
• Loosen the receiving eye wing nut to allow slight
rotation of unit. Adjust sensor vertically and
horizontally until the green indicator light
glows.
• When indicator lights are glowing in both units,
tighten the wing nut in the receiving eye unit.
Trouble Shooting
1. If the
sending eye
indicator light does not glow
after installation, check for:
• Electric power to the opener.
• A short in the black/white wires. These can occur
under staples or at screw temminal connections.
• Incorrect wiring between sensors and opener.
• An open wire, (wire break3.
2. If the sending eye indicator light glows but the
receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.
23