page 8

10. Testing Your Fan.

9. Switch Housing Assembly. 

diagram 2

diagram 3

diagram 4

diagram 1

Remove 3 screws from outer edge of switch housing 
plate (

save screws for later use

). 

Remove 1 screw from fitter plate on underside of motor 
and partially loosen the other 2 screws. Align slotted 
holes in center of switch housing plate with loosened 
screws in fitter plate, allowing male plug from motor 
housing to come through hole in middle of switch 
housing plate. Twist switch housing plate to lock. 
Re-insert screw that was removed and secure all screws. 

Connect male plug from motor housing to female plug 
from switch housing. Make sure plugs connect tightly. 

Align holes in switch housing with holes in switch 
housing plate. Re-insert screws that were previously 
removed and use a Phillips screwdriver to secure all 
screws.  

switch housing

plate

switch housing

male plug

female plug

fitter

 plate

motor housing

It is recommended that you test fan before 
finalizing installation. Restore power from circuit 
box and wall switch (if applicable). Test fan speeds 
with pull chain. Start at the OFF position (no blade 
movement). First pull will set the fan to HI. Second 
pull will set the fan to MEDIUM. Third pull will set 
the fan to LOW. Fourth pull will re-set the fan to 
OFF setting. (

diagram 1

) If fan does not function, 

please refer to "Troubleshooting" section to solve 
any issues before contacting Customer Service.

Turn fan completely off 

before

 moving the reverse 

switch (located on switch housing). Set reverse 
switch to recirculate air depending on the season:
 

- LEFT position in summer (

diagram 2

)

 

- RIGHT position in winter (

diagram 3

)

A ceiling fan will allow you to raise your thermostat 
setting in summer and lower your thermostat 
setting in winter without feeling a difference in 
your comfort.

Important

: Reverse switch must be set either 

completely to the LEFT

 or 

completely to the RIGHT

 for 

fan to function. If the reverse switch is set in the 

middle

 position (

diagram 4

), fan will not operate.

Attach pull chain extension supplied or custom 
pull chain extension (sold separately) to end of the 
pull chain. 

switch housing

pull chain

extension

reverse 
switch

motor housing

Содержание RU72AG5

Страница 1: ...pg 6 Canopy Assembly pg 7 Blade Assembly pg 7 Switch Housing Assembly pg 8 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 PRINTED IN CHINA READ THESE INSTRUCTIONS AND...

Страница 2: ...rger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for r...

Страница 3: ...t all parts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c 6in downrod and hanging ball 1 piece d motor housing 1 piece e switch housing plate 1 piece f blade arm 5...

Страница 4: ...cket to outlet box using original screws spring washers and flat washers provided with new or original outlet box If installing on a vaulted ceiling face opening of hanging bracket towards high point...

Страница 5: ...her when threading them through the downrod Locate canopy cover in hardware pack Loosen yoke set screws and nuts at top of motor housing Remove pin and clip from motor housing yoke Slide downrod throu...

Страница 6: ...g bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or death Tip Seek the help of another person to hold the stepladder in place and to...

Страница 7: ...om ceiling with wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from cei...

Страница 8: ...s blade arm screws Time Saver Washers for blade screws can be set on each blade screw prior to installing blades Locate 15 blade attachment screws and washers in hardware pack Hold blade arm up to bla...

Страница 9: ...store power from circuit box and wall switch if applicable Test fan speeds with pull chain Start at the OFF position no blade movement First pull will set the fan to HI Second pull will set the fan to...

Страница 10: ...chaser if the fan motor fails to operate satisfactorily when failure results from normal use Parts used in the repair will be billed to the purchaser at prevailing prices at time of repair The purchas...

Страница 11: ...dor P gs 4 5 Instalaci n el ctrica P g 6 Colocaci n de la cubierta decorativa P g 7 Colocaci n de las aspas P g 7 Instalaci n de la caja de encendido P g 8 Verificaci n del funcionamiento del ventilad...

Страница 12: ...del cable de la casa es superior al 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informars...

Страница 13: ...rativa en paquete de art culos de ferreter a 1 unidad l paquetes de art culos de ferreter a p gina 2 Abrir el empaque cuidadosamente Sacar los art culos del embalaje Sacar el motor y ponerlo en una al...

Страница 14: ...io puede resultar en lesiones graves PRECAUCION Asegurarse de que la caja de salida est conectada a tierra correctamente y que haya un conductor a tierra cable VERDE o pelado Instalar el soporte de mo...

Страница 15: ...e art culos de ferreter a Aflojar los tornillos de fijaci n del cuello y las tuercas en el cuello del bastidor del motor Quitar el perno y la clavija del cuello del bastidor del motor Pasar el tubo po...

Страница 16: ...porte de montaje ADVERTENCIA El no alinear la ranura en la bola que sirve para colgar con la parte saliente del soporte de montaje puede causar lesiones graves o la muerte Sugerencia Solicitar ayuda d...

Страница 17: ...or al cable NEGRO del techo con un conector para cable provisto Conectar el cable BLANCO del ventilador al cable BLANCO del techo con un conector para cable provisto Conectar todos los conductores a T...

Страница 18: ...cubierta decorativa Para ahorrar tiempo Se pueden poner las arandelas en los tornillos que son para las aspas antes de colocar las aspas Localizar 15 tornillos y arrandelas para fijar las aspas en uno...

Страница 19: ...pletamente hacia IZQUIERDA o completamente hacia DERECHA para que funcione el ventilador Si el interruptor de reversa est puesto en la posici n de en medio diagrama 4 no funcionar el ventilador Fijar...

Страница 20: ...r del ventilador no funciona satisfactoriamente a causa del uso normal Las piezas que se utilizan en hacer la reparaci n ser n facturadas al comprador a los precios prevalecientes en el momento de la...

Отзывы: