11. Remote Control Operation.

page 6

7. Canopy Assembly.

canopy

hanging bracket

screw

6. Wiring. (cont.)

antenna

receiver

IN ORDER TO WIRE WALL CONTROL

, remove existing wall switch. Wire 

the

 WALL CONTROL

 with wire connectors provided as shown in 

diagram at right.

* Wrap each wire connector separately with electrical tape as an extra 
safety measure. Gently push taped wire connectors into outlet box.

Use a ballpoint pen or a small screwdriver to set the code switches 
1 through 4 on the wall control. Factory setting is pre-set and not 
recommended for use. 

Write down number sequence for use in Section 9. 

[

Note

: Since this fan comes without a light kit, set the dimmer switch 

(labeled "D" and "X") in the "OFF" position (X).]

Attach wall control to outlet box and secure with screws from original 
wall switch. Attach front plate to wall control using 2 screws provided 
in the wall control.

8. Blade Assembly.

motor
housing

fan

motor

blade

blade arm

plastic
motor
lock

lock washer

blade arm screw

blade attachment

screws and washers

black (OUT to fan)

green

black

(AC IN from

breaker box)

black

(TO POWER supply)

(wiring for wall control)

black

green/

green/

bare 

bare 

 ground

 ground

green/

bare 

 ground

outlet box

control

plate

1

2

3
4
X

D

Locate 2 screws on underside of hanging bracket 
and remove screw closest to the open end of of the 
hanging bracket. Partially loosen the other screw. Lift 
canopy to hanging bracket. Place rounded part of 
slotted hole in canopy over loosened screw in 
hanging bracket and push up. Twist canopy to lock. 
Re-insert screw that was removed, and then tighten 
both screws securely.

*Remember that antenna for remote control receiver 
must rest 

outside

 of hanging bracket.

code
switches

Time Saver: 

Washers for blade screws can be set 

on each blade screw prior to installing blades.

Locate 20 blade attachment screws and washers 
in hardware pack. Hold blade arm up to blade and 
align holes. Insert 4 blade attachment screws 
(along with washers) with fingers first and then 
tighten screws securely with Phillips screwdriver. 
Repeat procedure for the remaining blades.

Remove blade arm screws and lock washers  from 
underside of motor. If plastic motor locks are 
installed with blade arm screws, discard plastic 
motor locks (

save blade arm screws and lock 

washers to secure blade arms

).

 

Align blade arm 

holes with motor screw holes and attach blade 
arm with lock washers and blade arm screws. 
Before securing screws permanently, repeat 
procedure with remaining blade arms. Securely 
tighten all screws.

Note

: Tighten blade arm screws twice a year.

Содержание ELLINGTON PAP52ABZ5RCDI

Страница 1: ...6 Blade Assembly pg 6 Automated Learning Process Activating Code 7 Wall Control Operation pg 7 Remote Control Operation pg 8 Testing Your Fan pg 8 Troubleshooting pg 9 Warranty pg 9 Parts Replacement pg 9 net weight of fan 31 97 lb 14 5 kg PRINTED IN CHINA Installation Guide For Models PAP52ABZ5RCDI PAP52MWW5RCDI READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE E192641 LISTED For Damp Location...

Страница 2: ...oper size wire connectors to use WARNING If using this fan in a DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of personal injury electrical shock or death 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable for use with the model ...

Страница 3: ... 5 pieces k hardware packs page 2 d j k h e f a b c 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that all parts have been included g i IMPORTANT REMINDER ...

Страница 4: ... box screws flat washers Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and can support ...

Страница 5: ...top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of extended downrod and raise hanging ball Be sure stop pin aligns with slots on the inside of the hanging ball Tighten set screw securely Tip To prepare for threading electrical wires through downrod apply a small piece of electrical tape to the ends of the electrical wi...

Страница 6: ...p each wire connector separately with electrical tape as an extra safety measure Gently insert receiver flat side up into hanging bracket and carefully push taped wire connectors into outlet box Allow antenna from remote control receiver to hang outside of hanging bracket ground green or bare wiring for receiver white supply wire black supply wire black black white blue blue white from receiver bl...

Страница 7: ...ground outlet box control plate 1 2 3 4 X D Locate 2 screws on underside of hanging bracket and remove screw closest to the open end of of the hanging bracket Partially loosen the other screw Lift canopy to hanging bracket Place rounded part of slotted hole in canopy over loosened screw in hanging bracket and push up Twist canopy to lock Re insert screw that was removed and then tighten both screw...

Страница 8: ...or openers car alarms or security systems If you find that your fan goes on and off without using your remote control simply change the combination code in your remote control transmitter and wall control To set the code perform these steps Remove battery cover from back side of transmitter Use a ballpoint pen or a small screwdriver to set the code switches 1 through 4 for the transmitter Use the ...

Страница 9: ...es not operate all of the fan functions refer to Troubleshooting section to solve any issues before contacting Customer Service Turn fan completely off before moving the reverse switch located on top of motor housing Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in winter diagram 3 A ceiling fan will allow you to raise your thermosta...

Страница 10: ...N warrants this fan to the original household purchaser for indoor use under the following provisions 1 YEAR WARRANTY CRAFTMADE ELLINGTON will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Ellington Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade Ellington We will repair o...