Craftmade Bellows II Скачать руководство пользователя страница 4

4. Hanging Bracket Installation.

page 3

ON

OFF

ON

OFF

3. Installation Preparation.

hanging bracket

10 feet

(3.05m) (76cm)

30 

inches

12f

t.

  - 20f

t.

12ft. - 20ft.

(3.66m - 6.1m)

(3.66m - 6.1m)

blade edge

Turn off circuit breakers to current fixture from 
breaker panel and be sure operating light switch is 
turned to the OFF position. 

WARNING: 

Failure to disconnect power supply prior 

to installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be 

sure the outlet box is securely attached to the building 
structure and can support the full weight of the fan. 
Ensure outlet box is clearly marked "Suitable for Fan 
Support." If not, it must be replaced with an approved 
outlet box. Failure to do so can result in serious injury.

CAUTION

Be sure outlet box is grounded properly 

and that a ground wire (

GREEN

 or bare) is present.

Install hanging bracket to outlet box using original 
screws, spring washers and flat washers provided 
with new or original outlet box.

Arrange electrical 

wiring around the back of the hanging bracket and 
away from the hanging bracket opening.

*Note

: It is very important that you use the proper 

hardware when installing the hanging bracket as this 
will support the fan. 

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 10 feet (3.05m) from the floor and 
30in. (76 cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 
400 square feet (37.2 square meters).

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape

spring washers

outlet box screws

flat washers

This fan can be mounted with a 

downrod 

on a 

regular (no-slope) ceiling 

only

. Fan 

CANNOT

 

mount as a flushmount installation 

nor

 on a 

vaulted ceiling.

downrod

installation

CANNOT be
installed on
angled or
vaulted ceilings

flushmount

installation

Содержание Bellows II

Страница 1: ...stallation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pgs 5 6 Canopy Assembly pg 6 Light Kit Assembly Optional pg 7 Alternate Final Assembly Without Light Kit pg 8 Assembly of Handheld Remote Control pgs 8 9 Automated Learning Process Activating Code pg 9 Remote Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacement...

Страница 2: ... The wires should be spread apart with the grounded conductor and the equipment grounding conductor on opposite sides of the outlet box WARNING To reduce the risk of electrical shock or fire do not use this fan with any solid state speed control device or control fan speed with a full range dimmer switch Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan...

Страница 3: ...re attached to light kit fitter 1 piece q finial pre attached to light kit fitter 1 piece r motor assembly 1 piece s hardware packs 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor assembly and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check ...

Страница 4: ...anging bracket to outlet box using original screws spring washers and flat washers provided with new or original outlet box Arrange electrical wiring around the back of the hanging bracket and away from the hanging bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan To prevent personal injury and damage ensure ...

Страница 5: ...wnrod Refer to diagram 2 Thread downrod into the motor assembly yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nuts securely Refer to diagram 2 Locate canopy cover in a hardware pack Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note C...

Страница 6: ...safety cable slips the loop must be adjusted tighter Extra cable slack can be left in ceiling area motor assembly 6 Wiring CAUTION Be sure outlet box is properly grounded and that a ground wire GREEN or Bare is present Make sure all electrical connections comply with Local Codes or Ordinances and the National Electrical Code or Canadian Electrical Code If you are unfamiliar with electrical wiring ...

Страница 7: ...all control Attach wall control to outlet box and secure with screws from original wall switch Attach wall plate included to wall control using 2 screws provided with the wall control wiring for wall control black OUT to fan green black AC IN from breaker box black TO POWER supply black green green bare bare ground ground green bare ground outlet box wall control face plate 12V battery dimmer swit...

Страница 8: ...curely Align slotted holes in light kit fitter with loosened screws in large fitter plate Twist light kit fitter to lock Re insert screw that was previously removed Tighten all 3 screws securely Install 2 medium base 9 watt LED bulbs included Important When replacing bulbs please allow bulbs and glass shade to cool down before touching large fitter plate light kit fitter molex connections bulb mot...

Страница 9: ...r edge of small fitter plate Align holes in metal cover with holes in outer edge of small fitter plate Secure metal cover with 3 screws that were just removed IN ORDERTO USETHE HANDHELD REMOTE CONTROL PLEASE CONTINUE WITH SECTION 10 for remote control assembly instructions If you have already installed the wall control but do not wish to use the handheld remote control please proceed to Section 11...

Страница 10: ...ds page 9 dimmer switch wall control wire wire wire 12V battery 10 Assembly of Handheld Remote Control cont wall control face plate remote control cover BOTTOM post hole diagram 2 diagram 3 post hole remote control cover TOP DIM ON 1 1 2 2 DIM ON 1 1 2 2 CAUTION The wall and or handheld remote control can be programmed to multiple receivers or fans If this is not desired turn wall switch off to an...

Страница 11: ...section to solve any issues before contacting Customer Service The tilt angle of the smaller fans may be adjusted up or down by simply moving them gently up or down WARNING To avoid personal injury or damage to the fan both the main fan and the smaller fans MUST BE TURNED OFF before adjusting the tilt angle of the smaller fans up or down Fan must be on LOW before setting the fan to reverse directi...

Страница 12: ...WARNING Failure to disconnect power supply prior to troubleshooting any wiring issues may result in serious injury PWLI1903 For parts and information please refer to Parts Inventory on page 2 Craftmade Customer Support 1 800 486 4892 www craftmade com CRAFTMADE LIFETIME LIMITED WARRANTY CRAFTMADE warrants this fan to the original household purchaser for indoor use under the following provisions 1 ...

Страница 13: ...entilador Págs 4 5 Instalación eléctrica Págs 5 6 Colocación de la cubierta decorativa Pág 6 Instalación del juego de luz opcional Pág 7 Instalación final alternativa sin el juego de luz Pág 8 Ensamblaje del control remoto de mano Págs 8 9 Proceso de aprendizaje automático Activar el código Pág 9 Funcionamiento del control remoto Pág 10 Verificación del funcionamiento del ventilador Pág 10 Localiz...

Страница 14: ...as conexiones estén totalmente seguras 7 Después de haber terminado todas las conexiones eléctricas los conductores empalmados deben ser volteados para arriba y colocados cuidadosamente dentro de la caja de salida Los alambres se deben de separar con el conductor a tierra a un lado y el conductor a tierra del equipo al lado opuesto ADVERTENCIA para reducir el riesgo de incendio o un choque eléctri...

Страница 15: ...ectador para el juego de luz 1 unidad q adorno con rosca fijado al conectador para el juego de luz 1 unidad r unidad del motor 1 unidad s paquetes de artículos de ferretería 1 Desempaquetado del ventilador Abrir el empaque cuidadosamente Sacar los artículos del embalaje Sacar la unidad del motor y ponerla en una alfombra o en el embalaje para evitar rayar el acabado Guardar la caja de cartón o el ...

Страница 16: ...plen corriente a la caja de salida y asegurarse de que el interruptor de luz esté APAGADO ADVERTENCIA no desconectar el suministro de fuerza antes de la instalación puede tener por resultado lesiones graves Quitar el aparato existente ADVERTENCIA si utiliza una caja de salida existente asegurarse de que la caja de salida esté firmemente conectada a la estructura del edificio y que sea capaz de sos...

Страница 17: ... uno de los paquetes de artículos de ferretería Deslizar la cubierta del cuello la tapa de la cubierta decorativa y la cubierta decorativa por el tubo Referirse al diagrama 3 Nota se debe voltear la tapa de la cubierta decorativa para que el lado brillante dé a la unidad del motor Pasar el cable de seguridad y los cables por la bola que sirve para colgar y luego deslizar la bola que sirve para col...

Страница 18: ...puede poner el cable en exceso en el área del techo 6 Instalación eléctrica PRECAUCIÓN asegurarse de que la caja de salida esté conectada a tierra como es debido y que exista un conductor a tierra VERDE o pelado Asegurarse de que todas las conexiones eléctricas cumplan con los Códigos o las Ordenanzas Locales y el Código Nacional Eléctrico Si usted no está familiarizado con el alambrado eléctrico ...

Страница 19: ...nterruptor a la posición ENCENDIDO DIM Escoger una tapa color almendra o blanca y apretarla firmemente en la parte delantera del control de pared Sujetar el control de pared a la caja de salida y asegurarlo con los tornillos del interruptor de pared original Sujetar la tapa de tomacorriente incluida al control de pared usando los 2 tornillos provistos con el control de pared DIM ON 1 1 2 2 7 Coloc...

Страница 20: ...un clic Alinear los agujeros con ranura en el conectador para el juego de luz con los tornillos aflojados en la placa de conexión grande Girar el conectador para el juego de luz para cerrarlo Volver a introducir el tornillo que se quitó anteriormente Apretar bien los 3 tornillos Instalar 2 bombillas LED de base mediana de 9 vatios incluidas Importante Cuando necesite reemplazar las bombillas dejar...

Страница 21: ...terior de la placa de conexión pequeña Alinear los agujeros de la cubierta de metal con los agujeros en el borde de la placa de conexión pequeña Asegurar la cubierta de metal con los 3 tornillos que apenas se quitaron placa del motor placa de conexión pequeña cubierta de metal unidad del motor conexiones molex placa de conexión pequeña unidad del motor 10 Ensamblaje del control remoto de mano PARA...

Страница 22: ...ilizar el control remoto por un tiempo extendido diagrama 2 interruptor del reductor de luz control de pared cable cable cable batería de 12V control de pared tapa cubierta del control remoto parte INFERIOR poste agujero agujero para el poste cubierta del control remoto parte SUPERIOR DIM ON 1 1 2 2 DIM ON 1 1 2 2 diagrama 3 PRECAUCIÓN se puede programar el control de pared control remoto de mano ...

Страница 23: ...para resolver cualquier asunto antes de comunicarse con el Servicio al cliente Se puede ajustar el ángulo de inclinación de los ventiladores más pequeños hacia arriba o hacia abajo simplemente moviéndolos cuidadosamente hacia arriba o hacia abajo ADVERTENCIA para reducir el riesgo de daño corporal o algún daño al ventilador el ventilador principal y los ventiladores más pequeños DEBEN ESTAR APAGAD...

Страница 24: ... tornillo de fijación en la bola que sirve para colgar Localización de fallas ADVERTENCIA no desconectar el suministro de fuerza eléctrica antes de hacer localización de fallas para cualquier problema de instalación eléctrica puede causar lesiones graves Garantía PWLI1903 Piezas de repuesto Para piezas o información referirse al Inventario de piezas en la página 2 Servicio al cliente de Craftmade ...

Отзывы: