Craftmade Accolade TH011 Скачать руководство пользователя страница 3

XII I II

IIIIV

VVI

VIIVII

IIX

X X

I

Fixture Head Brackets

TH011 Thermometer/Clock Assembly

Assembly:

1)   Attach fixture arm to wall mounting bracket by aligning holes and securing with three 

allen screws.

2)   Position bracket to desired location on wall and mark spots on wall where the four 

holes are located.

3)   For assembly on concrete or cement wall, drill (D7mm X L30mm) size holes on wall 

where you have marked the spots.

4)   Insert plastic anchors into holes, ensuring each anchor is securely embedded into the 

wall.

5)   For assembly on wood surfaces, drill wall mount screw directly into wood surface, 

while screwing backplate and arm to wall.

6)   Attach fixture head to wall mount bracket by fitting fixture head brackets over fixture 

arm and aligning holes together. Secure with the two machine thread screws.

Warning: 

The mounting of this fixture must be secured directly to a wood stud or directly into cement 
or concrete wall.

TEMPERATURE

F

C

-10

-10

0

10

20

30

40

50

-20

20

0

40

60

80

100

HUMIDITY

%

90

80

70

60

50

40

30

20

10

0

BARO

10

6

105

10

4

103

102

101

100

99

98

97

96

31

30

K   P

   A

120

29

Inc

hH

g

Plastic

Anchor

4 Pcs

Wall Mounting Screw 4 Pcs

Machine

Thread

2 Pcs

Key

2 Pcs

Double Sided Head 1 Pc

PARTS:

Step 1

Wood or

Concrete Wall

Plastic Anchor

Wall Mounting Screw

Fixture Arm

Replacing Batteries: Installed On Side of 

Housing

  

Look for curled tab on side of housing. Pull 

and slide tab downward to access battery 

casing. Insert batteries matching the “-” and 

“+” markings, as indicated on the inside of 

the battery housing, to the markings located 

on the battery. Replace battery cover by 

sliding cover into place.

Step 2

Step 3

E3

E4

Fixture Arm 1 Pc

Step 1

Step 2

Wall Mounting Bracket

Fixture Arm

Machine Thread Screw

Wall Mounting 

Bracket 1 Pc

Allen Screw 3 Pc

Allen Wrench 1 Pc

Содержание Accolade TH011

Страница 1: ...e com www craftmade com Impreso en China P O Box 1037 650 S Royal Lane Suite 100 Coppell TX 75019 EE UU 800 486 4892 de 8 heures 17 heures Heure standard du centre Num ro de t l copieur gratuit 877 30...

Страница 2: ...of xture housing labeled Clock b To adjust the time reading softly push key inwards and turn to adjust needle on the units face 2 Barometer gauge adjustment a Insert key into adjustment hole on bottom...

Страница 3: ...hine thread screws Warning The mounting of this xture must be secured directly to a wood stud or directly into cement or concrete wall TEMPERATURE F C 10 10 0 10 20 30 40 50 20 20 0 40 60 80 100 HUMID...

Страница 4: ...ck horloge b Pour mettre l horloge l heure enfoncer la cl doucement et la tourner adin de r gler l aiguille du cadran de l horloge 2 R glage du barom tre a Introduire la cl dans le trou de r glage qui...

Страница 5: ...ignant les trous L assujettir au moyen des deux vis m taux Avertissement Cet appareil doit tre mont directement sur un montant en bois ou dans un mur en ciment ou en b ton tape 1 Remplacement des pile...

Страница 6: ...ente hacia adentro y g rela para ajustar la manecilla en la car tula de la unidad 2 Ajuste de los indicadores del bar metro a Introduzca la llave en el ori cio de ajuste ubicado en el lado inferior de...

Страница 7: ...ncima del brazo de ella y alineando los agujeros entre s Fije con los dos tornillos enroscados a m quina Advertencia El montaje de esta instalaci n debe jarse directamente a un perno de madera o bien...

Отзывы: