OPERATION
Press the lighted push button to open or close the door.
Press again to
reverse
the door during the closing cycle
or to
stop
the door while it's opening.
Light Feature
– Press the Light button to turn the opener
light on or off. It will not control the opener lights when the
door is in motion. If you turn it on and then activate the
opener, the light will remain on for 4-1/2 minutes. Press
again to turn it off sooner.
Lock Feature
– Designed to prevent operation of the
door from hand-held remote controls. However, the
door will open and close from the Door Control, the
Outdoor Key Switch and the Keyless Entry
Accessories.
To activate
– press and hold the Lock button for 2
seconds. The push button light will flash as long as the
Lock feature is on.
To turn off
– press and hold the Lock button again for
2 seconds. The push button light will stop flashing. The
Lock feature will also turn off whenever the “learn” button
on the motor unit panel is activated.
Model 139.53687
Premium Control Console
114A2349B
Locate the door control within sight of the door at a minimum
height of 5 feet (1.52 m) where small children cannot reach, and
away from all moving parts of the door and door hardware.
INSTALLATION
Remove the old Control Panel/Lighted Door Control Button.
The door control is typically attached directly to the wall. If
installing into drywall, drill 5/32" holes and use the anchors
provided.
For pre-wired installations (as in new home
construction), Console models may be mounted to a standard
single gang box (Figure 2).
1. Strip 1/4" (6 mm) of insulation from one end of the bell wire
and connect it to the two screw terminals on the back of the
door control: white to 2, and white/red to 1.
2. Remove white cover by gently prying at slot in top of the cover
with a small flat head screwdriver. Fasten with 6ABx1-1/4"
self-tapping screws (drywall installation) or 6-32x1" machine
screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to protrude above
wall surface.
• Position bottom of door control on screw head and slide
down to secure. Adjust screw for snug fit.
• Drill and install top screw with care to avoid cracking plastic
housing.
Do not overtighten.
• Insert top tabs and snap on cover.
3.
(For standard installation only)
Run the bell wire up the wall
and across the ceiling to the motor unit. Use insulated staples
to secure the wire in several places. Do not to pierce the wire
with a staple, creating a short.
4. Connect the bell wire to the terminal screws on the opener
panel: white to 2; white/red to 1.
5. Position the antenna wire as shown.
T
o prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is not connected BEFORE installing door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach of
children at a minimum height of 5 feet (1.52 m), and away from all
moving parts of door.
• NEVER permit children to operate or play with door control push
buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly adjusted,
and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed. NEVER
permit anyone to cross path of closing garage door.
WARNING
CAUTION
WARNING
WARNING
USER INSTRUCTIONS
© 2006, Sears, Roebuck and Co., ® Registered Trademark / ™ Trademark /
SM
Service Mark of Sears, Roebuck and Co.
® Marca Registrada / ™Marca de Fábrica /
SM
Marca de Servicio de Sears, Roebuck and Co.
®
To Replace,
Insert
Top Tabs
First
To Remove,
Twist
Here
REMOVE & REPLACE COVER
LOCK
LIG
HT
PRE-WIRED
INSTALLATION
24 Volt
2-Conductor
Bell Wire
Light
Antenna
Back Panel
of Opener
Opener
Terminal Screws
KG
KG
1
3
9
7
5
1
3
9
7
5
2
3
1
LOCK
L G
I HT
2-Conductor
Bell Wire
Lock
Lighted
Push Button
PREMIUM CONTROL CONSOLE
Terminal
Screws
Top
Mounting
Hole
Bottom
Mounting
Hole
BACK VIEW
WHITE
2
RED
1
Figure 1
Figure 2