Super Shot 125 Diesel Melter Part Manual
Chapter 8 Troubleshooting (43600, 43800 and 45500)
©2017 by Crafco, Inc. All Rights Reserved………………...……………Troubleshooting (43600, 43800, and 45500) 8-1
8.0 Troubleshooting (43600, 43800 and 45500)
8.1 Diesel Burner Troubleshooting
Symptoms: Burner will Not Ignite
8.1.1
Step
Possible Cause
If . . .
1
Start Troubleshooting at the control box. Is
the Isuzu engine running?
•
Yes, go to Step 2.
•
No, start the Isuzu engine.
•
Note
:
You can troubleshoot the burner
without the engine running, but you must
connect a battery charger to the battery and
the ignition must be in the “ON” position.
2
Is the “POWER” toggle switch in the “ON”
position?
•
Yes, go to Step 3.
•
No, turn the toggle switch to the “ON”
position.
3
Are both the Material and Hot Oil
temperature dials set to proper operating
temperatures?
•
Yes, go to Step 4.
•
No, set the Material according to the type of
sealant you are using and the Hot Oil 100°F
above the Material set point.
4
Are both the Material and Hot Oil
temperature displays reading a three digit
positive number?
•
Yes, go to Step 5.
, Step 2a.
5
Is the red "Burner" light "ON"?
•
Yes, go to Step 6.
•
, Step 4.
6
Is the diesel tank full?
•
Yes, go to Step 7.
•
No, fill your tank or make sure you have
enough fuel for the day.
7
Did you run the diesel tank low on fuel or
empty?
•
Yes, you need to bleed your burner, go to
Table 8-12 Bleeding the Diesel Burner
•
No, go to Step 8.
Table 8-1 Basic Visual Troubleshooting
Содержание SUPER SHOT 125
Страница 1: ...Parts Manual 26631 Revision D SUPER SHOT 125 DIESEL MELTER ALL MODELS...
Страница 4: ...Super Shot 125 Diesel Melter PN 43600 Super Shot 125 Diesel Melter with Compressor 100 CFM PN 47400...
Страница 20: ......
Страница 24: ......
Страница 28: ......
Страница 64: ......
Страница 68: ......
Страница 224: ......
Страница 228: ......
Страница 229: ......
Страница 230: ...2017 Crafco Inc...