GENERAL SAFETY INSTRUCTIONS

Please read, follow and understand the contents of this entire manual, with special 

attention given to Danger, Warning and Caution statements. 

FOR USE BY PROFESSIONALLY TRAINED AND CERTIFIED OPERATORS ONLY. 

MOST STATES, COUNTRIES, ETC., MAY REQUIRE USER TO BE LICENSED. 

PLEASE CHECK WITH YOUR LOCAL GOVERNMENT AGENCY.

DANGER:  

The recovery tank used with this contains liquid refrigerant. Overfilling 

recovery tank may cause a violent rupture resulting in severe injury or even 

death. 

As a minimum, please use a scale to continuously monitor 

recovery tank weight.

DANGER:   EXPLOSION RISK! 

This unit is not certified as ‘explosion proof’ for explosive 

rated environments. It is only to be used in normal environments.

DANGER:

  

ELECTRICAL SHOCK HAZARD: 

Always disconnect power source when 

servicing this equipment.

WARNING:  

Do not use equipment in the vicinity of spilled or open containers of gasoline 

or other flammable substances. 

WARNING:

  All hoses may contain liquid refrigerant under pressure. Contact with 

refrigerant may cause frostbite or other related injuries. Wear proper personal 

protective equipment such as safety goggles and gloves. When disconnecting 

any hose, please use extreme caution.

WARNING: TO REDUCE RISK OF FIRE: 

Avoid use of an extension cord because 

extension cord may overheat. If you must use an extension cord, use 10 awg 

minimum.

WARNING:

  Avoid breathing refrigerant vapors and lubricant vapor or mist. Breathing high 

concentration levels may cause heart arrhythmia, loss of consciousness, or 

even cause suffocation. Exposure may irritate eyes, nose, throat and skin. Please 

read manufacturer’s Material Safety Data Sheet for further safety information on 

refrigerants and lubricants.

WARNING

:  Make certain all safety devices are functioning properly before operating 

equipment.

CAUTION:  

To avoid cross contamination of refrigerant and potential leakage to the 

atmosphere, proper hoses and fittings should be used and checked for 

damage. 

CAUTION:

   To avoid overfilling refrigerant tank, read and follow manufacturer’s 

recommended filling instructions for refrigerant being recovered.

CAUTION:

   This equipment is intended for use of one refrigerant at a time. Mixing of 

different refrigerants will cause your recovered supply of refrigerant to become 

contaminated.  

Note: It is very expensive to destroy mixed or damaged refrigerants.

www.

.com

[email protected]

1.800.561.8187

Содержание Tech-Set TR19 Series

Страница 1: ...EEN VERIFIED BY UNDERWRITERS LABORATORIES INC TO MEET EPA S MINIMUM REQUIREMENTS FOR RECOVERY EQUIPMENT INTENDED FOR USE WITH ALL SYSTEMS CONTAINING REFRIGERANTS FROM ARI740 98 CATEGORIES III IV AND V UL CONTROL NUMBER 2HA5 Evaluated for performance in accordance with Sec 608 of the Clean Air Act Feb 29 1996 using AHRI 740 98 test methods www com information itm com 1 800 561 8187 ...

Страница 2: ...filter Weighs less than 19 lbs Special cooling system design improves compressor longevity Efficient suction and discharge valve design for faster recovery Durable crankshaft design for improved reliability Unique head design for superior performance Patents pending CONTENTS KEY FEATURES Key Features 2 General Safety Instructions 3 Specifications 4 Unit Layout 4 Direct Vapor or Liquid Recovery 5 H...

Страница 3: ...nal protective equipment such as safety goggles and gloves When disconnecting any hose please use extreme caution WARNING TO REDUCE RISK OF FIRE Avoid use of an extension cord because extension cord may overheat If you must use an extension cord use 10 awg minimum WARNING Avoid breathing refrigerant vapors and lubricant vapor or mist Breathing high concentration levels may cause heart arrhythmia l...

Страница 4: ...r Consumption 500 W High Pressure Shut Off 550 psig Auto Reset 550 psig Auto Reset 525 psig 38 bar Manual Reset Refrigerants ARI740 Class III R 12 R 134a R 401C R 406A R 500 R 12 R 134a R 22 R 401A R 401B R 401C R 402A R 402B R 404A R 406A R 407A R 407B R 407C R 407D R 407E R 407F R408A R 409A R 410A R 411A R 411B R 412A R 500 R 502 R 507A R 509A ARI740 Class IV R 22 R 401A B R 402B R 407C D E F R...

Страница 5: ...ted DOT recovery tank vapor valve Note The recovery tank must be rated for 38 bar 550 PSI 2 Open the vapor valve on the DOT recovery tank 3 Keep the manifold valves closed at this time 4 Push the main power switch ON 5 Once unit has started open both HI LO manifold valves to start the refrigerant recovery flow Note The TR19 is designed to directly recover large amounts of liquid refrigerant If dur...

Страница 6: ... vapor and liquid valves on the DOT recovery tank 3 Keep the manifold valves closed at this time 4 Push the main power switch ON 5 Once unit has started open the LO manifold valve on the manifold to start the liquid refrigerant flow to the TR19 Monitor the liquid refrigerant flow in the manifold sight glass Note The TR19 is designed to directly recover large amounts of liquid refrigerant If during...

Страница 7: ...d connect from the TR19 IN port to the DOT recovery tank vapor valve The other spare hose should connect from the TR19 OUT port to the vapor service port on the system being serviced Note The DOT recovery tank must be rated for 38 bar 550 PSI 2 Close the manifold LO side valve Open the manifold HI side valve Open the DOT recovery tank s liquid valve 3 Push the main power switch ON 4 Open the DOT r...

Страница 8: ...ance The TR19 is equipped with a 100 mesh screen filter This filter should be checked periodically A partially clogged filter will slow recovery rate Check filter cartridge as follows 1 Use a 5 8 socket or boxed end wrench to remove IN port as shown in Figure 1 2 Remove suction port filter cartridge as shown in Figure 2 3 Clean cartridge or replace with new cartridge CPS CRXF3 4 Inspect O ring Re ...

Отзывы: