CPS PT200W Скачать руководство пользователя страница 1

USE PT200W WITH CPS Link

™ 

APP 

1. 

To greatly expand the capability of your gauge, pair it with

a mobile device.

2. 

Follow the Quick Start Gauge Setup Steps 1-2 above.

3.

Scan QR code on the front of this guide, or download the free CPS

Link™ app from the App Store ODS) 

devices 

or Google Play (Aneroid devices).

4. 

From MAIN MENU:

a. Choose SETTlNGS to select the Language, Units, Refrigerants and

any other settings you wish to activate. 

b. 

Choose TOOLS to set up Client, Jobs and Tank Tracker

™ 

information.

5. 

You are now ready to wor1<.

6. Manual OFF: From MAIN MENU, select Exit

Auto OFF: 1 

Minutes = Default (if no key pressed, no wireless

connection, gauge not data logging.

QJS 

• 

(�PfWIM"i 

.. 

-0.1 

,,.

Op

,

en 

.. 

=u,u 

-

''" 

_____ 

,..,_ 

_/It!,_ 

-:-

......... , 

... 

,_ 

........ 

Current Conditions Screen 

Settings Screen 

Test Screen 

SPECIFICATIONS 

Operating Pressure Range 

-14.5 PSIG to 750 PSIG 

Pressure Reading Accuracy 

1 % of r/- 0.1 PSIG (0.01 bar) 

Maximum Pressure 

750 PSIG MWP, 3000 PSIG Burst 

Operating Temperature Range 

23'F 

to 

149'F (·S'C to 65'C) 

Temperature Reading Accuracy 

+/- 0.36'F (+/- 0.2

°

C) 

SH, SC And Saturation 

+/- o.5'F (+/- o.3'C) 

Temperature accuracy 

tH&tl.lhlmmT�Pall8 

-40'F to 302'F (·40'C to 150'C) 

Clamp 

Opening: 1-1/8" (28.5mm) 

Cord Length: 6ft (1,82ml 

Storage 

-40 to 185'F (-40

°

C to 85

°

C) 

Temperature Range 

Operating and Storage Humidity 

0-95%, Non-rondensing 

Wireless Range• 

Power: High 

Up to 250 ft. (76 m); Normal 

Up 

to 175 ft. (53 m); 

Low= 

Up to 100 ft. 

(30 

m) 

Power Source 

One 9 volt alkaline battery {ANSI 1604AC- IEC 6lR61) 

Battery Life 

Up to 40 hours continuous use. 

Auto-Off" 

mlnu1es 

default If no key pressed, no 

wireless connection, gauge not logging data. 

Mechanical Connection 

Standard 1/4" female SAE refrigerant hose type 

(stainless steeQ with core depressor 

Warranty 

1 year 

Gauge To Wireless Device 

Pa1ented Wireless CPS Unkn" Technology  (US 

Connection 

Patent No. 9,043,161) 

"Wireless range and auto-off settings can be configured only on the app. 

ADDITIONAL INFORMATION 

#73-133 Rev. A 

041917JC 

cps�

PT200W 

Wireless Pressure Temperature Gauge 

And Mobile App Quick Start Guide 

cps 

CPS Link 

Download 

App 

Now 

--

Patented CJ)S"link"'• Wireless Technology 

 

�  CE 

ICES-003

TO BE OPERATED BY QUALIFIED PERSONNEL ONLY 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176