Auto Tare and Overload Indicator feature:

The unit will tare off any weight less than 220lbs (100kg) while powering up.  If the weight is more than its 
capacity, the unit will display “OL” to indicate OVERLOAD. The “OL” will also display when the GROSS 
weight is more than its capacity.

For example: The unit starts with 200 pounds on its platform-display reads 0; placing 25 pounds 
makes the unit display OL.

Auto Shut Off and Smart Awake features:

Auto Shut Off -

The unit will automatically shut off after 10 minutes if the weight on its platform does not 

change by more than 1oz (30g) in that period of time.

Note: Auto Shut Off is disabled in the RECOVERY and CHARGE modes.

Smart Awake -

When Auto Shut-Off feature is active, the last weight reading is stored in memory. Next

time scale is activated, scale will resume operation at same point as when Shut-Off occured.

CPS Products, Inc.

1010 East 31st Street, Hialeah, Florida 33013, USA

Tel: 305-687-4121, 1-800-277-3808, Fax: 305-687-3743

E-mail: [email protected]   Website: www.cpsproducts.com

CPS Products Canada LTD.

1324 Blundell Road, Mississauga Ontario L4Y 1M5

Tel: 905-615-8620, Fax: 905-615-9745

E-mail: [email protected]

CPS Products N.V 

Krijgsbaan 241, 2070 Zwijndrecht, Belgium

Tel: (323) 281 30 40, Fax: (323) 281 65 83

E-mail: [email protected]

CPS Products Australia PTY. LTD. 

109 Welland Avenue, Welland, South Australia 5007

Tel: +61 8 8340 7055, Fax: +61 8 8340 7033

E-mail: [email protected]

CPS Products Asia 

87 Bukit Timah Road, Unit B2, Singapore 229834

Tel: (65) 63375691, Fax: (65) 63375692

E-mail: [email protected]

#73-220-Rev.F_CC800A_Manual  2/2/15  2:13 PM  Page 5

Содержание PRO-SET CC800A Series

Страница 1: ...ng and Storage Humidity 0 to 95 non condensing Display Resolution oz gm Increments 25 ounces 10 grams Accuracy 0 05 of reading or 25 oz 10 grams whichever is greater Operating Power Source Two 9V alkaline battery ANSI 1604AC IEC 6LR61 Battery Life 30 hours of continuous use Battery Indicator Battery symbol with 3 segment Power Level Bar Graph Maximum Working Pressure 500 PSIG 34 bar Max Operating ...

Страница 2: ...RE Press and hold for 1 second to tare while the unit is in the WEIGHING mode It returns the display to 00 00 in the SETTING mode The TARE key is not active while the unit is in the HOLD mode In the SET mode the TARE key will reset the programmed amount to zero GO HOLD Initiates the CHARGING or RECOVERY modes per the data entered after pushing the SET key The data entered will determine how long t...

Страница 3: ...proceed to either item A or B A When the programmed charge amount is reached the CC800A will sound a continuous beep and the display will show the amount that has been charged sign on the display Set up another charging process by pressing SET RESET twice and follow the instruction in STEP 6 note that the previous setting amount will show B If the refrigerant is no longer being dispensed after 3 m...

Страница 4: ...ank to confirm the total weight of the cylinder does not exceed the maximum allowable amount 10 If during the recovery process the gross weight exceeds the programmed maximum tank weight the solenoid valve will close preventing the additional filling of the refrigerant cylinder Exchange the cylinder with an empty one and proceed back to STEP 4 When CHARGE mode has been completed remove the cylinde...

Страница 5: ...is active the last weight reading is stored in memory Next time scale is activated scale will resume operation at same point as when Shut Off occured CPS Products Inc 1010 East 31st Street Hialeah Florida 33013 USA Tel 305 687 4121 1 800 277 3808 Fax 305 687 3743 E mail info cpsproducts com Website www cpsproducts com CPS Products Canada LTD 1324 Blundell Road Mississauga Ontario L4Y 1M5 Tel 905 6...

Отзывы: