CPS FX3030 Скачать руководство пользователя страница 11

Common Part List

WARRANTY & REPAIR POLICY

CPS warranties the FX Series Refrigerant Management Centers are free of manufacturing defects.  If a component should fail due to 

manufacturing defect during the first year in service, it will be repaired or replaced (at our option) at no charge.  During the second year, parts 

failures caused by defect are covered under warranty.  CPS will replace any failed part at no charge.  Some failed parts must be returned to 

CPS.  Labor time and mileage are not covered during the second year in service.  CPS will cover the compressor for five full years of service, 

limited to the cost of the compressor only.  Failed compressors will require return to CPS.

This product is warranted to be free from defects in workmanship, materials, and components for a period of one year from the date of purchase. 

All parts and labor required to repair defective products covered under the warranty will be at no charge. The following restrictions apply:

The limited warranty applies to the original purchaser only.

The warranty applies to the product is normal usage situations only, as described in the Operating Manual. The product must be serviced

and maintained as specified.

If product fails, it will be repaired or replaced at the option of the manufacturer.

Transportation charges for warranty service will be reimbursed by the factory upon verification of the warranty claim and submission of a

freight bill for normal ground service. Approval from the manufacturer must be obtained prior to shipping to an authorized service center.

Warranty service claims are subject to authorized inspection for product defect(s)

The manufacturer shall not be responsible for any additional costs associated with a product failure including, but not limited to, loss of

work time, loss of refrigerant, cross-contamination of refrigerant, and unauthorized shipping and/or labor charges.

All warranty service claims must be made within the specified warranty period. Proof-of-purchase date must be supplied to the

manufacturer

Use of recovery/recycling equipment with unauthorized refrigerants or sealants will void warranty

Authorized refrigerants are listed on the equipment or are available through the Technical Service Department

This Limited Warranty does NOT apply if:

The product, or product part is broken by accident.

The product is misused, tampered with or modified.

The product is used for recovering or recycling any substance other than the specified refrigerant type.

MAINTENANCE AND CARE

PARTS LIST AND WARRANTY

Service Mode

This mode should only be entered with direction by technical support or by an authorized service center.  This mode enables the testing 

of each device controlled by the FX Series’ computer.  These devices include the ball valves, vacuum pump, compressor and pressure 

transducers.  This mode can be located in the “Maintenance Mode”
Field Software Update

Updates to the system software will require use of this mode.  Found in the “Maintenance Mode”, an update password and the new software 

file installed on a USB drive will be required.  Insert the USB stick with the new software update file into the USB port on the back of the 

control panel.  Go to the        and select        Follow the displayed directions.  Be sure power remains on during this operation.
Display Calibration

Under certain conditions the touch screen may lose its calibration (i.e., touches on the screen don’t result in the desired result).   If pressing 

a function on the screen does not actuate the function, or engages an adjacent function, the screen needs to be calibrated.  To do so, turn the 

machine’s power off.  Then while pressing and holding  any spot  on the touch screen turn the power back on.  A screen set up menu will be 

displayed.  Select screen calibration and follow the on-screen directions.

Part Number

Description

FX3030X1

FX Series Maintenance Kit—Filter, Vacuum Pump oil and Coupler O-rings

Buy locally

Printer Paper—2.25” x 50’ Thermal Sensitive Paper

QCL1234

Low Side 1234yf Coupler

QCH1234

High Side 1234yf Coupler

QCL134

Low Side R134a Coupler

QCH134

High Side R134a Coupler

AR2788X14B

¼ SAE/High Side R134a tank refill adapter

AR2788X14A

1/2 ACME High Side R134a tank refill adaptor

FA1233X35

1/2 ACME LH/High Side R1234yf tank refill adaptor

CRX400T

50lb Recovery Tank

481500

Oil Injection Kit - R-134a

481500yf

Oil Injection Kit - R1234yf

Содержание FX3030

Страница 1: ...ARGE UNIT OPERATION MANUAL Models FX3030 Covered under US Patent 8 082 750 and other patents pending Certified by ITS under J2911 to meet SAE J3030 for R 134a and R 1234yf Certified by ITS under SAE J2911 to meet high volt age compressor service per SAE J3030 ...

Страница 2: ...tion manual 1 Roll 2 25 x 50 Thermal Paper Built in Refrigerant Identifier 50lb DOT Tank Filter and Hose Sets for R134a Installed and R1234yf End user to provide Refrigerant oil dye injection system Refrigerant FX3030 Specifications Power 115V 60Hz 1Ph Compressor 2 3 HP Twin Cylinder Oil less Vacuum Pump 50 Micron Rated 6 CFM Gauges 3 5 Low side 30 in Hg to 250 psi High Side 0 to 600 psi Hoses 120...

Страница 3: ...he vicinity of spilled or open containers of gasoline or other flammable substances Make certain that all safety devices are functioning properly before operating the equipment CAUTION This equipment should be used in locations with mechanical ventilation that provides as least 4 air changes per hour CAUTION RISK OF INJURY the equipment should only be operated by certified personnel CAUTION Use on...

Страница 4: ... DRAIN OIL The DRAIN OIL icon notifies the user that oil is draining from the vehicle ERROR Displays when there is an ERROR F Tap to select FARENHEIGHT FAILED Indicates that a given operation FAILED FILTER Displays the current status of the filter life ICON NAME DESCRIPTION IMAGE FILTER CHANGE Displays when a filter change is required FILTER CHANGE Tap to CHANGE FILTER FILTER CHANGE Tap to CHANGE ...

Страница 5: ... Tap to perform full calibration SCALE ZERO Tap to RE ZERO the scale SERVICE Tap to select SERVICE SERVICE HOSES BEING FLUSHED Indicates that the SERVICES HOSES are BEING FLUSHED ICON NAME DESCRIPTION IMAGE SET TIME Tap to SET TIME SETTINGS Tap to launch the SETTINGS screen SETUP Tap to launch the SEUP menu SPEAKER Tap to enable sound START AC Notifies user to start vehicle and turn on AC during s...

Страница 6: ...print outs Pressing will cause the unit to proceed with set up without personalizing your unit Selecting will cause the unit to ask you later if you want personalize your FX3030 4 When personalization has been completed press OK and the unit will proceed through self calibration When complete the Home screen will appear 5 A NO PRESSURE DETECTED IN THE TANK message will appear Hit Continue to proce...

Страница 7: ...ay the amount recovered through out the process and at the end The ending amount may be printed by pressing the icon visible on the Home screen after recovery is completed Vacuum Select Vacuum if the vehicle system is void of refrigerant and is ready to be recharged Evacuating the vehicle utilizes the FX Series 6 CFM vacuum pump to pull air and boil moisture from the AC system A specific vacuum ti...

Страница 8: ...America The full cycle process begins with a refrigerant purity test and the vehicle system This is required for SAE2843 for R1234yf only If the system passes the purity test the machine will proceed with recovery The Full Cycle process continues after recovery with pre charge vacuuming and leak testing Leak testing is required under SAEJ2843 for R1234yf systems The system is first vacuumed After ...

Страница 9: ... to start the AC system You can then collect and print readings If you plan to recover next press the button You will be taken to the Home screen If all is well press and the machine will guide you through clearing the hoses of refrigerant back into the AC system Change Unit of Measure or Language Press the maintenance icon and select This will take you to a screen to allow you to select either or...

Страница 10: ...process Calibration requires a certified 25lb weight Pressure Transducer Maintenance Use this mode if you suspect that the internal pressure transducer readings are inaccurate The internal pressure transducers are used during recovery vacuum air purge and in the manifold mode To enter this mode press the maintenance icon Then select PT This will allow the transducer to be set or calibrated Calibra...

Страница 11: ...unauthorized refrigerants or sealants will void warranty Authorized refrigerants are listed on the equipment or are available through the Technical Service Department This Limited Warranty does NOT apply if The product or product part is broken by accident The product is misused tampered with or modified The product is used for recovering or recycling any substance other than the specified refrige...

Страница 12: ...ue providing any OEM proprietary data from the Databases in the event it is for any reason not available or in the event any OEM imposes commercially unreasonable fees or restrictions on use of such data 3 OWNERSHIP CONFIDENTIALITY You agree that the data contained in the Databases contain confidential information and that MOTOR or its licensing OEMs owns all rights in the Databases and the data c...

Страница 13: ...f Licensor or its agent s choice c No delay or failure by MOTOR to exercise or enforce at any time any right or provision hereof shall be considered a waiver thereof or of MOTOR s right thereafter to exercise or enforce each and every right and provision of this Agreement d If any provision hereof shall be held illegal invalid or unenforceable in whole or in part such provision shall be modified t...

Отзывы: