CR500 SERIES SPECIFICATIONS

CR500

CR500J

CR500S

Compressor Type

1/3 HP Oil-less Reciprocating Compressor

Dimensions

20cm (8”) wide x 37cm (14.5”) long x 30.5cm (12”) high

Weight

9.1 kg (20 lbs.)

Operating Temperature Range

0°C (32°F) to 49°C (120°F )

Power Source

115 VAC 50/60Hz 1Ph

100 VAC 50/60Hz 1Ph

220-240 VAC 50/60Hz 1Ph

Power Consumption

500 W

Suction Pressure Gauge

-30”hg vac to 500 psig

-0.1 -3.5 mPa

-30”hg vac to 500psig

Discharge Pressure Gauge

0 to 800 psig

0 -5.5 mPa

0 to 800 psig

Filtration

Cleanable 100-mesh screen integrated into Suction Port

Shut-off Valves

Both Suction and Discharge manifold ball valves

Construction

Heavy gauge aluminum chassis with High Density Polyethylene Case

Overload Protection

10A thermal circuit breaker

5A thermal circuit breaker

High Pressure Shut-off

550 psig

Refrigerants

R-12, R-134a, R-401C, R-406A, R-500, R-401A

R-409A, R-401B, R-412A, R-411A, R-407D, R-22

R-411B, R-502, R-407C, R-402B, R408A, R-509

R-407A, R-404A, R-402A, R-507, R-407B, R-410A

Flow Rate

Direct Vapor

Up to 1.00 lb./min

Direct Liquid

Up to 2.50 lb./min

Push-Pull Liquid

Up to 11.00 lb./min

Содержание CR500 Series

Страница 1: ...equipment has been certified by Underwriter Laboratories UL to meet or exceed EPA regulations per ARI 740 95 for refrigerants 12 134a 22 500 and 502 See Specifications for a complete list of refrigerants OPERATION MANUAL TO BE OPERATED BY QUALIFIED PERSONNEL ONLY ...

Страница 2: ...ry Additional features include EXTREMELY LIGHTWEIGHT unit weighs less than 20 lbs 9 1 kg HIGH PERFORMANCE integrated fan ON THE RUN SELF CLEARING VALVE No need to turn the unit off when switching from recovery to self clearing BUILT IN FILTER located under intake port No dangling filters to damage FILTER CARTRIDGE can be easily cleaned or replaced R 410A COMPATIBLE Special high pressure unit desig...

Страница 3: ... recover flammable refrigerants CAUTION all hoses may contain liquid refrigerant under pressure Contact with refrigerant may cause frostbite or other related injuries Wear proper personal protective equipment such as safety goggles and gloves When disconnecting any hose please use extreme caution CAUTION avoid breathing refrigerant vapors and or lubricant mist Exposure may irritate eyes nose throa...

Страница 4: ...ge 0 to 800 psig 0 5 5 mPa 0 to 800 psig Filtration Cleanable 100 mesh screen integrated into Suction Port Shut off Valves Both Suction and Discharge manifold ball valves Construction Heavy gauge aluminum chassis with High Density Polyethylene Case Overload Protection 10A thermal circuit breaker 5A thermal circuit breaker High Pressure Shut off 550 psig Refrigerants R 12 R 134a R 401C R 406A R 500...

Страница 5: ...covery Tank 3 Open DISCHARGE valve on CR unit 4 Rotate the center valve to the RECOVERY position 5 Turn power switch to ON position 6 Once unit has started open the SUCTION valve on the CR unit to start the refrigerant flow NOTE If liquid refrigerant is present a hammering sound will come from the compressor Use the SUCTION valve to meter or regulate the incoming refrigerant until the hammering so...

Страница 6: ...t as shown in Figure 1 2 Once loose remove the suction port filter cartridge assembly is shown in Figure 2 3 Either clean the current cartridge or replace with new cartridge Item NO CRXF3 4 Inspect O RING RE LUBRICATE with compressor oil or equivalent 5 Place filter back into suction port fitting 6 Hand tighten this assembly back onto the CR unit 7 Use a 7 8 socket or boxed end wrench to tighten 1...

Страница 7: ...t breaker Push the START switch PROBLEM The unit recovers at a very slow pace SOLUTION Check the suction port filter Replace or clean HELPFUL HINTS If the refrigerant to be recovered is from equipment with high contamination levels of acid moisture etc it is recommended to utilize an in line filter drier placed before the suction port of the CR600 unit An Alco EKO52 or equivalent filter drier woul...

Отзывы: