background image

AFM100 OPERATION

6

Initial Preparation:

Open drain valve on the back of the unit to empty 

Collection Tank

. This will 

  prevent overfilling of the collection tank which will lead to spillage of spent 
  solvent. Check sight glass for solvent level in the collection tank.

DO NOT

 connect an air supply hose to the unit at this time. 

CAUTION: The 

  pressure gauge must read 0 PSIG before removing the tank fill cap

. If pressure 

  exists close 

AIR SUPPLY

 valve and turn 

FLUSH VALVE

 to 

PURGE

/

OFF

 position. 

  This will relieve the pressure in the Flush Tank. 

Remove the flush tank Fill Cap by hand only. Add amount of CPS solvent to be 

  flushed through the A/C component. Maximum capacity of flush tank is 
  2.5 gallons. See following chart for flush amount to used: 

RECOMMENDED FLUSH SOLVENT AMOUNT PER VEHICLE:

 

 

CAR/PICKUP TRUCKS:     

2 Quarts

   

 

DUAL AIR SYSTEMS: 

 

3 Quarts

   

 

HEAVY DUTY TRUCKS: 

 

3 Quarts

   

 

BUSES/MOBILE HOMES etc: 

up to 2 Gallons

Once flush tank is filled to the desired amount with CPS solvent, reinstall cap. 

  Make sure the cap is hand tight. 

DO NOT USE A WRENCH TO TIGHTEN FILL CAP

.

Purge or Flow Verification Procedure:

Connect 

OUTLET HOSE A

 via connectors*/adaptors to the outlet of the component 

  to be flushed.

Connect 

INLET HOSE B

 via connectors*/adaptors to the inlet of the component to 

  be flushed. 

*CPS provides a set of Universal Clamps for this purpose. There 

  maybe other type of connectors or adaptors required.

1.

2.

3.

4.

1.

2.

FLUSH TANK

PRESSURE

WARNING

: DO NOT

REMOVE CAP UNLESS

GAUGE READS 0 PSIG

FLUSH

VALVE

FLOW DIRECTON

VALVE

REVERSE

FLUSH

FLUSH HOLD

FORWARD

PURGE

 

OFF

Содержание afm100 series

Страница 1: ...A C SOLVENT FLUSH For use with CPS SUPER FLUSH SOLVENT TO BE OPERATED BY QUALIFIED PERSONNEL ONLY OPERATION MANUAL ...

Страница 2: ...erating Range 0 C 32 F to 49 C 120 F Air Pressure Gauge 0 to 100 PSIG Filtration 100 mesh cleanable screen Manual Control Valves 2 way ball type valve to control air supply to the unit 3 way ball type valve to control air Purge Flush circulation 4 way ball type valve to control Forward and Reverse flush Construction Heavy duty power coated sheet metal cabinet with 6 wheels Adaptors One set of univ...

Страница 3: ...ol valve will allow the user to reverse the flow at any time The CPS Universal Flush clamps makes connecting to an A C component easy The following are additional features One set of CPS Universal Flush Clamps Easy one step hook up Air Hose and Flush Hoses Forward Reverse flush valve to eliminate reconnection of hoses Filter with clear removable bowl for flow and filtration verification Large mout...

Страница 4: ...reathing solvent vapor fumes Exposure may irritate eyes nose throat and skin Please read the manufacturers material safety data sheet for further safety information on the solvent CAUTION avoid skin contact with solvent Exposure may irritate eyes nose throat and skin Please read the manufacturers material safety data sheet for further safety information on the solvent Wear proper personal protecti...

Страница 5: ... unit not shown Hose storage hooks Outlet Hose A to component out fitting 6 wheels Handle Flow direction valve 1 2 3 4 5 6 7 Flush valve Outlet Hose B to component out fitting Clear bowl with cleanable filter Storage shelf Collection tank drain valve back side of unit not shown Collection tank sight glass right side of unit not shown Flush tank pressure gauge 8 9 10 11 12 13 14 1 2 3 4 5 6 7 9 10 ...

Страница 6: ... tank is 2 5 gallons See following chart for flush amount to used RECOMMENDED FLUSH SOLVENT AMOUNT PER VEHICLE CAR PICKUP TRUCKS 2 Quarts DUAL AIR SYSTEMS 3 Quarts HEAVY DUTY TRUCKS 3 Quarts BUSES MOBILE HOMES etc up to 2 Gallons Once flush tank is filled to the desired amount with CPS solvent reinstall cap Make sure the cap is hand tight DO NOT USE A WRENCH TO TIGHTEN FILL CAP Purge or Flow Verif...

Страница 7: ...r Bowl and both flush hoses Once CPS solvent is present in both hoses and is seen moving through the bowl turn the FLUSH VALVE to FLUSH HOLD position Hold for 10 15 minutes This allows the CPS solvent to dissolve contaminants Turn FLUSH VALVE back to FLUSH position Run for 1 2 minutes or until all the solvent has passed through the component To REVERSE FLUSH turn the FLOW DIRECTION VALVE to opposi...

Страница 8: ... Reinstall filter element and secure by screwing clear bowl back onto the filter housing Check the universal flush clamp for worn seals Check hoses for worn seals THE FOLLOWING ARE SERVICEABLE PARTS FOR THE AFM100 UNIT CPS Part Number Description AFMXH Flush hose with 3 8 female SAE swivel connection AFMXHS Flush hose rubber seal set of 2 AFMXF Replacement cylindrical filters AFMXC Replacement uni...

Отзывы: