AFM100 OPERATION
6
Initial Preparation:
Open drain valve on the back of the unit to empty
Collection Tank
. This will
prevent overfilling of the collection tank which will lead to spillage of spent
solvent. Check sight glass for solvent level in the collection tank.
DO NOT
connect an air supply hose to the unit at this time.
CAUTION: The
pressure gauge must read 0 PSIG before removing the tank fill cap
. If pressure
exists close
AIR SUPPLY
valve and turn
FLUSH VALVE
to
PURGE
/
OFF
position.
This will relieve the pressure in the Flush Tank.
Remove the flush tank Fill Cap by hand only. Add amount of CPS solvent to be
flushed through the A/C component. Maximum capacity of flush tank is
2.5 gallons. See following chart for flush amount to used:
RECOMMENDED FLUSH SOLVENT AMOUNT PER VEHICLE:
CAR/PICKUP TRUCKS:
2 Quarts
DUAL AIR SYSTEMS:
3 Quarts
HEAVY DUTY TRUCKS:
3 Quarts
BUSES/MOBILE HOMES etc:
up to 2 Gallons
Once flush tank is filled to the desired amount with CPS solvent, reinstall cap.
Make sure the cap is hand tight.
DO NOT USE A WRENCH TO TIGHTEN FILL CAP
.
Purge or Flow Verification Procedure:
Connect
OUTLET HOSE A
via connectors*/adaptors to the outlet of the component
to be flushed.
Connect
INLET HOSE B
via connectors*/adaptors to the inlet of the component to
be flushed.
*CPS provides a set of Universal Clamps for this purpose. There
maybe other type of connectors or adaptors required.
1.
2.
3.
4.
1.
2.
FLUSH TANK
PRESSURE
WARNING
: DO NOT
REMOVE CAP UNLESS
GAUGE READS 0 PSIG
FLUSH
VALVE
FLOW DIRECTON
VALVE
REVERSE
FLUSH
FLUSH HOLD
FORWARD
PURGE
OFF