IOM Manual: IOM-0000-CST IOM
Series CST: Submersible Turbine
01/01/2018 - Edition 1A
www.cps-pumps.com
PROBLEM
POSSIBLE CAUSE
RECOMMENDED REMEDY
Cont. Problem #3.0
No discharge or flow
3.2
Direction of rotation wrong.
After confirming wrong rotation,
reverse any two of three leads on a three
phase motor. The pump should be disas-
sembled and inspected before operation.
3.3
Plugged impeller, suction line or casing
which may be due to a fibrous product
or large solids.
Refer to recommended remedy under
Problem #1.0, Item #1.9.
3.4
Damaged pump shaft, impeller.
Replace damaged parts.
Problem #4.0
Pump operates for short period, then
loses prime.
4.1
Insufficient NPSH
A
.
Refer to recommended remedy under
Problem #1.0, Item #1.1.
4.2
Entrained air.
Air leak from atmosphere on suction
side. Refer to recommended remedy
under Problem #1.0, Item #1.1.
Problem #5.0
Excessive noise from wet end.
5.1
Cavitation - insufficient NPSH avail-
able.
Refer to recommended remedy under
Problem #1.0, Item #1.1.
5.2
Abnormal fluid rotation due to complex
suction piping.
Redesign suction piping, holder number
of elbows and number of planes to a
minimum to avoid adverse fluid rotation
as it approaches the impeller.
5.3
Impeller rubbing.
1. Replace impeller and/or case wear
rings.
2. Check outboard bearing assembly for
axial end play.
Problem #6.0
Pump will not run.
6.1
No power to control box.
Refer to ELECTRICAL TESTS
6.2
Motor protection device tripped.
Refer to ELECTRICAL TESTS
6.3
Blown fuse.
Refer to ELECTRICAL TESTS
6.4
Open circuit in cable, splice or motor
winding.
Refer to ELECTRICAL TESTS
6.5
Control box malfunction.
Refer to ELECTRICAL TESTS