background image

CPR Aquatic, INC•P.O. Box 1111•3749 West End Road, Arcata, CA 95521 

CPR’s Continuous Siphon Overflows provide the most efficient means of getting water to an external 
filter without expensive modifications to the tank.  These precision-engineered overflows skim water from 
the surface of your aquarium at flow rates up to six times greater than units with tubes.   Advantages 
such as water level adjustment, quiet operation, fish screen, and a black top to reduce algae growth all 
make the CPR Continuous Siphon Overflow the best on the market.  Please read through the set up 
directions before and during the actual set up to ensure it is done correctly. 
 
To place your overflow into operation: 
 
1.  Open the packaging carefully and inspect the unit for damaged or missing parts.  You should have: 

(1) Overflow body 
(1)  1 1/2” Bulkhead assembly 
(4) Adjustment screws 
(1) Airline 
(1)  Aqua Lifter pump and Acrylic Lid (included in Deluxe models) 

If any items are damaged or missing, please contact your dealer immediately. 
 
2.  Before using the overflow for the first time it is important to decide where to position the unit.  It is 

best to have the overflow as far away from the inflow as possible to reduce turbulence.  It is also 
important to check the capacity of your sump as well as the flow rate of your return pump on your 
filtration system to prevent possible overflow.  It will be necessary to add water to the system after 
it begins running.  The amount of water that you will need to add will depend on the sump size and 
design. 

 
3.  Assemble the bulkhead fitting as shown in diagram A.   

4.  Connect the bulkhead fitting to the hose going into your filtration system.  You should use 1 1/2” 

Schedule 40 PVC inserted into the bulkhead.  The PVC can be run directly into the filter or can be 
attached to flexible line using fittings.  The fewest bends in the line will ensure the quietest 
operation.  To prevent leaking from where the PVC inserts into the bulkhead, you should use PVC 
cement to secure it into place.   If using adapters other than PVC, All-Purpose Cement should be 
used to secure the plumbing in place. 

 
5.  Place the unit on the edge of your tank and allow the water to fill the front chamber.  Adjust the 

lower adjustment screws so that the unit is parallel to the back of the tank. 

 
6.  Adjust the height of the unit with the two top adjustment screws so the water level is about ¼” 

above the edge of the front chamber.(FIG 1)  Make sure that the overflow is level with the water 
surface, not necessarily the tank, as some tanks may not be perfectly level.   

 
 
 

CS150   

                 Continuous Siphon Overflow 

CPR Technical Support (707) 826-9636 • FAX (707) 826-9623 

www.cprusa.com • [email protected] 

Содержание CS150

Страница 1: ...k the capacity of your sump as well as the flow rate of your return pump on your filtration system to prevent possible overflow It will be necessary to add water to the system after it begins running The amount of water that you will need to add will depend on the sump size and design 3 Assemble the bulkhead fitting as shown in diagram A 4 Connect the bulkhead fitting to the hose going into your f...

Страница 2: ...ne to the nipple on the overflow and after drawing all the air out place the end of the airline into a sump which should be at least two feet below the overflow This method is not as effective as those above 8 When you initially start the siphon overflow it will drain water from your aquarium down to the level of the front edge of the overflow box The sump part of the filter should begin to fill w...

Страница 3: ...lushing or gurgling sound You may need to adjust the level of the tubing up or down to find the point where the air is vented Your overflow is now in operation The outside of your overflow may be cleaned with a non abrasive cloth Do not use detergent on any surface that comes into contact with aquarium water Note The CS150 does not include the sponge and vent tube seen in the diagrams below Fig 1 ...

Страница 4: ...gram B Inlet Outlet tubing to sump tank or overflow Air Nipple Aqua Lifter and lid included in Deluxe models Lid not shown Diagram A NOTE No slip screen vent tube or gear sponge is in cluded with the CS150 ...

Отзывы: