![CPI Talos T700 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/cpi/talos-t700/talos-t700_install-manual_2675006003.webp)
Configuration Coupons - Continued
Bezel LED Error Flash Codes
I
nsert the configuration coupon and verify the settings were accepted by counting the bezel flashes
Flashes
Meaning
10
Configuration coupon accepted and unit
successfully programmed.
1 - 5
Coupon rejected. Number of flashes corresponds
to the coupon section that was improperly filled
out. Try again.
7
Coupon not read. Confirm the coupon is
correct and try again.
When the unit is ready and enabled, the bezel LEDs will flash continuously. If the bezel LEDs are off, the unit has an error. To determine the error, partially insert
and hold a bill in the bill path until the bezel lights flash. Count the flashes and refer to the chart below.
Flashes
Problem
Solution
None
No power
Restore power to validator or machine
1 or 4
Bill path
blocked
Check for jams. Remove bill
magazine and lower housing
assembly and inspect
2
Another
vending
component
Ensure the unit has been enabled,
then check:
• Vending Machine Controller
• Coin manager and coin levels
• Inventory levels
• The door is locked properly
3
Lower
housing
assembly
Check that the lower housing
assembly is seated. Ensure bill path
is clean; see Cleaning section
5
Bill magazine
removed
Reattach bill magazine
Continuous
fast
Stacker full
Empty the bill magazine
Continuous
slow
Unit is
defective
Replace the unit
Talos Install Guide_Web_5.24.19.indd 3
5/24/2019 9:57:14 AM