E
XTERNAL
I
NTERFACES
D
OC
.01040045
R
EV
.6
3-5
Table 3-3. Discrete Output Faults and Alarms of J6
Alarm/Fault Alarm
Fault
Condition
Inactive
Relay is Inactive to Fault or Alarm
Summary Fault
X
Any Fault Condition
Summary Alarm
X
Any Alarm Condition
High RF Output Fault
X
Level User-defined
Low RF Output Fault
X
Level User-defined
High Reflected RF
U
U
Level User-defined under 45W
Over Temp Fault
X
Temperature >78 ºC
AC Fault
X
Module Fault or AC in <85VAC
Bias Fault
X
Negative Bias Voltage >-8V or Temp 80-
85ºC
High Drain Current
X
>120 A or 60 A (Factory Settable)
Note: Depending on model.
BUC Unlock
U
U
BUC LO loss of lock
Brick Comm. Fault
X
RF Brick will not communicate with M&C
High RF Warning
X
Level User-defined
Low RF Warning
X
Level User-defined
High Temp Alarm
X
User Settable (70 ºC default)
High Hot Spot Temp.
X
Hot Spot >~78 ºC
Low Drain Voltage
X
<9.6 V (Factory Settable)
High Drain Voltage
X
>10.6 V (Factory Settable)
BBRAM Bad
X
RAM not Battery Backed
PSU Diode Temp
Alarm
X
PSU Diode Temp > 95degC
PSU FET Temp Alarm X
PSU FET Temp > 97degC
FAN Tach Alarm
X
Fan speed < 90% of Average Fan speed
Note: X indicates Factory Set, U indicates user selectable as a Fault or
Alarm.
Содержание S4UIA
Страница 4: ...INDOOR SSPA IV DOC 01040042 REV 6 This page is intentionally left blank...
Страница 23: ...UNPACKING INSTALLATION DOC 01040044 REV 6 2 7 Figure 2 1 Connector Locations C band shown...
Страница 42: ...INITIAL POWER ON CHECKOUT 4 10 DOC 01040053 REV 6 This page is intentionally left blank...
Страница 52: ...OPERATION 5 10 DOC 01040086 REV 7 Figure 5 8 Setup 1 5 Figure 5 9 Setup 2 5 Figure 5 10 Setup 3 5...
Страница 66: ...OPERATION 5 24 DOC 01040086 REV 7 This page is intentionally left blank...
Страница 80: ...SSPA FUNCTIONAL TREE 7 2 DOC 01040089 REV 4 This page is intentionally left blank...
Страница 90: ...CUSTOMER WARRANTY AND SUPPORT A 2 APP 01040025 REV 1 This page is intentionally left blank...