effigis.com
CPAT FLEX (DRV3 Lite)
9
8
User Manual
Figure 1: DRV3 Lite portable dual-band signal leakage detection meter accessories
Part No.
Accessory Description
1
110-00005-001
AC adapter
2
008-00006-001
Battery pack
3
111-00031-001
Mid-band rubber duck antenna (SMA connector)
4
150-00033-001
DRV3 Lite leakage detection receiver
5
100-00009-001
DRV3 Lite User Manual
To order, please contact Effigis at + 1-888-495-6577 or + 1-514-495-0018
2.2 DRV3 Lite Settings Application
A DRV3 Lite Settings Application is available in order to configure the DRV3 Lite. This
PC-based software is used to configure several DRV3 Lite units with the same operational
parameters. You can download the latest version of the DRV3 Settings Application by visiting
our Web site:
http://effigis.com/cpat-flex-support/
. In order to use the DRV3 Lite Settings
Application, you will need to connect the DRV3 Lite to your PC via a Micro-B USB to a USB
cable or an USB-to-serial cable (cables not provided).
2.3 Features
The DRV3 Lite is a high-performance dual band find-and-fix leakage detection meter, which
offers many features including:
• Three functional modes:
1. ‘‘Pressure test’’ mode using the DSG1 Lite transmitter with mid-band and LTE
band frequency presets (126 and 612 MHz in Mid and LTE)
2. “System mode” detecting leakage carriers produced from the DSG1 signal
generator located at the headend. When operating in ‘‘system mode’’, the DRV3
Lite is fully agile from 118-140 MHz (Mid-band tuner) and 600-860 MHz (LTE
band tuner)
3. “Spectrum mode” is used for on-the-spot diagnosis by CPAT support team but
is also available for normal users. In this mode, the DRV3 Lite can work as a
simplified spectrum analyzer with a fixed 56KHz span and a configurable cen-
ter frequency. Both mid-band spectrum and LTE spectrum will be displayed on
screen. The DRV3 Lite can also display AM modulations from 3Hz to 110 Hz on
the chosen frequencies.
•
User-adjustable frequency displayed in 1 kHz steps
• Bluetooth and Micro USB connections
•
Multi-function button
•
Based on Effigis’s CPAT Flex leakage monitoring system technology
NOTE
Leakage detection is based on signal tag recognition to differentiate real signal
leakage from electrical noise. We must ensure that monitored frequencies are
tagged in order to detect signal leakage. Please review your documentation on
the DSG1 and DSG1 Lite module for more details on carrier tagging.
2.4 Physical Overview
2.4.1 Startup
When you press the on/off button (hold ~3 sec.), the DRV3 Lite begins to load its operating
software and parameters. During this process, the power light on the top left of the DRV3
Lite is orange (when charging battery) or green. The battery indicator light indicates powering
as follows:
Green
Battery fully charged
Orange
Battery discharged
Red
Indicates battery pack fault
1
2
3
4
5