Problem 

Cause 

Solution 

 

Air intake from the seal 

mechanical 

Replace the mechanical seal 

Excessive intervention of the 

thermal protection 

Not correct voltage 

Check the voltage present on the line 

(qualified technical personnel) 

The impeller is hindered in rotation 

Check the integrity of the 

impeller. Clean the impeller 

Defective capacitor 

Replace the capacitor 

Lack of water leakage in the 

first minute after starting 

Air infiltration in the suction pipe 

Check and if necessary repair the pipe, 

checking its hermetic seal 

The pump starts without 

water 

Water leakage from the pipeline o 
from the pump 

Repair the piping, pump or connecting 

points between parts 

Loss of water from the estate 

mechanics 

Replace the mechanical seal 

 

 

 

Insufficient flow of water 

Reached the level limit 

suction 

Check the water level in the suction basin 

Filter, pre-filter and / or valves 

clogged or blocked 

Verify clean / repair the components 

associated with the piping and the pump 

Impeller blocked 

Disassemble the pump and carefully 

clean the pump body and impeller 

(qualified personnel only) 

 

 

 

 

Failure to prime 

Presence of air 

Check the mechanical joint 

Transparent perforated plastic cover 

Clean the clear plastic cover and check 

the gasket 

Wrong motor direction 

Electrical check 

High absorption 

Adjust the absorption 

Wrong voltage 

Check the voltage of the power line 

No water in the filter basket or in the 

pump body 

Fill the filter basket or pump 

housing with water 

Absence of water for priming 

Fill the suction tube with water 

 

 

 

Little reach 

Presence of air 

Check that the lid is closed 

correctly 

Wrong motor direction 

Check the electrical wiring 

High absorption 

Adjust the absorption 

Wrong voltage 

Voltage check 

Blockage in the filter basket 

Clean the filter basket 

Dirt in the pump housing 

Clean the pump body 

The engine does not start 

and makes noise 

Impeller block 

Impeller washing 

Water leaks in 

function 

Damage to the mechanical seal or 

dirt absorbed by it 

Clean the mechanical seal or change it 

 

NOTE 

 

 

CPA srl excludes any liability for non-compliance with the safety standards in force for the individual technical sectors affected by this 

document. 

 

The information contained in this manual may vary at the discretion of the editor, without notice, together with the changes  to the product in 

question in this document: it will be the responsibility of the customer to verify the persistent correspondence of the product to the information 
sheet when placing the order. 

Содержание AMBRA

Страница 1: ...MANTEINANCE MANUAL Ver 01 2021 06 18 Read carefully AMBRA Circulation water pump...

Страница 2: ...p body cover and diffuser made of high quality plastic material Motor shaft in AISI 316 stainless steel Excellent and long lasting mechanical seal Seal support made of glass and polyamide Windings imp...

Страница 3: ...2870 17 8 23 16 AMBRA 150M 230 50 6 1 1 5 1 1 2880 20 8 25 18 25 AMBRA 150T 400 50 2 7 3 1 5 1 1 2880 20 8 25 18 AMBRA 200M 230 50 7 1 2 1 5 2880 22 10 28 20 30 AMBRA 200T 400 50 3 1 3 2 1 5 2880 22...

Страница 4: ...ith the installation check that the moving parts rotate freely insert a screwdriver into the recess of the motor shaft on the side of the fan protection grid and try to rotate the blades fig C If the...

Страница 5: ...the formation of air pockets It is recommended to use a non return valve between the delivery port and the flow control valve in order to avoid dangerous water hammer in the event of a sudden stop of...

Страница 6: ...f an accidental dry start immediately disconnect the power supply then wait for the engine to cool and then fill it with clean water Start the pump and check in the three phase version that the direct...

Страница 7: ...lso recommended for long periods of inactivity in normal temperature conditions After a long period of inactivity repeat all the operations described for the first start up PROBLEMS AND SOLUTIONS Prob...

Страница 8: ...ce of air Check the mechanical joint Transparent perforated plastic cover Clean the clear plastic cover and check the gasket Wrong motor direction Electrical check High absorption Adjust the absorptio...

Отзывы: