PILOT FLAME
ADJUST-
MENT

Pilot flame
should
envelop
 3/8 to 1/2
 inch on the
 tip of the
generator.

FIGURE 2

RADIANTS AND GLASS PANELS

FOR ALL VCR MODELS

(See Figure 9 – Replacement Parts Section)

INSTALL GLASS AND RADIANTS AS FOLLOWS:

STEP 1

. Remove three screws from under top of opening in

bezel frame assembly.

STEP 2

. Pull top of bezel down and lay aside.

STEP 3

. Remove glass from bottom pad in shipping carton.

STEP 4

. Remove carton containing radiants from cavity of

combustion chamber.

STEP 5

. Remove radiants from carton and install by tilting

backwards and lifting at the same time into opening.  Place
the radiants on the burner radiants supports.  The radiants
must be straight.  Never operate heater if any radiant is
broke or tilted to front or rear.

Continued

STEP 6

. Install glass panels by inserting top edge into upper

retainer and lower into bottom support, and slide glass into
position.  Do not allow a crack between the two glass panels.
Never operate heater with either glass missing or cracked.

STEP 7

. Re-install bezel by placing bezel tabs over lower front

and swing bezel into position and secure with three screws.

MAIN BURNER ORIFICE

This appliance was shipped from the factory with an orifice
sized to give the correct gas input using the gas for which the
heater was equipped.  There may be local conditions, such as
variation in gas supply pressure or BTU content of the gas,
which may be cause for a change in the orifice.  The gas
company supplying the fuel or the installing contractor should
check the gas input rate.

If the rate exceeds the “BTUH INPUT” on the rating plate by
5%, the orifice must be replaced with a smaller orifice by a
qualified service technician to reduce the input to the rating
plate value.

The input rate will need to be adjusted for elevation above
2,000 Feet.  See the following charts to determine the correct
orifice size for your Model Number and elevation.  These
orifice sizes are based on a heating value of 1020 for Natural
Gas and 2500 for L.P. Gas.

CAUTION

:  As elevation increases, derating is necessary for

the safe and proper operation of this heater.  Do not increase
the Btu input rate by increasing the orifice size or gas
pressure.  Allow for elevation derating when sizing gas heating
equipment.

SPECIFIC ELEVATIONS

Model        0 to      2,000-      4,000 -      6,000 -      8,000’
 No.        2,000’      4,000’     6,000’       8,000’     10,000’
VC201         45

      47             48              49

 50

VC351         35              37             38              40

 42

VC501         30

      31             31              32

 35

VC701         25

      27             28              29

 30

VCR351       35

      37             38              40

 42

VCR501       30

      31             31              32

 35

VCR701       25

      27             28              29

 30

ORDER KIT #49820  45-1 HIGH ALTITUDE KIT

SPECIFIC ELEVATIONS

Model        0 to       2,000-

    4,000 -        6,000 -        8,000’

No.          2,000’      4,000’         6,000’        8,000’       10,000’
VC202     1.3mm

       55

          56            56

57

VC352    1.65mm        53

          53            54

54

VC502         47

       49

          49            50

51

VC702         41

       42

          43            44

46

VCR352   1.65mm        53

          53            54

54

VCR502      47

       49

          49            50

51

VCR702      41

       42

          43            44

46

ORDER KIT #49820  45-1 HIGH ALTITUDE KIT

NATURAL GAS

L.P. GAS

Page 8

3/8 TO
1/2 INCH

FIGURE 1

PILOT ADJUSTMENT

The pilot flame can be observed by opening the pilot lighting
hole cover.  The pilot flame should surround the top 3/8 to ½
inch of the pilot generator (see Figure 2).  If the flame needs
adjusting, first locate the pilot adjustment screw cap and remove.
Adjustment screw is underneath (see Figure 1).  To increase the
flame, turn the pilot adjustment screw counterclockwise          .
To decrease the flame, turn the screw clockwise           .  NOTE:
The pilot is unregulated.  If incoming line pressure is more than
7” w.c. Natural Gas or 11” w.c. for L.P. Gas, the pilot flame size
should be decreased.

Pilot Adj. Screw

Содержание VC201B-D

Страница 1: ...gency MR MRS HOMEOWNER DO NOT attempt any of these procedures yourself as this could expose you to property damage personal injury or loss of life and will invalidate all warranties INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference The coating selected to provide longer life to the heat exchanger may smoke slightly upon initial firing Provide adequate ...

Страница 2: ...tandards are available from International Approval Services 178 Rexdale Boulevard Etobicoke Ontario Canada M9W 1R3 The design of this appliance was certified to comply with the latest edition of ANSI Z21 86 and CSA 2 32 Installer must leave these instructions with the consumer have them complete and return the warranty card ROOM HEATER SPECIFICATIONS Your room heater comes packed in a single carto...

Страница 3: ...h when activated will extinguish the burner flame If the homeowner experiences this problem the vent system must be checked and corrected NOTE An existing vent that has worked for years may not be adequate for todays design because of higher efficiency requirements resulting in lower stack temperatures The following is a list of possible causes and corrective actions POSSIBLE CAUSES CORRECTIVE ACT...

Страница 4: ...extends more than five 5 feet above roof See Termination diagram above Firestop Support Assembly VerticalVent Elbow Listed Appl Terminate vent at least 5 ft above draft hood CONNECTING THE VENT INTO AN EXISTING CHIMNEY SAFE See Venting NOTE Thismayresult intheventsafetyswitch shuttingdowntheburner dependingonsizeand drawofchimney NOT RECOMMENDED FIGURE7A 1 4 UNSAFE Do not installin thismanner FIGU...

Страница 5: ...t test pressure in excess of psig Theappliancemustbeisolatedfromthegassupply pipingbyclosingitsindividualmanualshutoffvalve duringanypressuretestingofthegassupplypiping systemattestpressuresequaltoorlessthan psig LOCATIONAND SPECIAL PRECAUTIONS Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Childrenandadultsshouldbealertedtothehazards ...

Страница 6: ... spaces cannot be blocked with insulation or other objects Each of these openings using vertical ducts shall have a minimum free area of one square inch per 4 000 btu hr of total input rating of all gas appliances See Figure B and C If horizontal ducts are used the minimum free area shall be one square inch per 2 000 btu hr of total input rating of all gas appliances Fresh make up air can also be ...

Страница 7: ...tions such as a mantle or window sill is 22 on the 20 35 and 19 inches on the 50 70 models with a maximum horizontal extension of 18 inches The clearances around the air opening into the combustion chamber must be maintained and the burner must be kept clean Do not permit dust or dirt to accumulate here The other clearances previously mentioned must be maintained There must be adequate room provid...

Страница 8: ...er orifice by a qualified service technician to reduce the input to the rating plate value The input rate will need to be adjusted for elevation above 2 000 Feet See the following charts to determine the correct orifice size for your Model Number and elevation These orifice sizes are based on a heating value of 1020 for Natural Gas and 2500 for L P Gas CAUTION As elevation increases derating is ne...

Страница 9: ...e 8 Clean the rear chamber by using bottlebrush through the vent tube openings 9 Replace combustion chamber burner and control Check all gas piping for leaks before lighting heater Repair service must be performed by a qualified service technician The heater should be inspected before initial use An annual cleaning of control compartment and safety performance check must be made by a qualified ser...

Страница 10: ...art of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the information on the safety label 2 Turn temperature control knob to OFF or it s lowest position 3 Depress and turn gas control knob clockwise to OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the informa...

Страница 11: ...an burner ports do not enlarge ports 3 Low gas pressure 3 Check gas supply pressure See Gas Supply 4 Pilot decreases in size when main 4 Supply piping is inadequately sized Consult local gas burners come on utility or competent installer 5 Drafts around unit 5 Eliminate drafts 6 Pilot lighter door open causing 6 Close pilot lighter door disturbance of pilot flame 7 Improper venting 7 See Venting P...

Страница 12: ... POOR HEATING RESULTS Cont d Burner won t light 1 Pilot flame too large or too small 1 Re adjust pilot flame using adjustment on combination control valves See Fig 1 1A 2 Defective combination control valve 2 Replace valve Pilot outage 1 Dirt in pilot orifice 1 Clean pilot orifice with air or solvent do not ream 2 Pilot lighter door open 2 Close pilot lighter door 3 Defective automatic pilot secti...

Страница 13: ...e heater base Secure the blower to the base with two 8 screws provided See figure A STEP6 Connect black wire from junction box to right fan switch terminal See Figure B STEP7 Connect white wire from junction box to white fan motor wire See Figure B STEP8 Connect black wire from fan motor to left fan switch terminal See Figure B STEP9 Turn variable speed control switch clockwise as viewed from fron...

Страница 14: ... leavingitsendconnectedtotheblockedflueswitchandleavingenoughlengthtoreach the gas valve Strip 1 2 of the insulation from the cut end of the wire STEP 5 Connect one leg of thermostat wire to the TH PP terminal on the gas valve STEP 6 Connect second leg from the thermostat to the stripped wire coming from the blocked flue switch Secure this connection inside the heater cabinet STEP 7 Secure both re...

Страница 15: ...salers but the prices listed are for your convenience For prompt parts service contact the wholesaler from which you purchased your Cozy heater NOTE Parts schematic drawings on current models are shown at www cozyheaters com NOTICE When ordering any component in the control train assembly specify either Dexen Honeywell or Robertshaw components 43 51 47 44 46 50 45 49 42 48 21 33 25 29d 35 36 29b 2...

Страница 16: ......

Страница 17: ...ate the installer the user should write directly to the manufacturer and the name of an alternative service source will be supplied The product safety registration card packed inside the appliance must be completed and returned to the factory THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED WHETHER WRITTEN OR ORAL ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS F...

Отзывы: