DEFINITIVE SOCKET FABRICATION
1.
Place Small Integrator™ in desired location on mold and trace location
2.
Pull PVA bag over mold. Using heat ensure edge of PVA bag is within the inner diameter of the Small Integrator™.
3.
Carefulle glue Small Integrator™ to mold and PVA bag.
4. Place in alignment fixture and attach alignable connector at desired alignment. Remove from fixture.
5. Lay up as normal reinforcing between connector posts.
6.
Tie Lay up into the tie in ring in the Small Integrator™.
7. Install Five Hole Plate using provided screws.
8. From here socket is laminated in preferred fashion.
9. Remove Five Hole Plate. Finish Socket as usual.
Quick Adhesive will NOT stick to Small Integrator™ permanently
For further fabrication and connector options see back page
Results can only be guaranteed if Coyote® Quick Adhesive is used
This piece of paper is NOT packing material. It is
instructions for the product also enclosed in the package.
These instructions could be helpful in fabricating and
using the product correctly. We recommend reading them
BEFORE using.
If you have more questions please call
Coyote at (208) 429-0026.
You can also visit coyotedesign.com and check out
fabrication videos on:
•
Attaching the Alignable Connector
•
Fabricating the check socket
•
Fabricating the definitive socket
1
2
4.
5.
PARTS IN THIS PACKAGE