background image

www.coyoteoutdoor.com

C

2

SL3

0

 

INSTALL GUIDE

10 1/4"

OPENING

HEIGHT

DOORS / DRAWERS 

OPENING WIDTH

20 1/2"

OPENING

DEPTH

OPENING

HEIGHT

GRILL

OPENING

GRILL

OVERHANG

TOP VIEW

OPENING WIDTH

2 1/2"

OPENING

HEIGHT

DOORS / DRAWERS 

OPENING WIDTH

OPENING

DEPTH

OPENING

HEIGHT

24"

LINER

OPENING

7/8"

JACKET

OVERHANG

TOP VIEW

OPENING WIDTH

24"

FRONT VIEW

FRONT VIEW

1 1/2" MIN

INCLUDING 

COUNTERTOP

Combustible material can not be within 24" of the grills frame

This applies to all directions - horizontal & vertical

Shaded area above on "TOP VIEW" illustrates the 24" minimum

requirement (not to scale for rendering purposes)

The grill is designed to hang from the counter top with no support

underneath

Minimum rear clearance for the hood to open is 2"

If you have a wall/partition behind the grill, the minimum rear clearance

to that wall should be at least 7" to allow for ventilation of the exhaust

24"

If using combustible material within 24" of the grill frame, you MUST use

the corresponding Coyote Insulated Jacket

Using a insulated jacket, does not waive any other standard installation

procedure (ventilation, connections, etc)

The jacket is designed to hang from the counter top with no support

underneath

Minimum clearance for hood to open is 2"

If you have a wall/partition behind the grill, the minimum rear clearance

to that wall should be at least 7" to allow for ventilation of the exhaust

Ventilation Requirements:

 

Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within

the island.

These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.

For a propane setup, the vents should be installed lower as propane is heavier than air.

For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.

Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped

gas to dissipate.

1

 

1/2"

1

 

5/8"

1

 

1/2"

22

 

1/8"

1 1/2" MIN

7/8"

11"

INCLUDING 

COUNTERTOP

3

0

 3/

4

"

1

 

3/4"

2 1/2"

21/2"

2"

G

GAS

CONNECTION

G

4 1/8"

4 1/8" 

G

GAS

CONNECTION

4 1/8"

G

2 3/4"

Important Note to Installer: 

This file is not intended to replace your Owners' Manual which contains specific safety

requirements and consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in grill.

NON-COMBUSTIBLE CONSTRUCTION

Insulated Jacket NOT Required

COMBUSTIBLE CONSTRUCTION

Insulated Jacket Required - Model # CJAKTC

S3

0

27"

Отзывы: