11
valve knob counterclockwise (right to left). If you hear a rushing sound, turn gas off immediately. There is a
major leak at the connection. Correct before proceeding by calling the Coyote Customer Service line at
855-520-1559.
7. If no rushing sound, brush soapy solution onto areas where bubbles are shown in LP tank (see picture).
8. If “growing” bubbles appear, there is a leak. Close LP tank valve immediately and retighten connections. If
leaks cannot be stopped, do not try to repair the regulator, or tank valve, by yourself and contact the Coyote
Customer Service line at 855-520-1559.
9. Always close LP tank valve after performing leak test by turning cylinder valve knob clockwise.
NOTE:
When leak testing this appliance, make sure to test and tighten all loose connections. A slight leak in the
system can result in a low flame, or a hazardous condition that could result in a fire or explosion.
LP Gas Supply Cylinder Disconnection
In order to disconnect the LP tank from the side burner:
1.
Turn the burner valves off.
2.
Turn the tank valve off. (Turn shut-off clockwise to stop).
3.
Detach the regulator assembly from the tank valve by turning the quick coupling nut counterclockwise.
LP Tank Removal, Transport and Storage
-
Turn OFF all control knobs and LP tank valve. Turn coupling nut counterclockwise by hand only - do not use
tools to disconnect. Install safety cap onto LP tank valve. Always use cap and strap supplied with valve.
Failure to use safety cap as directed may result in serious personal injury
and/or property damage.
A disconnected LP tank in storage or being transported must have
a
safety cap
installed (as shown).
-
Never leave a LP tank inside a motor vehicle. (Heating of the
vehicle could cause an increase in the gas pressure which may
open the release vale allowing gas to escape resulting a serious
risk of fire or explosion.)
-
Do not store an LP tank in enclosed spaces such as a carport,
garage, porch, covered patio or other building.
-
Do not store LP tank in an area where children play.
LP Tank Filling
-
Use only licensed and experienced LP dealers.
-
LP dealer must purge tank before filling.
-
Dealer should NEVER fill LP tank more than 80% of LP tank volume. Volume of propane in tank will vary by
temperature.
-
A frosty regulator indicates gas overfill. If frosty, immediately close LP tank valve and call local LP gas dealer
for assistance.
-
Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice.
-
To remove gas from LP tank, contact an LP dealer or call a local fire department for assistance.
LP Tank Exchange