11

 

valve knob counterclockwise (right to left). If you hear a rushing sound, turn gas off immediately. There is a 
major leak at the connection. Correct before proceeding by calling the Coyote Customer Service line at 
855-520-1559.   

7.  If no rushing sound, brush soapy solution onto areas where bubbles are shown in LP tank (see picture). 
8.  If “growing” bubbles appear, there is a leak. Close LP tank valve immediately and retighten connections. If 

leaks cannot be stopped, do not try to repair the regulator, or tank valve, by yourself and contact the Coyote 
Customer Service line at 855-520-1559. 

9.  Always close LP tank valve after performing leak test by turning cylinder valve knob clockwise.       

 

NOTE: 

When leak testing this appliance, make sure to test and tighten all loose connections. A slight leak in the 

system can result in a low flame, or a hazardous condition that could result in a fire or explosion.   

LP Gas Supply Cylinder Disconnection 

In order to disconnect the LP tank from the side burner: 
1.

 

Turn the burner valves off.   

2.

 

Turn the tank valve off. (Turn shut-off clockwise to stop).   

3.

 

Detach the regulator assembly from the tank valve by turning the quick coupling nut counterclockwise.   

LP Tank Removal, Transport and Storage 

Turn OFF all control knobs and LP tank valve. Turn coupling nut counterclockwise by hand only - do not use 
tools to disconnect. Install safety cap onto LP tank valve. Always use cap and strap supplied with valve. 

 

Failure to use safety cap as directed may result in serious personal injury 

and/or property damage. 

A disconnected LP tank in storage or being transported must have 

safety cap

 installed (as shown).   

Never leave a LP tank inside a motor vehicle. (Heating of the 

vehicle could cause an increase in the gas pressure which may 
open the release vale allowing gas to escape resulting a serious 
risk of fire or explosion.)   

Do not store an LP tank in enclosed spaces such as a carport, 
garage, porch, covered patio or other building.   

Do not store LP tank in an area where children play. 

LP Tank Filling 

Use only licensed and experienced LP dealers. 

LP dealer must purge tank before filling. 

Dealer should NEVER fill LP tank more than 80% of LP tank volume. Volume of propane in tank will vary by 
temperature. 

A frosty regulator indicates gas overfill. If frosty, immediately close LP tank valve and call local LP gas dealer 
for assistance. 

Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice. 

To remove gas from LP tank, contact an LP dealer or call a local fire department for assistance.   

LP Tank Exchange 

Содержание C1CSB-2LP

Страница 1: ...bling grill Leave this manual with grill for future reference To consumer Keep this manual for future reference as it contains important Warnings and Instructions COYOTE OUTDOOR LIVING INC Coyote Stai...

Страница 2: ...y your new side burner and thank you for choosing our product We hope you consider us for future purchases Read and save the instructions Obey all Warnings and Instructions This Manual provides specif...

Страница 3: ...l not be stored in the vicinity of this or any other appliance DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury CAUTION CAUTION ind...

Страница 4: ...specified clearances listed in this Manual on page 9 7 NEVER leave the side burner unattended while cooking 8 Risk of Explosion NEVER use natural gas in a unit designed for liquid propane gas or vice...

Страница 5: ...o the rack located just under the side burner 25 Fire Hazard Grease is extremely flammable Let hot grease cool down before attempting to handle or dispose of it After use and cool down the drip tray s...

Страница 6: ...rust or burn through 5 years limited Flavorizer Bars no rust or burn through 2 years limited Ignition systems Valves 1 year limited Stainless steel frame housing Limited Lifetime Coyote Outdoor Living...

Страница 7: ...ice or damages caused by flashback fire or grease fire This limited warranty does not cover scratches dents corrosion or discoloration caused by weather heat abrasive and chemical cleaners pool or spa...

Страница 8: ...the side burner in a building garage breezeway shed or other such enclosed areas without an approved ventilation system When in use the side burner will generate a lot of smoke When installing your s...

Страница 9: ...M and CSA Z240 RV Series Recreational Vehicle Code as applicable Gas valves are preset at the factory to operate on liquid propane or natural gas If you wish to convert be sure to contact your side bu...

Страница 10: ...seal has been obtained The cylinder must be arranged for vapor withdrawal It must also include a collar to protect the cylinder valve A safety relief device having direct communication with the vapor...

Страница 11: ...or safety relief valve You may damage the valve and cause a leak Leaking propane may result in explosion fire severe personal injury or death 2 If a leak is detected at any time or you cannot stop a...

Страница 12: ...kwise LP Tank Removal Transport and Storage Turn OFF all control knobs and LP tank valve Turn coupling nut counterclockwise by hand only do not use tools to disconnect Install safety cap onto LP tank...

Страница 13: ...y company However it is the responsibility of the owner installer to verify that the correct regulator is purchased for the intended application and that it is installed properly o As codes vary from...

Страница 14: ...result in a low flame or a hazardous condition that could result in a fire or explosion Natural Gas Supply and Connection 1 Make sure all burner valves are in the OFF position 2 All NG units need to...

Страница 15: ...e grill when lighting ALWAYS inspect the hose before using the grill If there is excessive abrasion or wear or if the hose is cut it must be replaced prior to the outdoor cooking gas appliance being p...

Страница 16: ...then to your valve and finally into the burner where it will meet the spark from the igniter at the front of the burner Conversely if you turn the knob too slowly you can cause a build up of gas in t...

Страница 17: ...utensils used to handle raw food before using them to handle cooked food Always wash all vegetables seafood and poultry before cooking Always leave uncooked foods in the refrigerator until you are rea...

Страница 18: ...cleaned periodically to prevent buildup of debris NOTE Allow the drip tray to cool before attempting to clean IMPORTANT Do not leave the side burner outside during inclement weather unless it is cove...

Страница 19: ...ner to cool before cleaning polishing stainless steel Do not clean or polish your side burner s stainless steel when the gill is in operation or still hot 2 To clean the stainless steel wash off all d...

Страница 20: ...tub 4 Do not store pool chemicals in your island or island cabinets How to Remove Scratches from your Stainless Steel If your situation is a little more serious and you have obtained scratches in your...

Страница 21: ...d other flammable vapors and liquids 2 Do not obstruct the flow of combustion and ventilation air 3 Keep the ventilation opening s of the cylinder enclosure free and clear from debris 4 Visually check...

Страница 22: ...ts contact our Coyote Customer Service line at 855 520 1559 Problem Possible Causes and Solutions Burner will not light when the igniter button is turned Is your gas supply turned on If this is an L P...

Страница 23: ...lve is open and cylinder has fuel Low heat with the knob on HIGH Check to see if the fuel hose is bent or kinked Make sure the cooking area is clear of dust Check your gas supply and gas pressure If i...

Страница 24: ...Knob base 1 CICSB12 3 Burner 1 CICSB03 13 knob 1 CICSB13 4 Electrode 1 CICSB04 14 Control Panel 1 CICSB14 5 Burner box CICSB05 15 Logo Badge 1 CICSB15 6 Gas hose 1 CICSB06 16 LP Regulator 1 CICSB16 7...