Страница 2: ...stening firmly the power supply line to the terminal Faulty connection may causer unexpected damage or fire To Install Warnings Use adaptors included in the package to protect the camera If you use th...

Страница 3: ...rol OSD menu 10 6 1 How to control OSD menu 14 6 2 DISPLAY Tab 14 6 3 VIDEO SIZE Tab 20 6 4 VIDEO Tab 22 6 5 IMAGE ADJUSTMENT Tab 26 6 6 NUC Tab 28 6 7 NETWORK Tab 30 6 8 ALARM OUTPUT Tab 33 6 9 CORRE...

Страница 4: ...trol Using jog switch on the rear of camera user can control menu very easily while user sees monitor In case thermal camera is integrate into a certain system user can control OSD menu via RS485 apar...

Страница 5: ...re included in the package when user open packaging for the first time If any of following components is not included contact distributor supplied COX camera to you Cables BNC Giga Ethernet cable User...

Страница 6: ...ual 3 Names of camera external parts Camera case lens mount body top bottom end cap Lens Power socket for lens motors for focus and zoom CVBS composite video output BNC port 12 VDC power in Micro HDMI...

Страница 7: ...Manual 4 Connectors controls and indicators CVBS composite video output port BNC 12VDC power in Micro HDMI Digital I O ports 1 2 3 4 5 6 7 RS 485 N A ALARM 1 ALARM 2 RS 485 RS 485 SW1 NO SW1 COM SW2...

Страница 8: ...to CVBS video from BNC port How to connect Ethernet cable 1 connect RJ45 Ethernet cable included in the package to RJ45 port on the rear of the camera Initial IP address setting It is set at DHCP mode...

Страница 9: ...ontrol by jog switch Refer to page 16 of this manual to know how to use jog switch For control via IP network refer to thermal imaging analyzer or camera controller on CD included in the package Contr...

Страница 10: ...ure parts are in black If there are any IR ray reflective objects humans can not recognized in the area of image it will make image in the monitor much different from what user expects 5 Looking at th...

Страница 11: ...FF ON TEMPERATURE OFF ON ROI OFF EMPTY RECTANGLE FILLED RECTANGLE CORRECTION INFO OFF ON TRANSPARENCY OFF 20 40 60 80 TEMPERATURE UNIT CELSIUS FAHRENHEIT VIDEO SIZE NTSC WIDTH 600 720 Used to set size...

Страница 12: ...IMAGE ADJUSTMENTS AGC MODE AUTO MANUAL MANUAL MAX 0 16383 Activated when set at MANUAL MANUAL MIN 0 16383 Activated when set at MANUAL NOISE FILTER OFF NR1 NR2 NR1 NR2 NR1 2 STRENGTH HIGHEST HIGH MID...

Страница 13: ...YPE NO NC A01 MODE OFF READY FOR USE ALIVE PWM TEMPERATURE REMOTE CONTROL TEST ALARM ON TEST ALARM OFF A01 DURATION 0 99 A02 TYPE NO NC A02 MODE OFF READY FOR USE ALIVE PWM TEMPERATURE TEST ALARM ON T...

Страница 14: ...IGHT 400 576 720p 50Hz WIDTH 1100 1280 HEIGHT 600 720 720p 60Hz 1080I 50Hz WIDTH 1700 1920 HEIGHT 900 1080 1080I 60Hz 1080P 50Hz 1080P 60HZ PROTOCOL PELCO D COX ID 0 0 255 BAUDRATES 2400 4800 9600 192...

Страница 15: ...nd OSD menu is display in the monitor as follows Move to the menu using Left Right Up Down function of jog switch Menu selected shall be highlighted If jog switch is pressed values or status user can...

Страница 16: ...ture unit Connection of HDMI and network Alarm ON Display all icons OFF Not display those icons Camera ready for normal use ON Show 3 steps of stabilization in red yellow and blue color Blue color dis...

Страница 17: ...DMI icon Display if connection to Micro MDMI port on the rear of the camera is done Connected to HDMI port is not done Connection to HDI port is done Network icon Display if camera is connected to the...

Страница 18: ...perature spot COLD in the image OFF Not display HOT spot and COLD spot COLOR BAR Show color bar beside image ON On the left COLOR BAR is displayed OFF Does not use COLOR BAR display TEMPERATURE displa...

Страница 19: ...age EMPTY RECTANGLE Show ROI in the type of empty rectangle FILLED RECTANGLE Show ROI in the type of filled rectangle ROI Rectangle or Spot will not be displayed on video output OF CVBS or HDMI if the...

Страница 20: ...affect temperature measurement Those parameters must be set for accuracy in measurement ON On the bottom left EMISSIVITY TRANSMISSION transmission rate of atmosphere ATMOSPHERE AMBIENT TEMPERATRUE are...

Страница 21: ...fferences 20 CG320 CG640 Manual 40 60 80 TEMPERATURE UNIT Set unit of temperature CELSIUS Set unit of temperature at Celsius FAHRENHEIT Set unit of temperature at Fahrenheit F 6 3 VIDEO SIZE Tab Set s...

Страница 22: ...or range of input value NTSC PAL HEIGHT Set height of NTSC or PAL video output Refer to the table below for range of input value Video format selected Width Height NTSC 600 720 400 480 PAL 600 720 400...

Страница 23: ...ion Refer to the table below for range of input value at given resolution Video output mode Width Height 480p 600 720 400 480 576p 600 720 400 576 720p 50Hz 1100 1280 600 720 720p 60Hz 1080I 50Hz 1700...

Страница 24: ...fferences 23 CG320 CG640 Manual BRIGHTNESS Default value 0 User can set brightness in the range of 40 40 CONTRAST Default value 0 User can set contrast in the range of 10 10 ZOOM User can set digital...

Страница 25: ...rature and temperature differences 24 CG320 CG640 Manual ROTATION User can rotate or flip video MIRROR Change the side left and right of the image Mirror Off Mirror On FLIP Make video upside down Flip...

Страница 26: ...25 CG320 CG640 Manual M F Execute MIRROR and FLIP at the same time M F off M F On PALETTE User can select different type of color palettes GREY IRON RAINBOW GREY RED GLOWBOW YELLOW MID GREY INVERT Re...

Страница 27: ...uitable value AUTO Automatically adjust the input to output gain brightness of image MANUAL Set value of gain manually In MANUAL setting image become to be terribly bright or dark if not properly set...

Страница 28: ...Decrease noise in the image NR1 Apply built in NOISE FILTER1 to decrease FIXED PATTERN NOISE NR2 Apply built in NOISE FILTER2 to decrease GAUSSIAN NOISE NR1 NR2 Apply both NOISE FILTER1 and NOISE FIL...

Страница 29: ...LTER is applied and sharpen edges of objects OFF Not use EDGE FILTER EE STRENGTH Adjust strength of EDGE FITER LEVEL 0 LEVEL 6 6 6 NUC Tab The non uniformity is a time dependent noise caused by the la...

Страница 30: ...nce manually whenever push jog switch upward or downward NUC MODE Set mode of NUC OFF Not execute NUC TIME Execute NUC at set time interval AUTO The camera executes NUC automatically by itself by dete...

Страница 31: ...SH Set sensitivity of NUC when AUTO MODE is selected Set sensitivity in 5 steps HIGHEST HIGH MIDDLE LOW and LOWEST The higher sensitivity means the shorter time interval in NUC 6 7 NETWORK Tab Set par...

Страница 32: ...F when not connected LINK SPEED Show network atmosphere when camera is connected to the network 0MB DUPLEX NONE When camera is not connected to the network 100MB DUPLEX FULL When camera is connected t...

Страница 33: ...P ADDRESS Set IP address when DHCP is set at OFF NETMASK Set NETMASK Set Netmask when DHCP is set at OFF GATEWAY Set GATEWAY Set Gateway when DHCP is set at OFF NETWORK APPLY Apply set parameters of n...

Страница 34: ...Set various parameters of alarm signal camera outputs A01 02 TYPE Set type of alarm signal Normal Open or Normal Close If NO is selected When there is no alarm output is 0 When there is alarm output...

Страница 35: ...rval of 100msec Example TEMPERATURE Execute alarm as per alarm settings set using Camera Controller which is one of PC software included in the COX camera package REMOTE CONTROL Use alarm set by Therm...

Страница 36: ...CTION Tab Set emissivity transmission ambient temperature atmosphere in overall image temperature correction parameter ZERO OFFSET and correction by distance from camera to the object USED Set if CORR...

Страница 37: ...ambient temperature Set value 50 0 100 0 ZERO OFFSET Set temperature correction parameters In case camera always give temperature data a certain degrees higher or lower than real temperature set tempe...

Страница 38: ...ject to get more accurate measured value Generally speaking camera gives lower temperature of the same object as camera moves away from the object DISTANCE correction is up to 25m because measuring te...

Страница 39: ...s between 0 and 500 If COX camera is delivered with high temperature detection mode user can select NORMAL or HIGH mode dual mode depending on temperature measurement range NORMAL normal temperature d...

Страница 40: ...0Hz 1080p 60Hz When HDMI Mode is changed the camera shall be disconnected from the network and reboot automatically PROTOCOL Select PROTOCOL for RS485 communication Select one of PELCO D and COX PROTO...

Страница 41: ...485 communication it is necessary to assign different ID for each camera BAUDRATE Set Baud rate in RS485 communication 2400 4800 9600 19200 38400 57600 115200 MOTORIZED FOCUS Adjust focus or zoom of l...

Страница 42: ...the OSD menu MOTORIZED ZOOM Control zooming in case camera is paired with zoom lens Push jog switch upwards move to TELE or downwards move to WIDE to change focal length zooming If the camera is not p...

Страница 43: ...Small menu Remark DISPLAY DISPLAY ICON ON CENTER OFF INDICATOR ON COLOR BAR OFF TEMPERATURE OFF ROI OFF CORRECTION INFO OFF TRANSPARENCY OFF TEMPERATURE UNIT CELSIUS VIDEO SIZE NTSC PAL WIDTH NTSC PA...

Страница 44: ...WORK DHCP ON IP ADDRESS NETMASK GATEWAY NETWORK APPLY RUN ALARM OUTPUT A01 02 TYPE NO A01 02 MODE OFF A01 02 DURATION 1 CORRECTION USED ON EMISSIVITY 0 95 TRANSMISSION 1 00 ATMOSPHERE 20 0 ZERO OFFSET...

Страница 45: ...after power supply If ambient temperature is too low it will take some time to start After storing for a long time in very low temperature near 30 it will take some time about 30 minutes to work norma...

Страница 46: ...ture range for example between 15 and 25 to have better accuracy in temperature measurement in case camera is installed in the open air Temperature detection mode Normal temperature detection mode 20...

Страница 47: ...as corresponds to strategic goods which are under control in export and import by international agreement and customers must get export license first from local relevant government organization before...

Страница 48: ...perature and temperature differences 47 CG320 CG640 Manual 11 Dimensional drawing CG320 or CG640 with 35mm f1 0 motorized lens Size of camera case for CG320 and CG640 is identical They use the same ca...

Страница 49: ...ssivity in the LWIR area 0 9 or higher However most metals have a low emissivity less than 0 6 with surface finish The higher the glare on the surface the lower the emissivity Heat that is not absorbe...

Страница 50: ...ings as well as factors such as the material of the object and the distance to the camera Reflections and material properties can affect temperature How well you know emissivity is important for your...